Skip to main content
Lab Manufacturers China
Laboratory TOC Analyzer — product photo

Laboratory TOC Analyzer

实验室总有机碳(TOC)分析仪

  • SKU ANA-0003
  • Analytical Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measuring range (TOC)4 µg/L–30000 mg/L
Detection limit≤4 µg/L (high-sensitivity configuration)
Oxidation method680 °C catalytic combustion or UV-persulfate
DetectorNon-dispersive infrared (NDIR)
RepeatabilityRSD ≤2%
Analysis time3–5 min per sample
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <921>, USP <643>, Ph. Eur. 2.5.12

What is the Laboratory TOC Analyzer?

A laboratory TOC analyzer measures total organic carbon by oxidizing carbon compounds to CO2 and detecting it by non-dispersive infrared. It quantifies organic contamination in pharmaceutical water, drinking water, wastewater and cleaning validation samples from 1 ppb to several thousand mg/L.

What is the Laboratory TOC Analyzer?

A laboratory TOC analyzer measures total organic carbon by oxidizing carbon compounds to CO2 and detecting it by non-dispersive infrared. It quantifies organic contamination in pharmaceutical water, drinking water, wastewater and cleaning validation samples from 1 ppb to several thousand mg/L.

Overview

The TOC analyzer oxidizes organic carbon by high-temperature catalytic combustion at 680–900 °C or by UV-persulfate wet oxidation. The CO2 produced is carried to a non-dispersive infrared detector and quantified. Inorganic carbon is removed by acidification and sparging before measurement, or measured separately to give TOC by difference. High-temperature combustion handles particulates and high-salt samples, while UV-persulfate suits low-level ultrapure water from 0.05 mg/L. Autosamplers with 40–100 positions enable unattended operation, and system suitability tests using sucrose and benzoquinone support USP <643> and Ph. Eur. 2.2.44 compliance. Regular replacement of catalyst, halogen scrubber and sparge gas ensures stable blank values. Results are reported as TOC, NPOC, TC and IC, and software tracks calibration, blank and suitability tests for audit.

How does it work?

Analytical analyzers combine a sample handling stage, a selective sensor or measurement principle and a data system that converts the raw signal to a reported value. Examples include thermogravimetric drying with a balance for moisture, coulometric or volumetric titration for water, catalytic oxidation with infrared detection for organic carbon, light scattering for particle size and ion-selective electrodes for electrochemical parameters. Each design is optimized for one analyte class and sample matrix, which improves speed, repeatability and ease of use over general-purpose instruments. Calibration against certified reference materials links the output to SI units. Automation such as autosamplers, dosing units and validated software methods reduces operator variation. Results are stored with audit trails so that measurements can be traced to instrument, method and operator during regulatory inspection.

What are the key features?

  • High-temperature catalytic combustion handles particulates and high-salt samples.
  • Non-dispersive infrared detector covers 1 ppb to 30000 mg/L with dilution.
  • Autosampler with 40 to 100 positions allows unattended runs.
  • NPOC, TOC, TC and IC modes reported from a single sample.
  • System suitability tests support USP <643> and Ph. Eur. 2.2.44.
  • Halogen scrubber and catalyst life indicators simplify maintenance planning.

What are the technical specifications?

A typical laboratory toc analyzer configuration offers measuring range (TOC) of 4 µg/L–30000 mg/L, detection limit of ≤4 µg/L (high-sensitivity configuration), oxidation method of 680 °C catalytic combustion or UV-persulfate, detector of Non-dispersive infrared (NDIR), repeatability of RSD ≤2% and analysis time of 3–5 min per sample. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Laboratory TOC Analyzer is used in pharmaceutical purified water testing, cleaning validation swab and rinse analysis, drinking water and wastewater monitoring, soil extract and environmental samples and semiconductor ultrapure water. Across the wider Analytical Analyzers class, laboratories also deploy it for pharmaceutical and API quality control, food and beverage composition testing and chemical and polymer characterization.

Which standards and certifications apply?

Relevant standards and methods include USP <921>, USP <643>, Ph. Eur. 2.5.12, ISO 760, ISO 13320, ASTM E203, ASTM D7573 and GB/T 6283. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install analyzers on stable benches with controlled temperature and humidity, away from drafts and vibration. Follow manufacturer requirements for gases, reagents, waste handling and ventilation. Calibrate and verify routinely using certified reference materials relevant to the matrix, and schedule preventive maintenance for consumables such as electrodes, lamps, catalysts and dispersion units. Validate methods for accuracy, repeatability and linearity before release testing, and record them under a quality system such as ISO 17025 or GMP. Use software with user levels, audit trail and electronic signatures where regulated. Provide training for sample preparation, because sampling error is usually the largest contributor to measurement uncertainty.

How do I select the right Laboratory TOC Analyzer?

Select a laboratory TOC analyzer when discrete samples with variable matrices, including particulates or salts, must be measured, such as cleaning validation and wastewater. For purified water release only, an online or UV-persulfate unit may suffice. In an RFQ, specify range, oxidation method, autosampler size, gas supply and compliance documentation.

How does it compare with other Analytical Analyzers variants?

Start from the measurand and the sample matrix. Determine the required concentration range, accuracy, sample throughput and regulatory method, then select the analyzer type that natively meets them. For water in solids and liquids at ppm levels, a Karl Fischer titrator is the reference, while a halogen moisture analyzer suits fast loss-on-drying checks above 0.1%. TOC analyzers should be matched to the expected range and the presence of particulates or salts. Laser diffraction covers 0.01 to 3500 µm for dry or wet dispersions. Benchtop multiparameter analyzers suit labs measuring pH, conductivity and dissolved oxygen together. Also consider sample preparation needs, consumables, software compliance, automation level and local service support.

Full specifications

Full specifications
Measuring range (TOC)4 µg/L–30000 mg/L
Detection limit≤4 µg/L (high-sensitivity configuration)
Oxidation method680 °C catalytic combustion or UV-persulfate
DetectorNon-dispersive infrared (NDIR)
RepeatabilityRSD ≤2%
Analysis time3–5 min per sample
Autosampler capacity40–100 vials
Carrier gasHigh-purity oxygen or air, 150–200 mL/min
Measured parametersTOC, NPOC, TC, IC
InterfacesUSB, Ethernet, LIMS export

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Pharmaceutical purified water testing
  • Cleaning validation swab and rinse analysis
  • Drinking water and wastewater monitoring
  • Soil extract and environmental samples
  • Semiconductor ultrapure water

Key features

  • High-temperature catalytic combustion handles particulates and high-salt samples.
  • Non-dispersive infrared detector covers 1 ppb to 30000 mg/L with dilution.
  • Autosampler with 40 to 100 positions allows unattended runs.
  • NPOC, TOC, TC and IC modes reported from a single sample.
  • System suitability tests support USP <643> and Ph. Eur. 2.2.44.
  • Halogen scrubber and catalyst life indicators simplify maintenance planning.

Frequently asked questions about Laboratory TOC Analyzer

TOC is total organic carbon, while NPOC is non-purgeable organic carbon measured after acidifying and sparging away inorganic carbon. In most waters, NPOC equals TOC, but volatile organics can be lost in NPOC mode, so the method should be chosen for the sample.

Request a quotation for the Laboratory TOC Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote