Benchtop Ratio Nephelometric Turbidity Meter

台式比率散射浊度计

  • SKU TUM-0001
  • Turbidity Meters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measuring range0–4000 NTU (auto-ranging)
Resolution0.001 NTU (0–10 NTU)
Accuracy±2% of reading + 0.01 NTU
Stray light≤0.01 NTU
Light sourceTungsten lamp or LED, 400–600 nm / 860 nm
Detection geometry90° scatter, forward scatter, transmitted
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7027-1, USEPA Method 180.1, GB/T 13200

What is the Benchtop Ratio Nephelometric Turbidity Meter?

A benchtop ratio turbidity meter uses a white-light tungsten or LED source with 90°, forward-scatter and transmitted detectors to compensate for color and lamp drift. It is the standard laboratory choice for accurate readings from 0.01 to 4000 NTU on clear to moderately turbid samples.

What is the Benchtop Ratio Nephelometric Turbidity Meter?

A benchtop ratio turbidity meter uses a white-light tungsten or LED source with 90°, forward-scatter and transmitted detectors to compensate for color and lamp drift. It is the standard laboratory choice for accurate readings from 0.01 to 4000 NTU on clear to moderately turbid samples.

Overview

The benchtop ratio turbidimeter measures scattered light at 90° and divides it by a combination of forward-scatter and transmitted signals, which stabilizes readings against sample color, lamp aging and mild contamination of the vial. Typical specifications include 0–4000 NTU range with 0.001 NTU resolution below 10 NTU, accuracy of ±2% of reading plus 0.01 NTU, and stray light below 0.01 NTU. Auto-ranging, multi-point calibration with 0.1, 20, 200 and 1000 NTU standards and signal averaging are standard. A large touchscreen presents readings in NTU, FNU or EBC where configured, and data can be exported by USB or LIMS. The design meets the optical geometry of USEPA Method 180.1 with a tungsten lamp, and LED-based versions may additionally support ISO 7027 operation. It is suited to laboratories needing one instrument for diverse liquid samples.

How does it work?

A turbidity meter directs a beam of light through a sample and measures the portion scattered by suspended particles. In nephelometry the detector sits at 90° to the incident beam, and the signal is proportional to particle concentration within the linear range. Tungsten lamps at 400–600 nm are described in USEPA Method 180.1 and reported in NTU, while infrared LEDs at 860 nm are specified in ISO 7027 and reported in FNU. Ratio designs combine the 90° signal with transmitted and forward-scatter detectors to compensate for color and lamp drift. Calibration uses formazin or stabilized polymer standards such as 0.1, 20, 100 and 800 NTU. Some beverage instruments add a 25° detector to measure beer haze in EBC units, because larger particles scatter predominantly forward.

What are the key features?

  • Ratio optics compensate for sample color, lamp drift and minor vial contamination.
  • Auto-ranging covers 0–4000 NTU with 0.001 NTU resolution at low levels.
  • Multi-point calibration with stored standards and calibration history records.
  • Signal averaging and rate mode help stabilize particulate-laden samples.
  • USB and LIMS export with user login for traceable records.
  • Selectable NTU, FNU and EBC reporting units.

What are the technical specifications?

A typical benchtop ratio nephelometric turbidity meter configuration offers measuring range of 0–4000 NTU (auto-ranging), resolution of 0.001 NTU (0–10 NTU), accuracy of ±2% of reading + 0.01 NTU, stray light of ≤0.01 NTU, light source of Tungsten lamp or LED, 400–600 nm / 860 nm and detection geometry of 90° scatter, forward scatter, transmitted. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Benchtop Ratio Nephelometric Turbidity Meter is used in pharmaceutical water clarity, drinking water laboratory testing, chemical solution clarity and filtration efficiency evaluation. Across the wider Turbidity Meters class, laboratories also deploy it for filtered beverage and beer haze testing, pharmaceutical water clarity control and drinking water and wastewater monitoring.

Which standards and certifications apply?

Relevant standards and methods include ISO 7027-1, USEPA Method 180.1, GB/T 13200, Standard Methods 2130 B, ASBC Beer-9 and EBC Method 9.29. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Use clean, scratch-free and indexed sample vials, and wipe them with lint-free cloth and a thin film of silicone oil to hide minor imperfections. Degas samples and avoid bubbles, which produce false high readings. Calibrate with fresh formazin or certified stabilized standards, following the manufacturer's sequence, and verify with a secondary gel standard daily. Keep the optical chamber free of condensation by allowing cold samples to reach room temperature. Replace tungsten lamps according to hours of operation. Document calibration and verification records for GLP or ISO 17025 laboratories, and dispose of formazin according to local regulations because it contains hydrazine sulfate.

How do I select the right Benchtop Ratio Nephelometric Turbidity Meter?

Select the benchtop ratio turbidity meter as the general-purpose laboratory instrument for accurate readings over a wide range. Compared with portable models it offers better stray-light performance, and compared with process analyzers it handles discrete samples. In an RFQ, specify range, resolution, light source standard, unit selection, calibration standards and vial type.

How does it compare with other Turbidity Meters variants?

Choose a turbidity meter by measuring range, regulatory method, sample type and portability. Low-level clarity work below 1 NTU, such as filtered pharmaceutical water, requires a ratio benchtop instrument with stray light below 0.01 NTU and a resolution of 0.001 NTU. Wide-range industrial samples up to 4000 NTU suit a robust ratio design. Choose a white-light instrument for USEPA reporting and an infrared instrument for ISO 7027 compliance and colored samples. Beverage laboratories need EBC or ASBC units and a 25° channel. Field work favors portable, battery-powered models with IP67 housing. Online measurement needs a bubble trap and automatic cleaning. Specify vial or flow-cell format, calibration standards supplied and data output requirements.

Full specifications

Full specifications
Measuring range0–4000 NTU (auto-ranging)
Resolution0.001 NTU (0–10 NTU)
Accuracy±2% of reading + 0.01 NTU
Stray light≤0.01 NTU
Light sourceTungsten lamp or LED, 400–600 nm / 860 nm
Detection geometry90° scatter, forward scatter, transmitted
CalibrationMulti-point, formazin or stabilized standards
Sample volume10–30 mL vial
Data outputUSB, RS-232, LIMS
Power supply100–240 V AC, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Pharmaceutical water clarity
  • Drinking water laboratory testing
  • Chemical solution clarity
  • Filtration efficiency evaluation

Key features

  • Ratio optics compensate for sample color, lamp drift and minor vial contamination.
  • Auto-ranging covers 0–4000 NTU with 0.001 NTU resolution at low levels.
  • Multi-point calibration with stored standards and calibration history records.
  • Signal averaging and rate mode help stabilize particulate-laden samples.
  • USB and LIMS export with user login for traceable records.
  • Selectable NTU, FNU and EBC reporting units.

Frequently asked questions about Benchtop Ratio Nephelometric Turbidity Meter

Ratio designs divide the 90° scatter signal by other detector signals, which cancels many errors from sample color, lamp aging and vial marks. The result is better stability and accuracy for colored or slightly contaminated samples than with a single 90° detector.

Related models

All Turbidity Meters

Request a quotation for the Benchtop Ratio Nephelometric Turbidity Meter

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote