Large-Capacity Glass Bead Sterilizer
大容量玻璃珠灭菌器
- SKU GBS-0005
- Glass Bead Sterilizers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- EN 61010-1 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Working temperature | 250-300 °C |
|---|---|
| Well diameter | 70-100 mm |
| Well depth | 90-150 mm |
| Bead capacity | 300-800 g |
| Recovery time after insertion | 5-15 s |
| Warm-up time to 250 °C | 30-50 min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 61010-1, EN 61010-2-010, ISO 11138-1
What is the Large-Capacity Glass Bead Sterilizer?
A bead sterilizer with a deeper or wider well holding 300 g or more of beads, sized for long forceps, spatulas and heavier instruments. It keeps recovery time short when large metal items are processed repeatedly.
What is the Large-Capacity Glass Bead Sterilizer?
A bead sterilizer with a deeper or wider well holding 300 g or more of beads, sized for long forceps, spatulas and heavier instruments. It keeps recovery time short when large metal items are processed repeatedly.
Overview
The large-capacity sterilizer increases well diameter to 70 to 100 mm and depth to 90 to 150 mm so that 20 cm forceps, long spatulas, scissors and bone cutters can be embedded to the required depth. Bead mass of 300 to 800 g gives a larger thermal reservoir, which limits the temperature drop when a cold instrument is inserted and shortens recovery to a few seconds. Higher heater power, typically 300 to 600 W, compensates for the greater mass and the larger exposed surface area. Some models add a second element in the base and a fan-assisted or fully insulated lid. Because the well is deeper, the operator must control insertion depth to avoid overheating handles. An adjustable stop bar or a marked insertion line is common.
How does it work?
Glass bead sterilization works by thermal conduction. A well in the unit holds soda-lime or borosilicate beads of about 1.5 to 4 mm diameter, and a resistive heating element raises them to the set temperature, commonly 250 °C. The bead bed has a high thermal mass, so when a small instrument is pushed into it the beads transfer heat directly to the metal and surface microorganisms are killed by dry heat within 10 to 30 seconds. A thermocouple or platinum sensor in the well feeds a controller that switches the heater and holds the temperature, while a timer or indicator lamp shows when the unit is ready. Insulation around the well limits heat loss and keeps the outer case cool. Because heat reaches only the surfaces touching the beads, deep lumens and hinges may stay unsterilized.
What are the key features?
- Well diameter of 70 to 100 mm for long forceps and spatulas.
- Bead capacity of 300 to 800 g for a large thermal reservoir.
- Heater power of 300 to 600 W for fast recovery.
- Optional second heating element in the well base.
- Adjustable stop bar to control insertion depth.
- Fully insulated lid to hold temperature between uses.
What are the technical specifications?
A typical large-capacity glass bead sterilizer configuration offers working temperature of 250-300 °C, well diameter of 70-100 mm, well depth of 90-150 mm, bead capacity of 300-800 g, recovery time after insertion of 5-15 s and warm-up time to 250 °C of 30-50 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Large-Capacity Glass Bead Sterilizer is used in long forceps and spatula sterilization, large animal surgery instrument preparation, histology and pathology tool sterilization and industrial quality control benches. Across the wider Glass Bead Sterilizers class, laboratories also deploy it for rapid sterilization of forceps and scissors, inoculating loop and needle sterilization and animal research instrument sterilization.
Which standards and certifications apply?
Relevant standards and methods include EN 61010-1, EN 61010-2-010, ISO 11138-1, GB 4793.1 and ISO 9001 manufacturing. Certification candidates for this model are CE, ISO 9001 manufacturing and EN 61010-1 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the unit on a heat-resistant bench away from flammable materials and leave at least 10 cm clearance on all sides. Use a dedicated socket, since benchtop units typically draw 100 to 300 W. Verify the bed temperature with an external thermometer at installation and annually afterwards, because a drifting thermostat can leave the bed below the effective temperature. Keep the bed filled to the marked level, as low beads reduce contact and overheat the element. Remove debris and metal chips with a sieve, and replace beads when they discolor, crack or sinter. Wear heat-resistant gloves when inserting instruments and never place solvent bottles near the well.
How do I select the right Large-Capacity Glass Bead Sterilizer?
Select the large-capacity model when your instruments are longer than about 15 cm or heavier than a standard loop, or when recovery time directly limits throughput. Measure the longest tool that must touch the bed and add 20 mm of margin. Specify well diameter and depth, bead mass, heater power, maximum temperature and any depth-stop accessory in the RFQ.
How does it compare with other Glass Bead Sterilizers variants?
Choose a glass bead sterilizer when small metal tools must be re-used quickly between bench steps, not when packaged loads, liquids or lumens need sterilization. Compare the well diameter and depth with the length of your instruments, because long forceps must reach the bead bed without the handle becoming too hot. Check the maximum temperature, the warm-up time and the recovery time after each insertion. A digital temperature display and timer make routine use more consistent than a simple indicator lamp. For heavy use, two wells or two units avoid waiting during warm-up. Confirm the bead size, the availability of replacement bead packs and whether a basket or heat shield is included.
Full specifications
| Working temperature | 250-300 °C |
|---|---|
| Well diameter | 70-100 mm |
| Well depth | 90-150 mm |
| Bead capacity | 300-800 g |
| Recovery time after insertion | 5-15 s |
| Warm-up time to 250 °C | 30-50 min |
| Maximum instrument length | Up to 250 mm |
| Temperature control | PID controller with digital display |
| Safety devices | Over-temperature cut-out, insulated lid interlock option |
| Power supply | 220 V, 50 Hz, 300-600 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Long forceps and spatula sterilization
- Large animal surgery instrument preparation
- Histology and pathology tool sterilization
- Industrial quality control benches
Key features
- Well diameter of 70 to 100 mm for long forceps and spatulas.
- Bead capacity of 300 to 800 g for a large thermal reservoir.
- Heater power of 300 to 600 W for fast recovery.
- Optional second heating element in the well base.
- Adjustable stop bar to control insertion depth.
- Fully insulated lid to hold temperature between uses.
Frequently asked questions about Large-Capacity Glass Bead Sterilizer
After a cold instrument is inserted, the bed temperature drops and must return to set point before the next item. With a large bead mass and sufficient heater power, recovery takes only a few seconds, keeping a multi-instrument cycle on schedule.
It can if instruments are pushed in fully. Use the adjustable stop bar or the marked line to set insertion depth, and allow only the working portion of the instrument to contact the bead bed.
Yes. A 300 to 800 g bead bed needs 300 to 600 W to heat in a reasonable time and to recover after insertion. Check that a dedicated circuit is available before ordering.
Small instruments are held in the heated beads for about 10 to 30 seconds at 250 °C. Thin items such as loops and needles need the shorter time, while hinged forceps and scissors may need 20 to 30 seconds. Between insertions, allow the bed to recover to the set temperature.
Typical units hold 250 °C, and high-temperature versions reach 300 °C or more. Hold times of 10 to 30 seconds are used for small metal instruments. Confirm the actual bed temperature with an external probe, because displayed values can drift over time.
No. The method depends on direct contact between hot beads and metal surfaces. Liquids would boil or spill, and plastics soften or melt. Use an autoclave for liquids, media and wrapped goods, and keep bead sterilizers for small metal items only.
Related models