

Peltier-Controlled Automatic Polarimeter
帕尔贴控温自动旋光仪
- SKU POL-0002
- Polarimeters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement range | ±89.999° optical rotation |
|---|---|
| Readability | 0.001° |
| Accuracy | ±0.003° (0–10° range) |
| Temperature control range | 15–40 °C |
| Temperature stability | ±0.1 °C |
| Wavelength | 589 nm (optional 365/436/546 nm) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <781>, Ph. Eur. 2.2.7, JP 2.49
What is the Peltier-Controlled Automatic Polarimeter?
A Peltier-controlled automatic polarimeter combines high-resolution optical rotation measurement with a thermostatted sample chamber held within ±0.1 °C. It is the suitable choice for pharmacopoeial testing of chiral drug substances, where method temperature and 0.001° readability are specified.
What is the Peltier-Controlled Automatic Polarimeter?
A Peltier-controlled automatic polarimeter combines high-resolution optical rotation measurement with a thermostatted sample chamber held within ±0.1 °C. It is the suitable choice for pharmacopoeial testing of chiral drug substances, where method temperature and 0.001° readability are specified.
Overview
This variant integrates a Peltier heating and cooling element directly around the sample tube, allowing the operator to set 15–40 °C and reach stability within minutes. Readability of 0.001° and accuracy of ±0.003° in the low range meet the requirements of USP <781> and Ph. Eur. 2.2.7 for specific rotation of drug substances. A Faraday modulator measures rotation with high signal-to-noise, and software features include multi-user access, electronic records, audit trails and electronic signatures compatible with 21 CFR Part 11. A temperature sensor in contact with the sample tube confirms actual conditions. Some models offer a second wavelength such as 365 nm or 546 nm. Because of the added optics and thermal control, this is the most capable of the benchtop polarimeters used in quality control, with correspondingly higher price and calibration demands.
How does it work?
A polarimeter passes monochromatic light, usually from a sodium D line source at 589.3 nm or an LED with a filter, through a polarizer, a sample tube and an analyzer. An optically active sample rotates the plane of polarization by an angle proportional to path length, concentration and specific rotation, following Biot's law. Manual instruments rely on the operator matching a split field visually, while automatic instruments use a Faraday modulator or a rotating analyzer with a photodetector to find the null position. Temperature strongly affects rotation, so many models include a thermostatted sample chamber, often Peltier controlled to 20.0 °C or 25.0 °C. Results are reported as optical rotation in degrees, specific rotation, concentration, or sugar scale such as °Z or ISS. Some models add multiple wavelengths to allow measurement of optical rotatory dispersion.
What are the key features?
- Integrated Peltier chamber holds sample temperature within ±0.1 °C from 15–40 °C.
- Faraday modulation delivers 0.001° readability with low noise.
- Audit trail, user levels and e-signatures support 21 CFR Part 11 workflows.
- Sensor in contact with the tube verifies actual sample temperature.
- Automatic temperature-sweep option records rotation versus temperature.
- Optional second wavelength supports comparison with literature values.
What are the technical specifications?
A typical peltier-controlled automatic polarimeter configuration offers measurement range of ±89.999° optical rotation, readability of 0.001°, accuracy of ±0.003° (0–10° range), temperature control range of 15–40 °C, temperature stability of ±0.1 °C and wavelength of 589 nm (optional 365/436/546 nm). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Peltier-Controlled Automatic Polarimeter is used in pharmacopoeial specific rotation testing, chiral API release testing, reference standard characterization and stability studies of optically active drugs. Across the wider Polarimeters class, laboratories also deploy it for pharmaceutical QC of chiral drug substances, sugar and syrup concentration testing and essential oil and flavor purity checks.
Which standards and certifications apply?
Relevant standards and methods include USP <781>, Ph. Eur. 2.2.7, JP 2.49, ICUMSA GS2/3-1, OIML R 14 and GB/T 613. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the polarimeter on a vibration-free bench away from direct sunlight and strong electromagnetic fields. Allow the light source to warm up for 15–30 minutes before use. Verify performance with certified quartz control plates or a sucrose solution at defined concentration, and record results in the calibration log. Keep sample tubes clean and free of air bubbles, as bubbles cause unstable readings. Replace tube windows and seals when scratched or leaking. Confirm temperature at the sample, not only at the chamber setpoint. For regulated work, ensure 21 CFR Part 11 compatible software, scheduled calibration against traceable standards and documented installation and operational qualification.
How do I select the right Peltier-Controlled Automatic Polarimeter?
Select the Peltier-controlled model when a pharmacopoeial monograph or internal method specifies a temperature, when 0.001° readability is required, or when regulatory data integrity is audited. It is unnecessary for routine sugar testing. In an RFQ, specify temperature range and stability, readability, wavelengths, micro-cell availability, software compliance and qualification documentation.
How does it compare with other Polarimeters variants?
Choose a polarimeter by the required accuracy, measurement wavelength, temperature control and regulatory context. Pharmacopoeial testing of drug substances needs an automatic instrument with readability of 0.001° or better, Peltier control within ±0.1 °C and audit-trail software. Sugar and food quality control can use a saccharimeter with an ICUMSA-traceable scale and tolerates ±0.01° accuracy. Manual instruments suit teaching and low-volume checks where budget dominates. Samples that are dark or turbid need a polarimeter with high light throughput and short tubes. Chiral detection in chromatography requires a flow-through cell with a small volume. Also specify tube lengths, including 100 mm and 200 mm, sample volume and whether multiple wavelengths such as 436 nm or 546 nm are required for research work.
Full specifications
| Measurement range | ±89.999° optical rotation |
|---|---|
| Readability | 0.001° |
| Accuracy | ±0.003° (0–10° range) |
| Temperature control range | 15–40 °C |
| Temperature stability | ±0.1 °C |
| Wavelength | 589 nm (optional 365/436/546 nm) |
| Minimum sample volume | ≥1 mL with 100 mm micro cell |
| Tube length | 10, 50, 100, 200 mm |
| Software compliance | 21 CFR Part 11 compatible |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Pharmacopoeial specific rotation testing
- Chiral API release testing
- Reference standard characterization
- Stability studies of optically active drugs
Key features
- Integrated Peltier chamber holds sample temperature within ±0.1 °C from 15–40 °C.
- Faraday modulation delivers 0.001° readability with low noise.
- Audit trail, user levels and e-signatures support 21 CFR Part 11 workflows.
- Sensor in contact with the tube verifies actual sample temperature.
- Automatic temperature-sweep option records rotation versus temperature.
- Optional second wavelength supports comparison with literature values.
Frequently asked questions about Peltier-Controlled Automatic Polarimeter
A properly qualified Peltier polarimeter with 0.001° readability, traceable calibration and sample temperature control within the specified tolerance can be used for USP <781> tests. Suitability must be demonstrated by the laboratory with certified quartz plates or reference solutions before use.
With a Peltier chamber, a 100 mm tube typically reaches the set point, such as 20.0 °C, within 2–5 minutes from near ambient. Larger temperature changes or viscous samples take longer, so the instrument monitors stability before recording a reading.
Yes. Micro cells with 10 mm or 50 mm path and volumes of about 0.5–2 mL allow measurement of scarce reference standards or research compounds. Specific rotation is then calculated with the shorter path length entered in the method.
A polarimeter measures the angle by which an optically active sample rotates plane-polarized light. From the rotation, path length and temperature, the analyst calculates specific rotation, concentration or purity. It is used for sugars, amino acids, essential oils and chiral pharmaceutical ingredients.
Optical rotation changes with temperature, often by several tenths of a percent per degree Celsius for sugars and more for some drugs. Pharmacopoeial methods typically specify 20 °C or 25 °C, so Peltier-controlled sample chambers are used to hold the sample within ±0.1 °C.
Most polarimeters use 589 nm, the sodium D line, because pharmacopoeias and sugar standards refer to it. Modern instruments achieve this with filtered LEDs or sodium lamps. Additional wavelengths such as 365, 436, 546 and 633 nm support research and optical rotatory dispersion studies.





