Multi-Wavelength Polarimeter
多波长旋光仪
- SKU PLR-0004
- Polarimeters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement scale | ±90° optical rotation |
|---|---|
| Wavelengths | 365, 405, 436, 546, 589, 633 nm |
| Resolution | 0.001° |
| Accuracy | ±0.01° |
| Light source | LED or xenon lamp with filters |
| Temperature control | 20 °C ± 0.2 °C, Peltier |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <781>, Ph. Eur. 2.2.7, JP 2.49
What is the Multi-Wavelength Polarimeter?
A multi-wavelength polarimeter measures optical rotation at several wavelengths, allowing optical rotatory dispersion and improved selectivity. It is used for research and for samples where a single wavelength gives insufficient selectivity or information.
What is the Multi-Wavelength Polarimeter?
A multi-wavelength polarimeter measures optical rotation at several wavelengths, allowing optical rotatory dispersion and improved selectivity. It is used for research and for samples where a single wavelength gives insufficient selectivity or information.
Overview
A multi-wavelength polarimeter is fitted with several interchangeable filters or light-emitting diodes, commonly covering 365, 405, 436, 546, 589 and 633 nm. Measuring at more than one wavelength allows optical rotatory dispersion to be studied, improves identification of closely related substances and can reduce the effect of absorbing impurities at a single wavelength. The optical and electronic design is similar to an automatic polarimeter, with photoelectric detection and temperature control. Software manages wavelength selection, multiple measurements and comparison of rotation across wavelengths. The instrument is used in pharmaceutical development, natural product research and chiral chemistry.
How does it work?
A polarimeter passes light through a polarizer to produce plane-polarized light, then through a sample cell containing an optically active substance. The sample rotates the plane of polarization by an amount proportional to its concentration, path length and specific rotation. An analyser measures the rotation angle, historically by eye against a vernier scale and now by photoelectric detection with a servomotor or Faraday modulator. Monochromatic light is essential because optical rotation depends strongly on wavelength; the sodium D line at 589 nm is the conventional reference. Temperature control matters because specific rotation changes with temperature. The measured rotation is converted to concentration using the specific rotation and path length.
What are the key features?
- Multiple selectable measuring wavelengths
- Optical rotatory dispersion measurement
- Photoelectric detection with temperature control
- Software for multi-wavelength comparison
- Improved selectivity for closely related substances
What are the technical specifications?
A typical multi-wavelength polarimeter configuration offers measurement scale of ±90° optical rotation, wavelengths of 365, 405, 436, 546, 589, 633 nm, resolution of 0.001°, accuracy of ±0.01°, light source of LED or xenon lamp with filters and temperature control of 20 °C ± 0.2 °C, Peltier. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Multi-Wavelength Polarimeter is used in pharmaceutical chiral research and development, natural product and flavour analysis, optical rotatory dispersion studies and purity assessment of optically active compounds. Across the wider Polarimeters class, laboratories also deploy it for pharmaceutical chiral purity and assay, sugar and sweetener analysis and essential oil and flavour authentication.
Which standards and certifications apply?
Relevant standards and methods include USP <781>, Ph. Eur. 2.2.7, JP 2.49, ICUMSA Method GS1/2/3 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Fit the polarimeter with the correct tube length and clean, bubble-free sample cells, and allow temperature equilibration before reading. Standardize the instrument with a certified quartz plate or a reference standard at the working wavelength and temperature, and record the result. Keep polarizers and windows clean to avoid stray light and scattering errors. Prepare samples at known concentration and temperature, and note the solvent because specific rotation depends on it. Service and recalibrate periodically, and verify the sodium lamp or light-emitting diode output, since wavelength drift biases results.
How do I select the right Multi-Wavelength Polarimeter?
Select a multi-wavelength polarimeter for research or for samples where the single sodium D line is insufficiently selective. Confirm that the available wavelengths include those required by the methods in use, and that temperature control and software support the intended studies. For routine single-wavelength assays, a standard automatic polarimeter is sufficient and more economical.
How does it compare with other Polarimeters variants?
Choose the polarimeter type according to the application. Sugar analysis uses a saccharimeter reading in sugar degrees, while chiral pharmaceutical testing uses an automatic polarimeter reading in angular degrees and often several wavelengths. Manual instruments suit teaching and occasional measurement where budget is limited. Where temperature-sensitive substances are tested, select a model with Peltier temperature control. Confirm the required resolution, accuracy and tube length, and whether sample tubes or flow cells are needed. For regulatory work, check that the wavelength, temperature and data records match pharmacopoeial requirements, and that the instrument supports audit trails and controlled user access.
Full specifications
| Measurement scale | ±90° optical rotation |
|---|---|
| Wavelengths | 365, 405, 436, 546, 589, 633 nm |
| Resolution | 0.001° |
| Accuracy | ±0.01° |
| Light source | LED or xenon lamp with filters |
| Temperature control | 20 °C ± 0.2 °C, Peltier |
| Sample tubes | 100 mm and 200 mm |
| Display | LCD |
| Data interface | USB, RS-232 |
| Power supply | 100–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Pharmaceutical chiral research and development
- Natural product and flavour analysis
- Optical rotatory dispersion studies
- Purity assessment of optically active compounds
Key features
- Multiple selectable measuring wavelengths
- Optical rotatory dispersion measurement
- Photoelectric detection with temperature control
- Software for multi-wavelength comparison
- Improved selectivity for closely related substances
Frequently asked questions about Multi-Wavelength Polarimeter
Optical rotatory dispersion is the change of optical rotation with wavelength. Measuring rotation at several wavelengths produces a dispersion curve that depends on the structure of the compound, which helps identify or differentiate closely related chiral substances beyond a single-wavelength reading.
It is preferable when a single wavelength gives poor discrimination, when the sample absorbs strongly at the usual wavelength, or when structural information is needed. Routine pharmacopoeial assays usually specify one wavelength, so a multi-wavelength instrument is unnecessary for those methods.
The wavelength scale and detector response should be verified at each wavelength used, because filters and sources differ. Standardization with certified quartz plates at the working wavelengths confirms that readings are accurate across the range.
A polarimeter measures the angle by which an optically active sample rotates the plane of polarized light. From the measured rotation, the path length and the specific rotation of the substance, the concentration can be calculated. It also detects the presence of chiral compounds.
Optical rotation depends strongly on wavelength, a phenomenon called optical rotatory dispersion. Broad-band light would give an averaged and unstable reading, so a single wavelength is used, most commonly the sodium D line at 589 nm, as specified in pharmacopoeial methods.
A polarimeter reports optical rotation in angular degrees, while a saccharimeter is calibrated in sugar degrees, denoted °Z, using the international sugar scale. Saccharimeters are used mainly in sugar and food analysis, where results are expressed directly as sucrose content.
Related models