Skip to main content
Lab Manufacturers China
High-Content Screening Imaging System — product photo

High-Content Screening Imaging System

高内涵筛选成像系统

  • SKU CEI-0004
  • Cell Imaging
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • IEC 60825-1 laser safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Plate formats6 to 1,536-well plates and flasks
Imaging channels4–8 fluorescence plus brightfield
Light sourcesLED or laser, 365–740 nm options
Objective set2x to 60x with autofocus
Throughputthousands to tens of thousands of images per day
AutofocusImage-based or hardware, per well
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 60825-1, IEC 61010-1, IEC 61010-2-010

What is the High-Content Screening Imaging System?

A high-content screening imaging system automates plate handling, autofocus, multi-channel image acquisition and analysis, extracting quantitative single-cell features from thousands of wells for compound screening, dose-response studies and phenotypic assay development in drug discovery.

What is the High-Content Screening Imaging System?

A high-content screening imaging system automates plate handling, autofocus, multi-channel image acquisition and analysis, extracting quantitative single-cell features from thousands of wells for compound screening, dose-response studies and phenotypic assay development in drug discovery.

Overview

The platform combines a motorised stage with plate and flask carriers, multiple excitation lasers or LEDs, several emission channels, confocal or widefield optics and a fast camera. A plate map defines wells, fields and channels, and autofocus runs per well so that data quality is consistent across the plate. Image analysis can be performed on the fly or offline, with segmentation algorithms that identify nuclei, cytoplasm and organelles, then compute per-cell measurements such as intensity, area, shape, texture, spot count and distance between objects. Population statistics are aggregated per well for dose-response fitting. Typical throughput is thousands to tens of thousands of images per day, and the same data can be re-analysed with new algorithms, which makes the platform valuable for retrospective studies.

How does it work?

All cell imaging systems collect light from a specimen and form an image on a detector. In widefield microscopy, the whole field is illuminated and the image is limited by out-of-focus light, so thin cells look sharp while thick specimens appear hazy. Confocal microscopy places a pinhole in front of the detector so that only light from the focal plane reaches it, and it scans point by point or line by line to build an optical section; this improves contrast and allows three-dimensional reconstruction. Fluorescence excitation comes from LEDs, lasers or arc lamps, and dichroic mirrors and emission filters separate the excitation from the emitted signal. Live-cell systems add an incubated stage or chamber to hold temperature, CO2 and humidity, and software captures time-lapse sequences. High-content systems combine automated plate handling, autofocus and image analysis to extract numerical features from thousands of images.

What are the key features?

  • Automated plate and flask handling with defined plate maps
  • Per-well autofocus for consistent data across the plate
  • Four or more imaging channels with confocal or widefield optics
  • Segmentation-based single-cell feature extraction
  • On-the-fly or offline analysis with reusable algorithms
  • Dose-response fitting from aggregated population statistics

What are the technical specifications?

A typical high-content screening imaging system configuration offers plate formats of 6 to 1,536-well plates and flasks, imaging channels of 4–8 fluorescence plus brightfield, light sources of LED or laser, 365–740 nm options, objective set of 2x to 60x with autofocus, throughput of thousands to tens of thousands of images per day and autofocus of Image-based or hardware, per well. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The High-Content Screening Imaging System is used in compound library screening, dose-response and cytotoxicity profiling, phenotypic assay development and neurite outgrowth and organoid morphometry. Across the wider Cell Imaging class, laboratories also deploy it for cell morphology and confluence assessment, immunofluorescence and protein localisation and live-cell dynamics and time-lapse studies.

Which standards and certifications apply?

Relevant standards and methods include IEC 60825-1, IEC 61010-1, IEC 61010-2-010, ISO 17025 and ISO 20387. Certification candidates for this model are CE, ISO 9001 manufacturing, IEC 61010-1 safety and IEC 60825-1 laser safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Optical cleanliness is essential, so objectives should be cleaned with lens tissue and the recommended solvent, and immersion oil removed after every session. Live-cell imaging requires careful control of temperature, CO2 and humidity, because evaporation changes osmolarity and focus drift spoils long time-lapse runs; hardware autofocus or a focus-maintenance routine is usually needed. Phototoxicity and photobleaching limit live experiments, so use the lowest illumination power and shortest exposure that gives an acceptable signal, and reduce the number of channels and time points. Laser systems fall under IEC 60825-1 and must remain interlocked. After installation, verify alignment with a calibration slide, then check stage repeatability and focus stability periodically, and keep records so that images from different sessions remain comparable.

How do I select the right High-Content Screening Imaging System?

Select a high-content system when assays must be imaged and quantified at plate scale with reproducible settings. Specify plate formats, channel count, objective range, throughput, incubation capability, and the segmentation and analysis software, which determines what features can be extracted.

How does it compare with other Cell Imaging variants?

Match the system to the spatial and temporal resolution the experiment needs. Routine morphology, transfection checks and immunofluorescence on coverslips are well served by an inverted fluorescence microscope with LED illumination and a scientific camera. Confocal systems are needed when optical sections, thick specimens, three-dimensional reconstruction or low background matter, and spinning-disk confocals add speed for live imaging. Live-cell work requires an incubation chamber with CO2 and temperature control, plus low phototoxicity and a camera sensitive enough to limit exposure. High-content platforms are chosen when hundreds to thousands of wells must be imaged and quantified automatically. Check objective quality and numerical aperture, available fluorescence channels, detector sensitivity, stage automation, autofocus reliability, incubation performance and the analysis software, which often matters more than optics for quantitative results.

Full specifications

Full specifications
Plate formats6 to 1,536-well plates and flasks
Imaging channels4–8 fluorescence plus brightfield
Light sourcesLED or laser, 365–740 nm options
Objective set2x to 60x with autofocus
Throughputthousands to tens of thousands of images per day
AutofocusImage-based or hardware, per well
IncubationControlled temperature, CO2 and humidity
AnalysisSegmentation, per-cell features, population statistics
Data outputPlate-level CSV with per-cell feature tables
Dimensions (W x D x H)approx. 900 x 700 x 700 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Compound library screening
  • Dose-response and cytotoxicity profiling
  • Phenotypic assay development
  • Neurite outgrowth and organoid morphometry

Key features

  • Automated plate and flask handling with defined plate maps
  • Per-well autofocus for consistent data across the plate
  • Four or more imaging channels with confocal or widefield optics
  • Segmentation-based single-cell feature extraction
  • On-the-fly or offline analysis with reusable algorithms
  • Dose-response fitting from aggregated population statistics

Frequently asked questions about High-Content Screening Imaging System

Throughput depends on channels, magnification and wells per plate; a 96-well plate with four channels at 20x typically takes 20–60 minutes, so 15–30 plates per day are realistic on a well-configured system.

Related models

All Cell Imaging
Fluorescence Cell Imager — product photo

Fluorescence Cell Imager

荧光细胞成像仪

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the High-Content Screening Imaging System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote