Low-Range Turbidity Meter for Pharmaceutical and Filtered Water

药用及过滤水低量程浊度计

  • SKU TUM-0002
  • Turbidity Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measuring range0–40 NTU
Resolution0.001 NTU
Accuracy±2% of reading or 0.005 NTU
Stray light≤0.005 NTU
Light sourceLaser diode, 660 nm, or LED, 860 nm
Detection angle90° ratio
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7027-1, USEPA Method 180.1, GB/T 13200

What is the Low-Range Turbidity Meter for Pharmaceutical and Filtered Water?

A low-range turbidity meter is optimized for clear liquids below 10 NTU, with stray light under 0.01 NTU and 0.001 NTU resolution. It is the suitable instrument for filtered drinking water, purified water and injectable solutions where subtle changes in clarity matter.

What is the Low-Range Turbidity Meter for Pharmaceutical and Filtered Water?

A low-range turbidity meter is optimized for clear liquids below 10 NTU, with stray light under 0.01 NTU and 0.001 NTU resolution. It is the suitable instrument for filtered drinking water, purified water and injectable solutions where subtle changes in clarity matter.

Overview

The low-range turbidity meter uses a laser diode or high-intensity LED, a precisely machined optical chamber and a sensitive 90° detector to measure very low scattering levels. A 0–40 NTU range with resolution of 0.001 NTU and accuracy of ±2% of reading or 0.005 NTU, whichever is greater, suits filtered water, pharmaceutical purified water and final rinse solutions. Stray light is typically below 0.005 NTU, and calibration with 0.02, 10 and 20 NTU standards is used. Sample cells are flat-bottom, indexed and carefully matched to limit background. Fine particle monitoring can follow the clarity trend after a filter to detect breakthrough. Because results depend strongly on vial cleanliness, an optional vial washer and dedicated vial sets are commonly specified. The instrument is not intended for heavily turbid samples, where a wide-range model is more appropriate.

How does it work?

A turbidity meter directs a beam of light through a sample and measures the portion scattered by suspended particles. In nephelometry the detector sits at 90° to the incident beam, and the signal is proportional to particle concentration within the linear range. Tungsten lamps at 400–600 nm are described in USEPA Method 180.1 and reported in NTU, while infrared LEDs at 860 nm are specified in ISO 7027 and reported in FNU. Ratio designs combine the 90° signal with transmitted and forward-scatter detectors to compensate for color and lamp drift. Calibration uses formazin or stabilized polymer standards such as 0.1, 20, 100 and 800 NTU. Some beverage instruments add a 25° detector to measure beer haze in EBC units, because larger particles scatter predominantly forward.

What are the key features?

  • Laser or high-intensity LED source improves sensitivity to low scattering levels.
  • Stray light below 0.005 NTU supports reliable readings near the detection limit.
  • 0.001 NTU resolution resolves subtle filter breakthrough trends.
  • Matched flat-bottom indexed sample cells limit background scatter.
  • Low-level calibration with 0.02 NTU primary standard.
  • Trend graph and alarm limit for filtrate monitoring.

What are the technical specifications?

A typical low-range turbidity meter for pharmaceutical and filtered water configuration offers measuring range of 0–40 NTU, resolution of 0.001 NTU, accuracy of ±2% of reading or 0.005 NTU, stray light of ≤0.005 NTU, light source of Laser diode, 660 nm, or LED, 860 nm and detection angle of 90° ratio. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Low-Range Turbidity Meter for Pharmaceutical and Filtered Water is used in purified and injection water clarity, filter breakthrough detection, final rinse solution verification and drinking water filtration studies. Across the wider Turbidity Meters class, laboratories also deploy it for filtered beverage and beer haze testing, pharmaceutical water clarity control and drinking water and wastewater monitoring.

Which standards and certifications apply?

Relevant standards and methods include ISO 7027-1, USEPA Method 180.1, GB/T 13200, Standard Methods 2130 B, ASBC Beer-9 and EBC Method 9.29. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Use clean, scratch-free and indexed sample vials, and wipe them with lint-free cloth and a thin film of silicone oil to hide minor imperfections. Degas samples and avoid bubbles, which produce false high readings. Calibrate with fresh formazin or certified stabilized standards, following the manufacturer's sequence, and verify with a secondary gel standard daily. Keep the optical chamber free of condensation by allowing cold samples to reach room temperature. Replace tungsten lamps according to hours of operation. Document calibration and verification records for GLP or ISO 17025 laboratories, and dispose of formazin according to local regulations because it contains hydrazine sulfate.

How do I select the right Low-Range Turbidity Meter for Pharmaceutical and Filtered Water?

Select the low-range turbidity meter when results below 1 NTU must be reliable, for example in pharmaceutical water or membrane filtration studies. It is less suitable for samples above 40 NTU. In an RFQ, specify range, stray light, light source wavelength, reporting unit, sample cell type and audit trail requirements.

How does it compare with other Turbidity Meters variants?

Choose a turbidity meter by measuring range, regulatory method, sample type and portability. Low-level clarity work below 1 NTU, such as filtered pharmaceutical water, requires a ratio benchtop instrument with stray light below 0.01 NTU and a resolution of 0.001 NTU. Wide-range industrial samples up to 4000 NTU suit a robust ratio design. Choose a white-light instrument for USEPA reporting and an infrared instrument for ISO 7027 compliance and colored samples. Beverage laboratories need EBC or ASBC units and a 25° channel. Field work favors portable, battery-powered models with IP67 housing. Online measurement needs a bubble trap and automatic cleaning. Specify vial or flow-cell format, calibration standards supplied and data output requirements.

Full specifications

Full specifications
Measuring range0–40 NTU
Resolution0.001 NTU
Accuracy±2% of reading or 0.005 NTU
Stray light≤0.005 NTU
Light sourceLaser diode, 660 nm, or LED, 860 nm
Detection angle90° ratio
Repeatability±1% of reading
Calibration standards0.02, 10, 20 NTU
Sample cellIndexed flat-bottom, 25 mm
Data outputUSB, printer, audit trail

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Purified and injection water clarity
  • Filter breakthrough detection
  • Final rinse solution verification
  • Drinking water filtration studies

Key features

  • Laser or high-intensity LED source improves sensitivity to low scattering levels.
  • Stray light below 0.005 NTU supports reliable readings near the detection limit.
  • 0.001 NTU resolution resolves subtle filter breakthrough trends.
  • Matched flat-bottom indexed sample cells limit background scatter.
  • Low-level calibration with 0.02 NTU primary standard.
  • Trend graph and alarm limit for filtrate monitoring.

Frequently asked questions about Low-Range Turbidity Meter for Pharmaceutical and Filtered Water

It combines a high-intensity laser or LED source, tightly controlled optical geometry and very low stray light, typically under 0.005 NTU. This lets it resolve scattering from trace particles that a general-purpose instrument would register as noise.

Related models

All Turbidity Meters