High-Temperature Glass Bead Sterilizer
高温玻璃珠灭菌器
- SKU GBS-0002
- Glass Bead Sterilizers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- EN 61010-1 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Working temperature | 300-350 °C |
|---|---|
| Temperature stability | ±5 °C at 300 °C |
| Typical hold time | 5-10 s per instrument |
| Warm-up time to 300 °C | 25-40 min |
| Well diameter | 40-70 mm |
| Well depth | 50-90 mm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 61010-1, EN 61010-2-010, ISO 11138-1
What is the High-Temperature Glass Bead Sterilizer?
A bead sterilizer that reaches 300 °C or higher so instruments need shorter hold times, typically 5 to 10 seconds. It suits laboratories that process many small metal tools per session and need fast bed recovery.
What is the High-Temperature Glass Bead Sterilizer?
A bead sterilizer that reaches 300 °C or higher so instruments need shorter hold times, typically 5 to 10 seconds. It suits laboratories that process many small metal tools per session and need fast bed recovery.
Overview
The high-temperature bead sterilizer uses a higher-rated heating element, thicker insulation and a stainless steel well that tolerates 300 to 350 °C without scaling. Higher bed temperature shortens the contact time needed for surface kill and speeds recovery after an instrument is inserted, which matters when many items are handled in a short period. The thermostat has a wider range and usually a digital controller with an over-temperature cut-out, since 300 °C approaches the limits of bead material and insulation. Beads may be borosilicate rather than soda-lime to limit sticking and devitrification. The outer case needs adequate ventilation because heat loss is greater. Operators still work in seconds, but burning of residues is more complete, which reduces char build-up in the bed.
How does it work?
Glass bead sterilization works by thermal conduction. A well in the unit holds soda-lime or borosilicate beads of about 1.5 to 4 mm diameter, and a resistive heating element raises them to the set temperature, commonly 250 °C. The bead bed has a high thermal mass, so when a small instrument is pushed into it the beads transfer heat directly to the metal and surface microorganisms are killed by dry heat within 10 to 30 seconds. A thermocouple or platinum sensor in the well feeds a controller that switches the heater and holds the temperature, while a timer or indicator lamp shows when the unit is ready. Insulation around the well limits heat loss and keeps the outer case cool. Because heat reaches only the surfaces touching the beads, deep lumens and hinges may stay unsterilized.
What are the key features?
- Working temperature of 300 °C or higher for shorter hold times.
- Wider-range digital controller with over-temperature cut-out.
- Thicker insulation for faster recovery between insertions.
- Borosilicate bead option to reduce sticking and devitrification.
- Ventilated case that handles higher heat loss.
- Improved burning of residues to limit char build-up.
What are the technical specifications?
A typical high-temperature glass bead sterilizer configuration offers working temperature of 300-350 °C, temperature stability of ±5 °C at 300 °C, typical hold time of 5-10 s per instrument, warm-up time to 300 °C of 25-40 min, well diameter of 40-70 mm and well depth of 50-90 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Temperature Glass Bead Sterilizer is used in high-volume bench workflows, forceps sterilization in animal facilities, dental clinic instrument turnover and loop sterilization in busy microbiology laboratories. Across the wider Glass Bead Sterilizers class, laboratories also deploy it for rapid sterilization of forceps and scissors, inoculating loop and needle sterilization and animal research instrument sterilization.
Which standards and certifications apply?
Relevant standards and methods include EN 61010-1, EN 61010-2-010, ISO 11138-1, GB 4793.1 and ISO 9001 manufacturing. Certification candidates for this model are CE, ISO 9001 manufacturing and EN 61010-1 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the unit on a heat-resistant bench away from flammable materials and leave at least 10 cm clearance on all sides. Use a dedicated socket, since benchtop units typically draw 100 to 300 W. Verify the bed temperature with an external thermometer at installation and annually afterwards, because a drifting thermostat can leave the bed below the effective temperature. Keep the bed filled to the marked level, as low beads reduce contact and overheat the element. Remove debris and metal chips with a sieve, and replace beads when they discolor, crack or sinter. Wear heat-resistant gloves when inserting instruments and never place solvent bottles near the well.
How do I select the right High-Temperature Glass Bead Sterilizer?
Choose the high-temperature variant when many instruments are handled in a short time and short hold times matter, or when residues must burn off more completely. Confirm that the instruments and any coatings tolerate 300 °C, since thin blades and some alloys may soften or discolor. Ask about bead material, controller accuracy, over-temperature protection and spare element availability.
How does it compare with other Glass Bead Sterilizers variants?
Choose a glass bead sterilizer when small metal tools must be re-used quickly between bench steps, not when packaged loads, liquids or lumens need sterilization. Compare the well diameter and depth with the length of your instruments, because long forceps must reach the bead bed without the handle becoming too hot. Check the maximum temperature, the warm-up time and the recovery time after each insertion. A digital temperature display and timer make routine use more consistent than a simple indicator lamp. For heavy use, two wells or two units avoid waiting during warm-up. Confirm the bead size, the availability of replacement bead packs and whether a basket or heat shield is included.
Full specifications
| Working temperature | 300-350 °C |
|---|---|
| Temperature stability | ±5 °C at 300 °C |
| Typical hold time | 5-10 s per instrument |
| Warm-up time to 300 °C | 25-40 min |
| Well diameter | 40-70 mm |
| Well depth | 50-90 mm |
| Glass bead material | Borosilicate, 1.5-4 mm |
| Bead capacity | 150-300 g |
| Safety devices | Over-temperature cut-out, thermal fuse |
| Power supply | 220 V, 50 Hz, 150-400 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-volume bench workflows
- Forceps sterilization in animal facilities
- Dental clinic instrument turnover
- Loop sterilization in busy microbiology laboratories
Key features
- Working temperature of 300 °C or higher for shorter hold times.
- Wider-range digital controller with over-temperature cut-out.
- Thicker insulation for faster recovery between insertions.
- Borosilicate bead option to reduce sticking and devitrification.
- Ventilated case that handles higher heat loss.
- Improved burning of residues to limit char build-up.
Frequently asked questions about High-Temperature Glass Bead Sterilizer
It is faster, not automatically safer. The shorter hold time and faster recovery reduce the chance of an under-temperature cycle, but instruments must tolerate the higher temperature and the method still sterilizes surfaces only.
Soda-lime beads age faster at 300 °C, sticking and clouding sooner. Borosilicate beads last longer at that temperature, so check which material is supplied and budget for more frequent replacement.
Only small metal items that tolerate 300 °C. Plastic handles, soldered joints, fine spring steel and any item with a polymer coating should not be inserted, because they deform, lose temper or release fumes.
Small instruments are held in the heated beads for about 10 to 30 seconds at 250 °C. Thin items such as loops and needles need the shorter time, while hinged forceps and scissors may need 20 to 30 seconds. Between insertions, allow the bed to recover to the set temperature.
Typical units hold 250 °C, and high-temperature versions reach 300 °C or more. Hold times of 10 to 30 seconds are used for small metal instruments. Confirm the actual bed temperature with an external probe, because displayed values can drift over time.
No. The method depends on direct contact between hot beads and metal surfaces. Liquids would boil or spill, and plastics soften or melt. Use an autoclave for liquids, media and wrapped goods, and keep bead sterilizers for small metal items only.
Related models