Automatic Polarimeter
自动旋光仪
- SKU PLR-0001
- Polarimeters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement scale | ±90° optical rotation |
|---|---|
| Resolution | 0.001° |
| Accuracy | ±0.01° |
| Measuring wavelength | 589 nm |
| Light source | LED or sodium lamp |
| Temperature control | 20 °C ± 0.2 °C, Peltier |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <781>, Ph. Eur. 2.2.7, JP 2.49
What is the Automatic Polarimeter?
An automatic polarimeter measures optical rotation photoelectrically and displays the result digitally. It replaces visual judgment with a detector and motor, giving better repeatability and making it the standard instrument for routine pharmaceutical and food testing.
What is the Automatic Polarimeter?
An automatic polarimeter measures optical rotation photoelectrically and displays the result digitally. It replaces visual judgment with a detector and motor, giving better repeatability and making it the standard instrument for routine pharmaceutical and food testing.
Overview
An automatic polarimeter uses a polarized light source, a sample compartment and a photoelectric detection system to measure rotation without operator judgment. A servomotor or Faraday modulator rotates the analyser until the detected light is at a null or balanced position, and the angle is read from the encoder. Digital processing provides high resolution, automatic averaging and direct calculation of specific rotation or concentration after the sample concentration is entered. Temperature control by Peltier elements keeps the sample at the specified temperature. Results and settings can be printed or exported, and user access controls support regulated environments.
How does it work?
A polarimeter passes light through a polarizer to produce plane-polarized light, then through a sample cell containing an optically active substance. The sample rotates the plane of polarization by an amount proportional to its concentration, path length and specific rotation. An analyser measures the rotation angle, historically by eye against a vernier scale and now by photoelectric detection with a servomotor or Faraday modulator. Monochromatic light is essential because optical rotation depends strongly on wavelength; the sodium D line at 589 nm is the conventional reference. Temperature control matters because specific rotation changes with temperature. The measured rotation is converted to concentration using the specific rotation and path length.
What are the key features?
- Photoelectric detection with servo or modulator nulling
- Digital readout with direct specific rotation calculation
- Peltier temperature control of the sample
- Automatic averaging for improved repeatability
- Data export and user access control for compliance
What are the technical specifications?
A typical automatic polarimeter configuration offers measurement scale of ±90° optical rotation, resolution of 0.001°, accuracy of ±0.01°, measuring wavelength of 589 nm, light source of LED or sodium lamp and temperature control of 20 °C ± 0.2 °C, Peltier. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automatic Polarimeter is used in pharmaceutical identity and assay testing, chiral purity determination, sugar and syrup analysis and flavour and essential oil quality control. Across the wider Polarimeters class, laboratories also deploy it for pharmaceutical chiral purity and assay, sugar and sweetener analysis and essential oil and flavour authentication.
Which standards and certifications apply?
Relevant standards and methods include USP <781>, Ph. Eur. 2.2.7, JP 2.49, ICUMSA Method GS1/2/3 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Fit the polarimeter with the correct tube length and clean, bubble-free sample cells, and allow temperature equilibration before reading. Standardize the instrument with a certified quartz plate or a reference standard at the working wavelength and temperature, and record the result. Keep polarizers and windows clean to avoid stray light and scattering errors. Prepare samples at known concentration and temperature, and note the solvent because specific rotation depends on it. Service and recalibrate periodically, and verify the sodium lamp or light-emitting diode output, since wavelength drift biases results.
How do I select the right Automatic Polarimeter?
Choose an automatic polarimeter for routine, repeatable optical rotation measurement in regulated or high-throughput laboratories. Confirm the wavelength matches the method, the resolution and accuracy meet the specification, and temperature control covers the working range. For pharmacopoeial testing, verify that software provides the required data records and access control.
How does it compare with other Polarimeters variants?
Choose the polarimeter type according to the application. Sugar analysis uses a saccharimeter reading in sugar degrees, while chiral pharmaceutical testing uses an automatic polarimeter reading in angular degrees and often several wavelengths. Manual instruments suit teaching and occasional measurement where budget is limited. Where temperature-sensitive substances are tested, select a model with Peltier temperature control. Confirm the required resolution, accuracy and tube length, and whether sample tubes or flow cells are needed. For regulatory work, check that the wavelength, temperature and data records match pharmacopoeial requirements, and that the instrument supports audit trails and controlled user access.
Full specifications
| Measurement scale | ±90° optical rotation |
|---|---|
| Resolution | 0.001° |
| Accuracy | ±0.01° |
| Measuring wavelength | 589 nm |
| Light source | LED or sodium lamp |
| Temperature control | 20 °C ± 0.2 °C, Peltier |
| Sample tubes | 100 mm and 200 mm |
| Display | LCD |
| Data interface | USB, RS-232 |
| Power supply | 100–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Pharmaceutical identity and assay testing
- Chiral purity determination
- Sugar and syrup analysis
- Flavour and essential oil quality control
Key features
- Photoelectric detection with servo or modulator nulling
- Digital readout with direct specific rotation calculation
- Peltier temperature control of the sample
- Automatic averaging for improved repeatability
- Data export and user access control for compliance
Frequently asked questions about Automatic Polarimeter
It replaces the operator's visual comparison with a photoelectric detector and motor, so the null point is found consistently and the angle is read from a digital encoder. Automatic averaging of several readings further reduces random error, giving repeatability that manual instruments cannot match.
Standard polarimeter tubes of 100 mm and 200 mm path length are commonly used, with longer tubes giving greater rotation for low-concentration samples. Tubes must be clean and bubble-free, and the path length and temperature entered into the calculation for accurate specific rotation.
Yes, when the specific rotation and sample concentration or path length are entered, the polarimeter computes specific rotation or concentration directly. This reduces calculation errors, but the specific rotation value must be appropriate for the solvent, wavelength and temperature used.
A polarimeter measures the angle by which an optically active sample rotates the plane of polarized light. From the measured rotation, the path length and the specific rotation of the substance, the concentration can be calculated. It also detects the presence of chiral compounds.
Optical rotation depends strongly on wavelength, a phenomenon called optical rotatory dispersion. Broad-band light would give an averaged and unstable reading, so a single wavelength is used, most commonly the sodium D line at 589 nm, as specified in pharmacopoeial methods.
A polarimeter reports optical rotation in angular degrees, while a saccharimeter is calibrated in sugar degrees, denoted °Z, using the international sugar scale. Saccharimeters are used mainly in sugar and food analysis, where results are expressed directly as sucrose content.
Related models