Skip to main content
Lab Manufacturers China
Manual Visual Polarimeter — product photo

Manual Visual Polarimeter

手动目视旋光仪

  • SKU POL-0003
  • Polarimeters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measurement range±180° optical rotation
Scale resolution0.05° (vernier)
Accuracy±0.05°
Light sourceSodium lamp or LED with 589 nm filter
Wavelength589 nm
Tube length100 mm and 200 mm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <781>, Ph. Eur. 2.2.7, JP 2.49

What is the Manual Visual Polarimeter?

A manual visual polarimeter requires the operator to match the brightness of a split field through an eyepiece and read the angle on a circular scale with a vernier. It is a low-cost option for teaching laboratories and infrequent, low-precision checks of sugars and other optically active solutions.

What is the Manual Visual Polarimeter?

A manual visual polarimeter requires the operator to match the brightness of a split field through an eyepiece and read the angle on a circular scale with a vernier. It is a low-cost option for teaching laboratories and infrequent, low-precision checks of sugars and other optically active solutions.

Overview

The manual polarimeter uses a sodium lamp or filtered white light, a polarizer with a half-shadow device, a sample compartment and a rotating analyzer read through a magnifier. The operator turns the analyzer until the two halves of the field have equal brightness, then reads the angle from the scale with a typical resolution of 0.05° using a double vernier. No electronics are required beyond the lamp, so it is robust and inexpensive. Accuracy depends on operator skill, ambient light and eye fatigue, and repeated readings are normally averaged. There is no temperature control, and temperature must be corrected using tables. Manual instruments are not recommended for regulated pharmaceutical release testing, but they remain useful for demonstrating Biot's law in education, field checks of sugar cane juice, and simple process screening.

How does it work?

A polarimeter passes monochromatic light, usually from a sodium D line source at 589.3 nm or an LED with a filter, through a polarizer, a sample tube and an analyzer. An optically active sample rotates the plane of polarization by an angle proportional to path length, concentration and specific rotation, following Biot's law. Manual instruments rely on the operator matching a split field visually, while automatic instruments use a Faraday modulator or a rotating analyzer with a photodetector to find the null position. Temperature strongly affects rotation, so many models include a thermostatted sample chamber, often Peltier controlled to 20.0 °C or 25.0 °C. Results are reported as optical rotation in degrees, specific rotation, concentration, or sugar scale such as °Z or ISS. Some models add multiple wavelengths to allow measurement of optical rotatory dispersion.

What are the key features?

  • Half-shadow polarizer gives a sensitive visual end point for trained operators.
  • Double vernier scale reads to 0.05° without electronics.
  • Sodium lamp or filtered source provides monochromatic 589 nm illumination.
  • Simple mechanical design tolerates handling in teaching environments.
  • Standard 100 mm and 200 mm tubes fit the sample compartment.
  • Low purchase and maintenance cost suits infrequent use.

What are the technical specifications?

A typical manual visual polarimeter configuration offers measurement range of ±180° optical rotation, scale resolution of 0.05° (vernier), accuracy of ±0.05°, light source of Sodium lamp or LED with 589 nm filter, wavelength of 589 nm and tube length of 100 mm and 200 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Manual Visual Polarimeter is used in education and demonstration of optical activity, sugar cane and syrup field checks, occasional screening of chiral solutions and low-volume research laboratories. Across the wider Polarimeters class, laboratories also deploy it for pharmaceutical QC of chiral drug substances, sugar and syrup concentration testing and essential oil and flavor purity checks.

Which standards and certifications apply?

Relevant standards and methods include USP <781>, Ph. Eur. 2.2.7, JP 2.49, ICUMSA GS2/3-1, OIML R 14 and GB/T 613. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the polarimeter on a vibration-free bench away from direct sunlight and strong electromagnetic fields. Allow the light source to warm up for 15–30 minutes before use. Verify performance with certified quartz control plates or a sucrose solution at defined concentration, and record results in the calibration log. Keep sample tubes clean and free of air bubbles, as bubbles cause unstable readings. Replace tube windows and seals when scratched or leaking. Confirm temperature at the sample, not only at the chamber setpoint. For regulated work, ensure 21 CFR Part 11 compatible software, scheduled calibration against traceable standards and documented installation and operational qualification.

How do I select the right Manual Visual Polarimeter?

Select the manual visual polarimeter for teaching or low-cost screening where ±0.05° accuracy and operator-dependent readings are acceptable. It is not suited to high-throughput or regulated release testing. In an RFQ, specify lamp type, tube lengths, scale resolution, power supply voltage and whether a demonstration teaching kit with quartz plates is needed.

How does it compare with other Polarimeters variants?

Choose a polarimeter by the required accuracy, measurement wavelength, temperature control and regulatory context. Pharmacopoeial testing of drug substances needs an automatic instrument with readability of 0.001° or better, Peltier control within ±0.1 °C and audit-trail software. Sugar and food quality control can use a saccharimeter with an ICUMSA-traceable scale and tolerates ±0.01° accuracy. Manual instruments suit teaching and low-volume checks where budget dominates. Samples that are dark or turbid need a polarimeter with high light throughput and short tubes. Chiral detection in chromatography requires a flow-through cell with a small volume. Also specify tube lengths, including 100 mm and 200 mm, sample volume and whether multiple wavelengths such as 436 nm or 546 nm are required for research work.

Full specifications

Full specifications
Measurement range±180° optical rotation
Scale resolution0.05° (vernier)
Accuracy±0.05°
Light sourceSodium lamp or LED with 589 nm filter
Wavelength589 nm
Tube length100 mm and 200 mm
Half-shadow angle2–5° (adjustable)
Eyepiece magnification4× reading magnifier
Warm-up time10–15 min (sodium lamp)
Power supply220 V AC, 50 Hz or 110 V AC, 60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Education and demonstration of optical activity
  • Sugar cane and syrup field checks
  • Occasional screening of chiral solutions
  • Low-volume research laboratories

Key features

  • Half-shadow polarizer gives a sensitive visual end point for trained operators.
  • Double vernier scale reads to 0.05° without electronics.
  • Sodium lamp or filtered source provides monochromatic 589 nm illumination.
  • Simple mechanical design tolerates handling in teaching environments.
  • Standard 100 mm and 200 mm tubes fit the sample compartment.
  • Low purchase and maintenance cost suits infrequent use.

Frequently asked questions about Manual Visual Polarimeter

Typical accuracy is about ±0.05° with a vernier scale, but real repeatability depends on operator experience and averaging several readings. It is adequate for teaching and rough concentration checks but not for pharmacopoeial release tests requiring 0.001° resolution.

Related models

All Polarimeters

Request a quotation for the Manual Visual Polarimeter

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote