Automatic Digital Polarimeter
自动数字旋光仪
- SKU POL-0001
- Polarimeters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement range | ±90° optical rotation |
|---|---|
| Readability | 0.01° |
| Accuracy | ±0.02° (0–30° range) |
| Wavelength | 589 nm (LED) |
| Tube length | 100 mm and 200 mm |
| Measurement time | ≤5 s |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <781>, Ph. Eur. 2.2.7, JP 2.49
What is the Automatic Digital Polarimeter?
An automatic digital polarimeter finds the optical null electronically and displays rotation, specific rotation or concentration without visual matching. It is the general-purpose choice for quality control laboratories needing repeatable readings at 0.01° resolution and fast throughput.
What is the Automatic Digital Polarimeter?
An automatic digital polarimeter finds the optical null electronically and displays rotation, specific rotation or concentration without visual matching. It is the general-purpose choice for quality control laboratories needing repeatable readings at 0.01° resolution and fast throughput.
Overview
The automatic digital polarimeter uses a modulated polarizer or rotating analyzer with a photodetector to locate the null point and report optical rotation in a few seconds. A sodium D line LED at 589 nm is typical, and a touchscreen calculates specific rotation, concentration and sugar degrees from entered parameters. Readability of 0.01° and accuracy of ±0.02° cover most food, chemical and routine pharmaceutical work. Models accept 100 mm and 200 mm tubes, and temperature is read by a probe rather than controlled. Methods can be stored, results printed or transferred by USB, and measurement cycles are repeatable across operators, removing the subjectivity of visual instruments. This variant is lower in cost than Peltier-controlled systems but does not satisfy the strictest pharmacopoeial temperature requirements unless the sample is conditioned externally.
How does it work?
A polarimeter passes monochromatic light, usually from a sodium D line source at 589.3 nm or an LED with a filter, through a polarizer, a sample tube and an analyzer. An optically active sample rotates the plane of polarization by an angle proportional to path length, concentration and specific rotation, following Biot's law. Manual instruments rely on the operator matching a split field visually, while automatic instruments use a Faraday modulator or a rotating analyzer with a photodetector to find the null position. Temperature strongly affects rotation, so many models include a thermostatted sample chamber, often Peltier controlled to 20.0 °C or 25.0 °C. Results are reported as optical rotation in degrees, specific rotation, concentration, or sugar scale such as °Z or ISS. Some models add multiple wavelengths to allow measurement of optical rotatory dispersion.
What are the key features?
- Electronic null detection removes operator subjectivity from visual matching.
- 589 nm LED source avoids warm-up delays and lamp replacement.
- Touchscreen calculates specific rotation, concentration and sugar degree automatically.
- Temperature probe records sample temperature with each measurement.
- Stored methods speed routine tests and reduce input errors.
- USB and printer output support simple record keeping.
What are the technical specifications?
A typical automatic digital polarimeter configuration offers measurement range of ±90° optical rotation, readability of 0.01°, accuracy of ±0.02° (0–30° range), wavelength of 589 nm (LED), tube length of 100 mm and 200 mm and measurement time of ≤5 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automatic Digital Polarimeter is used in food and sugar quality control, routine chemical QC, flavor and fragrance testing and teaching and training laboratories. Across the wider Polarimeters class, laboratories also deploy it for pharmaceutical QC of chiral drug substances, sugar and syrup concentration testing and essential oil and flavor purity checks.
Which standards and certifications apply?
Relevant standards and methods include USP <781>, Ph. Eur. 2.2.7, JP 2.49, ICUMSA GS2/3-1, OIML R 14 and GB/T 613. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the polarimeter on a vibration-free bench away from direct sunlight and strong electromagnetic fields. Allow the light source to warm up for 15–30 minutes before use. Verify performance with certified quartz control plates or a sucrose solution at defined concentration, and record results in the calibration log. Keep sample tubes clean and free of air bubbles, as bubbles cause unstable readings. Replace tube windows and seals when scratched or leaking. Confirm temperature at the sample, not only at the chamber setpoint. For regulated work, ensure 21 CFR Part 11 compatible software, scheduled calibration against traceable standards and documented installation and operational qualification.
How do I select the right Automatic Digital Polarimeter?
Select the automatic digital polarimeter for routine quality control where 0.01° readability is sufficient and strict temperature control is not mandated. Compared with the Peltier model it costs less, and compared with the manual type it removes operator variation. In an RFQ, specify measurement range, readability, wavelength, tube lengths, output interfaces and whether certified quartz control plates should be supplied.
How does it compare with other Polarimeters variants?
Choose a polarimeter by the required accuracy, measurement wavelength, temperature control and regulatory context. Pharmacopoeial testing of drug substances needs an automatic instrument with readability of 0.001° or better, Peltier control within ±0.1 °C and audit-trail software. Sugar and food quality control can use a saccharimeter with an ICUMSA-traceable scale and tolerates ±0.01° accuracy. Manual instruments suit teaching and low-volume checks where budget dominates. Samples that are dark or turbid need a polarimeter with high light throughput and short tubes. Chiral detection in chromatography requires a flow-through cell with a small volume. Also specify tube lengths, including 100 mm and 200 mm, sample volume and whether multiple wavelengths such as 436 nm or 546 nm are required for research work.
Full specifications
| Measurement range | ±90° optical rotation |
|---|---|
| Readability | 0.01° |
| Accuracy | ±0.02° (0–30° range) |
| Wavelength | 589 nm (LED) |
| Tube length | 100 mm and 200 mm |
| Measurement time | ≤5 s |
| Temperature reading | 0–50 °C probe |
| Display | 7-inch touchscreen |
| Outputs | USB, RS-232, printer |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Food and sugar quality control
- Routine chemical QC
- Flavor and fragrance testing
- Teaching and training laboratories
Key features
- Electronic null detection removes operator subjectivity from visual matching.
- 589 nm LED source avoids warm-up delays and lamp replacement.
- Touchscreen calculates specific rotation, concentration and sugar degree automatically.
- Temperature probe records sample temperature with each measurement.
- Stored methods speed routine tests and reduce input errors.
- USB and printer output support simple record keeping.
Frequently asked questions about Automatic Digital Polarimeter
Typical automatic digital polarimeters offer 0.01° readability and ±0.02° accuracy, which is adequate for food, sugar and routine chemical testing. Pharmacopoeial work on drug substances may require 0.001° readability, available on higher-specification Peltier-controlled instruments.
Yes, within limits. Light throughput decreases with color and turbidity, so use a shorter tube such as 100 mm or dilute the sample. Samples that absorb strongly at 589 nm may need a filter, a high-intensity source or a different wavelength.
Yes. After the user enters tube length and sample concentration, the instrument computes specific rotation from the measured rotation. It can also convert readings to sugar degrees or concentration using stored formulas or a user-defined calibration factor.
A polarimeter measures the angle by which an optically active sample rotates plane-polarized light. From the rotation, path length and temperature, the analyst calculates specific rotation, concentration or purity. It is used for sugars, amino acids, essential oils and chiral pharmaceutical ingredients.
Optical rotation changes with temperature, often by several tenths of a percent per degree Celsius for sugars and more for some drugs. Pharmacopoeial methods typically specify 20 °C or 25 °C, so Peltier-controlled sample chambers are used to hold the sample within ±0.1 °C.
Most polarimeters use 589 nm, the sodium D line, because pharmacopoeias and sugar standards refer to it. Modern instruments achieve this with filtered LEDs or sodium lamps. Additional wavelengths such as 365, 436, 546 and 633 nm support research and optical rotatory dispersion studies.
Related models