Confocal Laser Scanning Microscope
激光共聚焦显微镜
- SKU CEI-0002
- Cell Imaging
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- IEC 60825-1 laser safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Laser lines | 405, 488, 561 and 640 nm typical |
|---|---|
| Scanning | Galvanometer mirrors, up to 512 x 512 at 4 fps |
| Detection | Spectral detector or filter-based photomultipliers |
| Pinhole range | 1–5 Airy units adjustable |
| Lateral resolution | approx. 200 nm lateral, 500 nm axial |
| Imaging depth | approx. 50–150 µm in cleared or sparse tissue |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 60825-1, IEC 61010-1, IEC 61010-2-010
What is the Confocal Laser Scanning Microscope?
A confocal laser scanning microscope uses a pinhole and scanning laser beams to reject out-of-focus light, producing optical sections through thick cells and tissue and enabling high-contrast three-dimensional reconstruction of subcellular structures.
What is the Confocal Laser Scanning Microscope?
A confocal laser scanning microscope uses a pinhole and scanning laser beams to reject out-of-focus light, producing optical sections through thick cells and tissue and enabling high-contrast three-dimensional reconstruction of subcellular structures.
Overview
The microscope focuses laser light to a point in the specimen and collects emitted fluorescence through a pinhole placed at the conjugate image plane, so light from outside the focal plane is largely rejected. Galvanometer mirrors scan the beam across the sample to build an image, and the operator can move the focal plane in defined steps to record a z-stack. A spectral detector or a set of filters separates several fluorophores, and objectives with high numerical aperture give lateral resolution near or below the optical diffraction limit. Typical usable depth is 50–150 µm in cleared or sparse tissue. Confocal imaging improves contrast and signal-to-noise compared with widefield, but requires higher light doses, so it is used for fixed samples and for short live-cell acquisitions.
How does it work?
All cell imaging systems collect light from a specimen and form an image on a detector. In widefield microscopy, the whole field is illuminated and the image is limited by out-of-focus light, so thin cells look sharp while thick specimens appear hazy. Confocal microscopy places a pinhole in front of the detector so that only light from the focal plane reaches it, and it scans point by point or line by line to build an optical section; this improves contrast and allows three-dimensional reconstruction. Fluorescence excitation comes from LEDs, lasers or arc lamps, and dichroic mirrors and emission filters separate the excitation from the emitted signal. Live-cell systems add an incubated stage or chamber to hold temperature, CO2 and humidity, and software captures time-lapse sequences. High-content systems combine automated plate handling, autofocus and image analysis to extract numerical features from thousands of images.
What are the key features?
- Pinhole-based optical sectioning with adjustable section thickness
- Galvanometer scanning for z-stacks and three-dimensional reconstruction
- Three to five laser lines with spectral or filter-based detection
- High numerical aperture objectives for diffraction-limited resolution
- Hybrid or photon-counting detectors for dim samples
- Incubation option for limited live-cell confocal work
What are the technical specifications?
A typical confocal laser scanning microscope configuration offers laser lines of 405, 488, 561 and 640 nm typical, scanning of Galvanometer mirrors, up to 512 x 512 at 4 fps, detection of Spectral detector or filter-based photomultipliers, pinhole range of 1–5 Airy units adjustable, lateral resolution of approx. 200 nm lateral, 500 nm axial and imaging depth of approx. 50–150 µm in cleared or sparse tissue. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Confocal Laser Scanning Microscope is used in subcellular localisation and co-localisation studies, thick tissue and three-dimensional reconstruction, organoid and spheroid internal structure imaging and quantitative fluorescence intensity measurement. Across the wider Cell Imaging class, laboratories also deploy it for cell morphology and confluence assessment, immunofluorescence and protein localisation and live-cell dynamics and time-lapse studies.
Which standards and certifications apply?
Relevant standards and methods include IEC 60825-1, IEC 61010-1, IEC 61010-2-010, ISO 17025 and ISO 20387. Certification candidates for this model are CE, ISO 9001 manufacturing, IEC 61010-1 safety and IEC 60825-1 laser safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Optical cleanliness is essential, so objectives should be cleaned with lens tissue and the recommended solvent, and immersion oil removed after every session. Live-cell imaging requires careful control of temperature, CO2 and humidity, because evaporation changes osmolarity and focus drift spoils long time-lapse runs; hardware autofocus or a focus-maintenance routine is usually needed. Phototoxicity and photobleaching limit live experiments, so use the lowest illumination power and shortest exposure that gives an acceptable signal, and reduce the number of channels and time points. Laser systems fall under IEC 60825-1 and must remain interlocked. After installation, verify alignment with a calibration slide, then check stage repeatability and focus stability periodically, and keep records so that images from different sessions remain comparable.
How do I select the right Confocal Laser Scanning Microscope?
Select a confocal microscope when optical sectioning, three-dimensional structure or low-background imaging is required for fixed or short-live acquisitions. Specify laser lines, detector type, pinhole range, objective set, scanner speed and whether a spectral detector or live-cell incubation is needed.
How does it compare with other Cell Imaging variants?
Match the system to the spatial and temporal resolution the experiment needs. Routine morphology, transfection checks and immunofluorescence on coverslips are well served by an inverted fluorescence microscope with LED illumination and a scientific camera. Confocal systems are needed when optical sections, thick specimens, three-dimensional reconstruction or low background matter, and spinning-disk confocals add speed for live imaging. Live-cell work requires an incubation chamber with CO2 and temperature control, plus low phototoxicity and a camera sensitive enough to limit exposure. High-content platforms are chosen when hundreds to thousands of wells must be imaged and quantified automatically. Check objective quality and numerical aperture, available fluorescence channels, detector sensitivity, stage automation, autofocus reliability, incubation performance and the analysis software, which often matters more than optics for quantitative results.
Full specifications
| Laser lines | 405, 488, 561 and 640 nm typical |
|---|---|
| Scanning | Galvanometer mirrors, up to 512 x 512 at 4 fps |
| Detection | Spectral detector or filter-based photomultipliers |
| Pinhole range | 1–5 Airy units adjustable |
| Lateral resolution | approx. 200 nm lateral, 500 nm axial |
| Imaging depth | approx. 50–150 µm in cleared or sparse tissue |
| Objectives | 10x to 100x with numerical aperture up to 1.4 |
| Z-step resolution | 10 nm minimum |
| Imaging modes | Fluorescence, reflection, optional transmitted light |
| Dimensions (W x D x H) | approx. 600 x 900 x 600 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Subcellular localisation and co-localisation studies
- Thick tissue and three-dimensional reconstruction
- Organoid and spheroid internal structure imaging
- Quantitative fluorescence intensity measurement
Key features
- Pinhole-based optical sectioning with adjustable section thickness
- Galvanometer scanning for z-stacks and three-dimensional reconstruction
- Three to five laser lines with spectral or filter-based detection
- High numerical aperture objectives for diffraction-limited resolution
- Hybrid or photon-counting detectors for dim samples
- Incubation option for limited live-cell confocal work
Frequently asked questions about Confocal Laser Scanning Microscope
In cleared tissue or sparsely labelled samples it reaches 50–150 µm, and less in dense material because scattering and absorption reduce signal. Two-photon or light-sheet systems extend depth considerably but are separate instrument types.
A smaller pinhole improves optical sectioning and contrast but lets less light reach the detector and increases noise. Most work uses 1 Airy unit as a balance, with smaller settings for high-resolution z-stacks.
Yes, for short acquisitions and with low laser power, preferably on a spinning-disk system that scans faster and reduces photodamage. Long time-lapse confocal runs usually damage cells, so widefield or light-sheet imaging is preferred for those experiments.
Confocal is needed when out-of-focus light obscures the signal, for example in thick specimens, three-dimensional reconstructions, thick tissue and sections with high background. For thin cultured cells and bright markers, widefield imaging with a good camera is often sufficient.
An incubation chamber maintaining 37 °C, CO2 and humidity, hardware autofocus to correct focus drift, and low illumination intensity to keep phototoxicity acceptable. Objectives with a long working distance also help when using thick culture vessels.
Use the lowest light intensity and shortest exposure that still gives adequate signal, reduce the number of fluorescence channels and time points, choose fluorophores excited by longer wavelengths, and use widefield or spinning-disk systems where confocal illumination would be excessive.
Related models