Gem Refractometer
宝石折光仪
- SKU RFR-0005
- Refractometers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement range | 1.30–1.81 nD |
|---|---|
| Accuracy | ±0.002 nD |
| Reference wavelength | 589 nm |
| Light source | Monochromatic LED or sodium lamp |
| Contact liquid index | 1.81 |
| Polarizing filter | Included in eyepiece |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <831>, Ph. Eur. 2.2.6, ISO 2173
What is the Gem Refractometer?
A gem refractometer measures the refractive index of gemstones to aid identification. Its high index range and contact-liquid method make it a core instrument in gemmological laboratories and in routine jewellery trade testing.
What is the Gem Refractometer?
A gem refractometer measures the refractive index of gemstones to aid identification. Its high index range and contact-liquid method make it a core instrument in gemmological laboratories and in routine jewellery trade testing.
Overview
A gem refractometer places a polished facet of a stone on a high-index prism with a drop of contact liquid to ensure optical contact. The critical angle is observed through a polarizing eyepiece under monochromatic light, and the refractive index is read from a scale. The high range, often up to 1.81 or beyond, covers most gem materials, and birefringence can be seen as a doubling of the shadow edge when the stone is rotated. The polarizing filter helps distinguish isotropic from anisotropic stones. The contact liquid is chosen so its index is higher than the stone being tested. The method requires a flat facet and careful technique.
How does it work?
A refractometer measures the angle at which light is refracted or totally internally reflected at the boundary between a prism and the sample. In the critical-angle design, light passes through the sample and prism, and the boundary between the bright and dark fields gives the critical angle, which corresponds to the refractive index of the sample. In the grazing-incidence or reflection design, light reflects at a shallow angle to measure the index directly. Refractive index depends strongly on wavelength, so measurements are referenced to the sodium D line at 589 nm, and on temperature, so instruments include temperature control or compensation. The measured index is converted to concentration, commonly expressed as Brix for sugar solutions.
What are the key features?
- High refractive index range for gem materials
- Contact-liquid coupling for optical contact
- Polarizing eyepiece for isotropic and anisotropic stones
- Monochromatic light source for a sharp shadow edge
- Birefringence observation by rotating the stone
What are the technical specifications?
A typical gem refractometer configuration offers measurement range of 1.30–1.81 nD, accuracy of ±0.002 nD, reference wavelength of 589 nm, light source of Monochromatic LED or sodium lamp, contact liquid index of 1.81 and polarizing filter of Included in eyepiece. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Gem Refractometer is used in gemstone identification and verification, jewellery trade and appraisal testing, diamond simulant differentiation and teaching and gemmological research. Across the wider Refractometers class, laboratories also deploy it for food and beverage sugar content testing, pharmaceutical liquid identity and purity and chemical concentration and purity checks.
Which standards and certifications apply?
Relevant standards and methods include USP <831>, Ph. Eur. 2.2.6, ISO 2173, ASTM D1218 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Clean and dry the prism before and after each measurement, and apply the sample as a thin, even film covering the whole prism surface. Avoid scratching the prism with hard particles. Control temperature, since refractive index changes about 0.00045 per degree Celsius for water, and allow the sample to equilibrate. Standardize with distilled water or certified reference liquids and record the value. For Brix scales, note that the scale assumes a pure sucrose solution, so other dissolved solids may bias the reading. Keep prisms and seals in good condition, and recalibrate on a defined schedule.
How do I select the right Gem Refractometer?
Select a gem refractometer for gemstone refractive index measurement in gemmological testing. Confirm the index range covers the stones of interest, and that the contact liquid supplied has a suitable index. For stones with no flat facet or with indices above the prism range, other methods are needed. Handle contact liquid with care as it can stain or damage some materials.
How does it compare with other Refractometers variants?
Choose the design according to the measurement point. Handheld refractometers suit field and quick checks of fruit, beverages and process liquids, using ambient light and automatic temperature compensation. Benchtop Abbe refractometers provide controlled temperature and higher accuracy for laboratory methods. Automatic digital refractometers add electronic readout, temperature control and data output for regulated work. Inline process refractometers measure continuously through a pipeline for plant control. For gems, a refractometer with high index range and contact liquid is used. Confirm range, accuracy, temperature control and whether Brix or refractive index readout is required.
Full specifications
| Measurement range | 1.30–1.81 nD |
|---|---|
| Accuracy | ±0.002 nD |
| Reference wavelength | 589 nm |
| Light source | Monochromatic LED or sodium lamp |
| Contact liquid index | 1.81 |
| Polarizing filter | Included in eyepiece |
| Prism material | High-index glass |
| Scale graduation | 0.01 nD |
| Eyepiece | Focusable with scale |
| Power supply | Battery or mains adapter |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Gemstone identification and verification
- Jewellery trade and appraisal testing
- Diamond simulant differentiation
- Teaching and gemmological research
Key features
- High refractive index range for gem materials
- Contact-liquid coupling for optical contact
- Polarizing eyepiece for isotropic and anisotropic stones
- Monochromatic light source for a sharp shadow edge
- Birefringence observation by rotating the stone
Frequently asked questions about Gem Refractometer
Contact liquid, also called refractive index liquid, fills the gap between the stone facet and the prism so that light passes between them without total internal reflection at the air gap. Its refractive index must be higher than that of the stone being tested for the shadow edge to be visible.
A doubled shadow edge indicates birefringence, meaning the stone is anisotropic and splits light into two rays with different refractive indices. This helps identify crystal systems and distinguishes many gems from glass, which is isotropic and shows a single edge.
The method needs a flat polished facet and a refractive index within the prism range. Stones cut as cabochons, set in jewellery or with indices above the range cannot be measured directly. In those cases, reflectivity or other methods are used instead.
Brix is a scale expressing the dissolved solids content of a solution as the equivalent percentage of sucrose by mass. It is derived from refractive index using a defined table at a stated temperature. Brix is widely used in food and beverage testing for sugar content.
Refractive index changes with temperature, typically by about 0.00045 per degree Celsius for aqueous solutions. Readings are referenced to 20 °C or 25 °C, and instruments compensate or control temperature. Without this, small temperature differences cause significant concentration errors on the Brix scale.
An Abbe refractometer uses a visual or scale-based observation of the critical angle and usually a water-jacketed prism for temperature control. A digital refractometer uses an electronic sensor and displays the result directly, often with automatic temperature control and data output, giving better repeatability and easier documentation.