Portable Glass Bead Sterilizer
便携式玻璃珠灭菌器
- SKU GBS-0004
- Glass Bead Sterilizers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Working temperature | 250 °C nominal |
|---|---|
| Bead capacity | 30-80 g |
| Well diameter | 25-45 mm |
| Well depth | 30-60 mm |
| Warm-up time to 250 °C | 10-20 min |
| Power options | 220 V mains, 12 V DC, battery pack |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 61010-1, EN 61010-2-010, ISO 11138-1
What is the Portable Glass Bead Sterilizer?
A compact, low-power bead sterilizer that can be carried between benches or used in field stations, usually with a 12 V or battery option. It provides short-cycle surface sterilization where an autoclave is unavailable.
What is the Portable Glass Bead Sterilizer?
A compact, low-power bead sterilizer that can be carried between benches or used in field stations, usually with a 12 V or battery option. It provides short-cycle surface sterilization where an autoclave is unavailable.
Overview
The portable bead sterilizer shrinks the well, insulation and electronics into a small case of 1 to 3 kg, with wells that hold 30 to 80 g of beads. Lower bead mass means faster warm-up, often 10 to 20 minutes, but also faster cooling after each insertion, so hold times are chosen conservatively. Power options include 220 V mains for bench use, 12 V for vehicles and rechargeable lithium or sealed lead-acid battery packs for field work. Insulation is efficient so that exterior surfaces stay touchable, and a lid reduces heat loss during transport. Because the bed is small, only loops, needles, small scissors and forceps fit. A simple dial or a small digital readout sets the temperature, and a case-mounted handle or shoulder strap aids carrying.
How does it work?
Glass bead sterilization works by thermal conduction. A well in the unit holds soda-lime or borosilicate beads of about 1.5 to 4 mm diameter, and a resistive heating element raises them to the set temperature, commonly 250 °C. The bead bed has a high thermal mass, so when a small instrument is pushed into it the beads transfer heat directly to the metal and surface microorganisms are killed by dry heat within 10 to 30 seconds. A thermocouple or platinum sensor in the well feeds a controller that switches the heater and holds the temperature, while a timer or indicator lamp shows when the unit is ready. Insulation around the well limits heat loss and keeps the outer case cool. Because heat reaches only the surfaces touching the beads, deep lumens and hinges may stay unsterilized.
What are the key features?
- Compact 1 to 3 kg case with handle or shoulder strap.
- Mains, 12 V vehicle and battery power options.
- Low bead mass for 10 to 20 minute warm-up.
- Insulated case with lid to retain heat in transit.
- Simple dial or small digital temperature readout.
- Suited to loops, needles and small forceps only.
What are the technical specifications?
A typical portable glass bead sterilizer configuration offers working temperature of 250 °C nominal, bead capacity of 30-80 g, well diameter of 25-45 mm, well depth of 30-60 mm, warm-up time to 250 °C of 10-20 min and power options of 220 V mains, 12 V DC, battery pack. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Portable Glass Bead Sterilizer is used in field and mobile laboratories, veterinary and animal field work, satellite benches without an autoclave and teaching demonstrations away from the main laboratory. Across the wider Glass Bead Sterilizers class, laboratories also deploy it for rapid sterilization of forceps and scissors, inoculating loop and needle sterilization and animal research instrument sterilization.
Which standards and certifications apply?
Relevant standards and methods include EN 61010-1, EN 61010-2-010, ISO 11138-1, GB 4793.1 and ISO 9001 manufacturing. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the unit on a heat-resistant bench away from flammable materials and leave at least 10 cm clearance on all sides. Use a dedicated socket, since benchtop units typically draw 100 to 300 W. Verify the bed temperature with an external thermometer at installation and annually afterwards, because a drifting thermostat can leave the bed below the effective temperature. Keep the bed filled to the marked level, as low beads reduce contact and overheat the element. Remove debris and metal chips with a sieve, and replace beads when they discolor, crack or sinter. Wear heat-resistant gloves when inserting instruments and never place solvent bottles near the well.
How do I select the right Portable Glass Bead Sterilizer?
Select the portable variant when the sterilizer must move between rooms, sites or vehicles, or when mains power is unreliable. Accept the smaller well and check that your longest instrument fits. Specify the power options needed, battery runtime, warm-up expectation and whether a carry case or vehicle adapter is included in the quotation.
How does it compare with other Glass Bead Sterilizers variants?
Choose a glass bead sterilizer when small metal tools must be re-used quickly between bench steps, not when packaged loads, liquids or lumens need sterilization. Compare the well diameter and depth with the length of your instruments, because long forceps must reach the bead bed without the handle becoming too hot. Check the maximum temperature, the warm-up time and the recovery time after each insertion. A digital temperature display and timer make routine use more consistent than a simple indicator lamp. For heavy use, two wells or two units avoid waiting during warm-up. Confirm the bead size, the availability of replacement bead packs and whether a basket or heat shield is included.
Full specifications
| Working temperature | 250 °C nominal |
|---|---|
| Bead capacity | 30-80 g |
| Well diameter | 25-45 mm |
| Well depth | 30-60 mm |
| Warm-up time to 250 °C | 10-20 min |
| Power options | 220 V mains, 12 V DC, battery pack |
| Battery runtime | 2-4 h with insulated lid |
| Net weight | 1-3 kg |
| Temperature control | Dial thermostat or digital controller |
| Case material | Stainless steel inner case, insulated outer shell |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Field and mobile laboratories
- Veterinary and animal field work
- Satellite benches without an autoclave
- Teaching demonstrations away from the main laboratory
Key features
- Compact 1 to 3 kg case with handle or shoulder strap.
- Mains, 12 V vehicle and battery power options.
- Low bead mass for 10 to 20 minute warm-up.
- Insulated case with lid to retain heat in transit.
- Simple dial or small digital temperature readout.
- Suited to loops, needles and small forceps only.
Frequently asked questions about Portable Glass Bead Sterilizer
Only if throughput is low. The small bead bed cools quickly after each insertion, so cycles take longer per instrument. For continuous bench work, a mains-powered single or double-well unit is a better choice.
Typically two to four hours of holding temperature, depending on ambient conditions and how often the lid is opened. Warm-up from cold consumes the most power, so pre-heat before leaving a mains supply.
The outer case is usually designed to stay touchable, but it can become warm after long holding periods. Place it on a heat-resistant surface, avoid running it on a lap or inside a plastic case, and follow the manufacturer's surface temperature limits.
Small instruments are held in the heated beads for about 10 to 30 seconds at 250 °C. Thin items such as loops and needles need the shorter time, while hinged forceps and scissors may need 20 to 30 seconds. Between insertions, allow the bed to recover to the set temperature.
Typical units hold 250 °C, and high-temperature versions reach 300 °C or more. Hold times of 10 to 30 seconds are used for small metal instruments. Confirm the actual bed temperature with an external probe, because displayed values can drift over time.
No. The method depends on direct contact between hot beads and metal surfaces. Liquids would boil or spill, and plastics soften or melt. Use an autoclave for liquids, media and wrapped goods, and keep bead sterilizers for small metal items only.