Laser Diffraction Particle Size Analyzer
激光衍射粒度分析仪
- SKU ANA-0004
- Analytical Analyzers
- CE (to be confirmed)
- Class 1 laser product IEC 60825-1 (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 0.01–3500 µm |
|---|---|
| Light sources | Red laser 632.8 nm, blue LED 470 nm |
| Detector angle range | 0.02–150° |
| Accuracy (D50) | ≤±1% with certified latex standard |
| Repeatability (D50) | ≤0.5% RSD |
| Dispersion modes | Wet, dry (compressed air) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <921>, USP <643>, Ph. Eur. 2.5.12
What is the Laser Diffraction Particle Size Analyzer?
A laser diffraction particle size analyzer measures particle size distributions from about 0.01 to 3500 µm by detecting the angular pattern of scattered laser light. It is used for powders, suspensions and emulsions in pharmaceutical, chemical, cement, food and battery materials laboratories.
What is the Laser Diffraction Particle Size Analyzer?
A laser diffraction particle size analyzer measures particle size distributions from about 0.01 to 3500 µm by detecting the angular pattern of scattered laser light. It is used for powders, suspensions and emulsions in pharmaceutical, chemical, cement, food and battery materials laboratories.
Overview
A laser diffraction analyzer passes a laser beam, typically 632.8 nm helium-neon or a red diode laser, through a dispersed sample, with a blue or violet source added for sub-micron sensitivity. Large particles scatter light at small angles, small particles at large angles, and an array of detectors up to 150° records the pattern. Mie or Fraunhofer theory converts the pattern to a volume-weighted size distribution, reporting D10, D50 and D90. Wet dispersion units use circulating liquid with ultrasonic assistance, while dry units disperse powders with compressed air at controlled pressure. Measurement takes under one minute and needs only small sample masses. Optical properties of sample and dispersant, including refractive index and absorption, must be known for accurate Mie results. The method conforms to ISO 13320 and USP <429>, and requires method development and dispersion validation.
How does it work?
Analytical analyzers combine a sample handling stage, a selective sensor or measurement principle and a data system that converts the raw signal to a reported value. Examples include thermogravimetric drying with a balance for moisture, coulometric or volumetric titration for water, catalytic oxidation with infrared detection for organic carbon, light scattering for particle size and ion-selective electrodes for electrochemical parameters. Each design is optimized for one analyte class and sample matrix, which improves speed, repeatability and ease of use over general-purpose instruments. Calibration against certified reference materials links the output to SI units. Automation such as autosamplers, dosing units and validated software methods reduces operator variation. Results are stored with audit trails so that measurements can be traced to instrument, method and operator during regulatory inspection.
What are the key features?
- Red and blue laser sources extend sensitivity to sub-micron particles.
- Wet and dry dispersion modules cover suspensions, emulsions and powders.
- Integrated ultrasonic probe breaks agglomerates during wet measurement.
- Reports D10, D50, D90, span and full volume distribution.
- Automatic alignment and background check before every measurement.
- SOP software with audit trail supports ISO 13320 and USP <429> work.
What are the technical specifications?
A typical laser diffraction particle size analyzer configuration offers measuring range of 0.01–3500 µm, light sources of Red laser 632.8 nm, blue LED 470 nm, detector angle range of 0.02–150°, accuracy (D50) of ≤±1% with certified latex standard, repeatability (D50) of ≤0.5% RSD and dispersion modes of Wet, dry (compressed air). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Laser Diffraction Particle Size Analyzer is used in pharmaceutical API micronization control, cement and mineral powders, emulsion and suspension stability, battery electrode materials and food powder and cocoa. Across the wider Analytical Analyzers class, laboratories also deploy it for pharmaceutical and API quality control, food and beverage composition testing and chemical and polymer characterization.
Which standards and certifications apply?
Relevant standards and methods include USP <921>, USP <643>, Ph. Eur. 2.5.12, ISO 760, ISO 13320, ASTM E203, ASTM D7573 and GB/T 6283. Certification candidates for this model are CE, Class 1 laser product IEC 60825-1 and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install analyzers on stable benches with controlled temperature and humidity, away from drafts and vibration. Follow manufacturer requirements for gases, reagents, waste handling and ventilation. Calibrate and verify routinely using certified reference materials relevant to the matrix, and schedule preventive maintenance for consumables such as electrodes, lamps, catalysts and dispersion units. Validate methods for accuracy, repeatability and linearity before release testing, and record them under a quality system such as ISO 17025 or GMP. Use software with user levels, audit trail and electronic signatures where regulated. Provide training for sample preparation, because sampling error is usually the largest contributor to measurement uncertainty.
How do I select the right Laser Diffraction Particle Size Analyzer?
Select laser diffraction for routine distributions from sub-micron to millimeter sizes across many material types. For sub-100 nm nanoparticles, dynamic light scattering is more appropriate, and for shape information, image analysis is needed. In an RFQ, specify size range, wet or dry modules, sample volume, theory models and SOP software features.
How does it compare with other Analytical Analyzers variants?
Start from the measurand and the sample matrix. Determine the required concentration range, accuracy, sample throughput and regulatory method, then select the analyzer type that natively meets them. For water in solids and liquids at ppm levels, a Karl Fischer titrator is the reference, while a halogen moisture analyzer suits fast loss-on-drying checks above 0.1%. TOC analyzers should be matched to the expected range and the presence of particulates or salts. Laser diffraction covers 0.01 to 3500 µm for dry or wet dispersions. Benchtop multiparameter analyzers suit labs measuring pH, conductivity and dissolved oxygen together. Also consider sample preparation needs, consumables, software compliance, automation level and local service support.
Full specifications
| Measuring range | 0.01–3500 µm |
|---|---|
| Light sources | Red laser 632.8 nm, blue LED 470 nm |
| Detector angle range | 0.02–150° |
| Accuracy (D50) | ≤±1% with certified latex standard |
| Repeatability (D50) | ≤0.5% RSD |
| Dispersion modes | Wet, dry (compressed air) |
| Wet cell volume | 100–500 mL |
| Dry dispersion pressure | 0.1–4 bar |
| Measurement time | ≤60 s |
| Theory models | Mie, Fraunhofer |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Pharmaceutical API micronization control
- Cement and mineral powders
- Emulsion and suspension stability
- Battery electrode materials
- Food powder and cocoa
Key features
- Red and blue laser sources extend sensitivity to sub-micron particles.
- Wet and dry dispersion modules cover suspensions, emulsions and powders.
- Integrated ultrasonic probe breaks agglomerates during wet measurement.
- Reports D10, D50, D90, span and full volume distribution.
- Automatic alignment and background check before every measurement.
- SOP software with audit trail supports ISO 13320 and USP <429> work.
Frequently asked questions about Laser Diffraction Particle Size Analyzer
ISO 13320 describes laser diffraction particle size analysis, and USP <429> covers light diffraction measurement of particle size for pharmaceutical use. Both require method validation, including dispersion, repeatability and accuracy checks with reference materials.
Mie theory models how particles of a given refractive index and absorption scatter light, so the accuracy of the distribution, especially below 10 µm, depends on correct optical inputs. Fraunhofer approximation does not need them but is reliable only for larger particles.
Use dry dispersion for free-flowing powders that are soluble in available liquids, sensitive to moisture, or where the dispersant would alter the particles. Wet dispersion is preferred for fine, cohesive powders and suspensions, and gives better de-agglomeration with ultrasound.
An analytical analyzer is a dedicated laboratory instrument that measures a specific property or group of properties, such as moisture, carbon content or particle size. It combines sample handling, a selective sensor and software to deliver quantified results quickly and repeatably.
Use Karl Fischer titration for specific water determination, including trace levels down to ppm, and when volatile solvents would bias weight loss. Use a halogen moisture analyzer for rapid loss-on-drying checks of robust materials where total volatiles, typically above 0.1%, are acceptable.
Most analyzers are verified daily or per batch with reference standards and formally calibrated at least annually. Frequency depends on the instrument, method criticality and quality system, and additional checks follow maintenance, consumable changes or out-of-trend results.
Related models