Saccharimeter
检糖计
- SKU PLR-0003
- Polarimeters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement scale | −130 to +130 °Z |
|---|---|
| Resolution | 0.01 °Z |
| Accuracy | ±0.03 °Z |
| Measuring wavelength | 589 nm |
| Light source | LED or sodium lamp |
| Temperature control | 20 °C ± 0.2 °C, Peltier |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <781>, Ph. Eur. 2.2.7, JP 2.49
What is the Saccharimeter?
A saccharimeter is a polarimeter calibrated in sugar degrees for measuring sucrose content. It reads directly on the international sugar scale and is the standard optical instrument in sugar mills, refineries and confectionery quality control.
What is the Saccharimeter?
A saccharimeter is a polarimeter calibrated in sugar degrees for measuring sucrose content. It reads directly on the international sugar scale and is the standard optical instrument in sugar mills, refineries and confectionery quality control.
Overview
A saccharimeter is a specialized polarimeter whose scale is graduated in sugar degrees, denoted °Z, corresponding to the international sugar scale defined by ICUMSA. It measures the optical rotation of a clarified sugar solution and converts it directly to apparent sucrose content, avoiding manual conversion from angular degrees. Automatic models use photoelectric detection and Peltier temperature control, and often display both sugar degrees and optical rotation. Sample preparation, including clarification and defecation, follows standard methods. The instrument is central to payment, process control and product specification in the sugar industry. Cleaning of tubes between samples prevents carryover between determinations.
How does it work?
A polarimeter passes light through a polarizer to produce plane-polarized light, then through a sample cell containing an optically active substance. The sample rotates the plane of polarization by an amount proportional to its concentration, path length and specific rotation. An analyser measures the rotation angle, historically by eye against a vernier scale and now by photoelectric detection with a servomotor or Faraday modulator. Monochromatic light is essential because optical rotation depends strongly on wavelength; the sodium D line at 589 nm is the conventional reference. Temperature control matters because specific rotation changes with temperature. The measured rotation is converted to concentration using the specific rotation and path length.
What are the key features?
- Scale graduated directly in sugar degrees
- Compliance with the international sugar scale
- Photoelectric detection with temperature control on automatic models
- Direct apparent sucrose readout
- Sample tubes matched to sugar-analysis methods
What are the technical specifications?
A typical saccharimeter configuration offers measurement scale of −130 to +130 °Z, resolution of 0.01 °Z, accuracy of ±0.03 °Z, measuring wavelength of 589 nm, light source of LED or sodium lamp and temperature control of 20 °C ± 0.2 °C, Peltier. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Saccharimeter is used in sugar mill and refinery process control, raw and refined sugar specification, confectionery and beverage quality control and molasses and syrup analysis. Across the wider Polarimeters class, laboratories also deploy it for pharmaceutical chiral purity and assay, sugar and sweetener analysis and essential oil and flavour authentication.
Which standards and certifications apply?
Relevant standards and methods include USP <781>, Ph. Eur. 2.2.7, JP 2.49, ICUMSA Method GS1/2/3 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Fit the polarimeter with the correct tube length and clean, bubble-free sample cells, and allow temperature equilibration before reading. Standardize the instrument with a certified quartz plate or a reference standard at the working wavelength and temperature, and record the result. Keep polarizers and windows clean to avoid stray light and scattering errors. Prepare samples at known concentration and temperature, and note the solvent because specific rotation depends on it. Service and recalibrate periodically, and verify the sodium lamp or light-emitting diode output, since wavelength drift biases results.
How do I select the right Saccharimeter?
Choose a saccharimeter for sugar analysis where results must be reported in sugar degrees according to ICUMSA methods. Confirm the scale range and resolution match the expected purity, and that temperature control maintains the specified condition. Specify the sample tubes and clarification procedures required by the method, and check data export for process records.
How does it compare with other Polarimeters variants?
Choose the polarimeter type according to the application. Sugar analysis uses a saccharimeter reading in sugar degrees, while chiral pharmaceutical testing uses an automatic polarimeter reading in angular degrees and often several wavelengths. Manual instruments suit teaching and occasional measurement where budget is limited. Where temperature-sensitive substances are tested, select a model with Peltier temperature control. Confirm the required resolution, accuracy and tube length, and whether sample tubes or flow cells are needed. For regulatory work, check that the wavelength, temperature and data records match pharmacopoeial requirements, and that the instrument supports audit trails and controlled user access.
Full specifications
| Measurement scale | −130 to +130 °Z |
|---|---|
| Resolution | 0.01 °Z |
| Accuracy | ±0.03 °Z |
| Measuring wavelength | 589 nm |
| Light source | LED or sodium lamp |
| Temperature control | 20 °C ± 0.2 °C, Peltier |
| Sample tubes | 100 mm and 200 mm |
| Display | LCD, sugar degrees and rotation |
| Data interface | USB, RS-232 |
| Power supply | 100–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Sugar mill and refinery process control
- Raw and refined sugar specification
- Confectionery and beverage quality control
- Molasses and syrup analysis
Key features
- Scale graduated directly in sugar degrees
- Compliance with the international sugar scale
- Photoelectric detection with temperature control on automatic models
- Direct apparent sucrose readout
- Sample tubes matched to sugar-analysis methods
Frequently asked questions about Saccharimeter
A sugar degree, written °Z, is the unit of the international sugar scale. It expresses the apparent sucrose content of a solution based on its optical rotation under defined conditions. Saccharimeters read directly in these units, which are accepted in sugar trade and specification.
Yes. Turbidity, colour and suspended solids scatter or absorb light and bias the reading, so sugar solutions are clarified and defecated according to the standard method before measurement. The reagents and procedure are specified in the applicable ICUMSA method and must be followed consistently.
The rotation of sugar solutions changes with temperature, and the international sugar scale is defined at 20 °C. Peltier-controlled saccharimeters hold this temperature so results are comparable and payments based on sugar content are fair.
A polarimeter measures the angle by which an optically active sample rotates the plane of polarized light. From the measured rotation, the path length and the specific rotation of the substance, the concentration can be calculated. It also detects the presence of chiral compounds.
Optical rotation depends strongly on wavelength, a phenomenon called optical rotatory dispersion. Broad-band light would give an averaged and unstable reading, so a single wavelength is used, most commonly the sodium D line at 589 nm, as specified in pharmacopoeial methods.
A polarimeter reports optical rotation in angular degrees, while a saccharimeter is calibrated in sugar degrees, denoted °Z, using the international sugar scale. Saccharimeters are used mainly in sugar and food analysis, where results are expressed directly as sucrose content.
Related models