Benchtop Multiparameter Electrochemical Analyzer

台式多参数电化学分析仪

  • SKU ANA-0005
  • Analytical Analyzers
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
pH range−2.000 to 20.000
pH accuracy±0.002 (electronics)
Conductivity range0.000 µS/cm–1000 mS/cm
Dissolved oxygen range0.00–50.00 mg/L
ORP range±2000 mV
Temperature range−5 to 105 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <921>, USP <643>, Ph. Eur. 2.5.12

What is the Benchtop Multiparameter Electrochemical Analyzer?

A benchtop multiparameter electrochemical analyzer measures pH, conductivity, dissolved oxygen, ORP and ion concentration with interchangeable electrodes. It is chosen by laboratories that need several parameters from one instrument with documented calibration and data storage.

What is the Benchtop Multiparameter Electrochemical Analyzer?

A benchtop multiparameter electrochemical analyzer measures pH, conductivity, dissolved oxygen, ORP and ion concentration with interchangeable electrodes. It is chosen by laboratories that need several parameters from one instrument with documented calibration and data storage.

Overview

The benchtop multiparameter analyzer provides two to four channels that accept pH, conductivity, dissolved oxygen, ORP and ion-selective electrodes. pH measurement covers −2.000 to 20.000 with resolution of 0.001 and accuracy of ±0.002 pH, conductivity 0.000 µS/cm to 1000 mS/cm with automatic temperature compensation, and optical or polarographic dissolved oxygen up to 50 mg/L. Automatic buffer recognition with up to five-point calibration and slope/offset reports support GLP records. A color touchscreen with method library and a stirrer-holder stand streamline daily work, and data are exported to USB, printer or LIMS. Electronic records with audit trail and user management support 21 CFR Part 11 needs. Electrodes are consumables, require storage in proper solutions and regular cleaning, and the system suits water, food, pharmaceutical and general chemical laboratories.

How does it work?

Analytical analyzers combine a sample handling stage, a selective sensor or measurement principle and a data system that converts the raw signal to a reported value. Examples include thermogravimetric drying with a balance for moisture, coulometric or volumetric titration for water, catalytic oxidation with infrared detection for organic carbon, light scattering for particle size and ion-selective electrodes for electrochemical parameters. Each design is optimized for one analyte class and sample matrix, which improves speed, repeatability and ease of use over general-purpose instruments. Calibration against certified reference materials links the output to SI units. Automation such as autosamplers, dosing units and validated software methods reduces operator variation. Results are stored with audit trails so that measurements can be traced to instrument, method and operator during regulatory inspection.

What are the key features?

  • Two to four channels accept pH, conductivity, dissolved oxygen, ORP and ISE sensors.
  • Automatic buffer recognition with up to five-point calibration and slope reporting.
  • Automatic temperature compensation for pH, conductivity and dissolved oxygen.
  • Method library and color touchscreen reduce operator setup time.
  • Audit trail, user levels and e-signature support regulated laboratories.
  • USB, printer and LIMS export with sensor identification and calibration history.

What are the technical specifications?

A typical benchtop multiparameter electrochemical analyzer configuration offers pH range of −2.000 to 20.000, pH accuracy of ±0.002 (electronics), conductivity range of 0.000 µS/cm–1000 mS/cm, dissolved oxygen range of 0.00–50.00 mg/L, ORP range of ±2000 mV and temperature range of −5 to 105 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Benchtop Multiparameter Electrochemical Analyzer is used in water and wastewater laboratory analysis, pharmaceutical buffer and media testing, food and beverage acidity and salinity, environmental field-sample analysis and education and general chemistry. Across the wider Analytical Analyzers class, laboratories also deploy it for pharmaceutical and API quality control, food and beverage composition testing and chemical and polymer characterization.

Which standards and certifications apply?

Relevant standards and methods include USP <921>, USP <643>, Ph. Eur. 2.5.12, ISO 760, ISO 13320, ASTM E203, ASTM D7573 and GB/T 6283. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install analyzers on stable benches with controlled temperature and humidity, away from drafts and vibration. Follow manufacturer requirements for gases, reagents, waste handling and ventilation. Calibrate and verify routinely using certified reference materials relevant to the matrix, and schedule preventive maintenance for consumables such as electrodes, lamps, catalysts and dispersion units. Validate methods for accuracy, repeatability and linearity before release testing, and record them under a quality system such as ISO 17025 or GMP. Use software with user levels, audit trail and electronic signatures where regulated. Provide training for sample preparation, because sampling error is usually the largest contributor to measurement uncertainty.

How do I select the right Benchtop Multiparameter Electrochemical Analyzer?

Select the multiparameter analyzer when several electrochemical parameters are measured daily and traceable calibration records are needed. For a single parameter at high throughput, a dedicated meter or titrator may be simpler. In an RFQ, specify parameters, number of channels, electrodes included, accuracy class and compliance software.

How does it compare with other Analytical Analyzers variants?

Start from the measurand and the sample matrix. Determine the required concentration range, accuracy, sample throughput and regulatory method, then select the analyzer type that natively meets them. For water in solids and liquids at ppm levels, a Karl Fischer titrator is the reference, while a halogen moisture analyzer suits fast loss-on-drying checks above 0.1%. TOC analyzers should be matched to the expected range and the presence of particulates or salts. Laser diffraction covers 0.01 to 3500 µm for dry or wet dispersions. Benchtop multiparameter analyzers suit labs measuring pH, conductivity and dissolved oxygen together. Also consider sample preparation needs, consumables, software compliance, automation level and local service support.

Full specifications

Full specifications
pH range−2.000 to 20.000
pH accuracy±0.002 (electronics)
Conductivity range0.000 µS/cm–1000 mS/cm
Dissolved oxygen range0.00–50.00 mg/L
ORP range±2000 mV
Temperature range−5 to 105 °C
Channels2–4
Calibration pointsUp to 5 (pH)
Data storage≥5000 records
InterfacesUSB, RS-232, LIMS

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Water and wastewater laboratory analysis
  • Pharmaceutical buffer and media testing
  • Food and beverage acidity and salinity
  • Environmental field-sample analysis
  • Education and general chemistry

Key features

  • Two to four channels accept pH, conductivity, dissolved oxygen, ORP and ISE sensors.
  • Automatic buffer recognition with up to five-point calibration and slope reporting.
  • Automatic temperature compensation for pH, conductivity and dissolved oxygen.
  • Method library and color touchscreen reduce operator setup time.
  • Audit trail, user levels and e-signature support regulated laboratories.
  • USB, printer and LIMS export with sensor identification and calibration history.

Frequently asked questions about Benchtop Multiparameter Electrochemical Analyzer

Calibrate pH electrodes daily or before each measurement series using at least two fresh buffers that bracket the sample pH. Check the slope, which should be 95–105% of the theoretical value, and replace the electrode when slope or response time degrades.

Laboratory TOC Analyzer — product photo

Laboratory TOC Analyzer

实验室总有机碳(TOC)分析仪

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the Benchtop Multiparameter Electrochemical Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote