UV Sterilization Cabinet
紫外灭菌柜
- SKU UVS-0001
- UV Sterilizers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 62471 photobiological safety report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 50-500 L |
|---|---|
| Lamp type | Low-pressure mercury, 253.7 nm |
| Lamp power | 8-40 W per lamp |
| Number of lamps | 1-4 |
| Timer range | 1-60 min |
| Typical surface dose | 30-100 mJ/cm² per cycle |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 62471, IEC 61010-1, GB 19258
What is the UV Sterilization Cabinet?
A closed stainless steel cabinet with UV-C lamps and a timer that disinfects small instruments, glassware, pipettes and reusable personal protective equipment. It is used where heat or wet methods are unsuitable or unavailable.
What is the UV Sterilization Cabinet?
A closed stainless steel cabinet with UV-C lamps and a timer that disinfects small instruments, glassware, pipettes and reusable personal protective equipment. It is used where heat or wet methods are unsuitable or unavailable.
Overview
The UV sterilization cabinet is a light-tight enclosure, usually 50 to 500 L, with a reflective stainless steel interior and one to four 253.7 nm low-pressure mercury lamps of 8 to 40 W. Items are placed on wire shelves or a tray and irradiated for a set period, commonly 15 to 30 minutes, while a door switch or mechanical interlock prevents the lamps from operating when the door is open. A mechanical or digital timer controls the cycle, and some models add a small fan or a heated circulation stage during the irradiation period. Optional features include quartz glass trays, which transmit UV-C, and wall-mounting brackets. Because UV light does not penetrate, the cabinet suits tools, masks, goggles, keyboards and small parts with exposed surfaces, and it is often used alongside, not instead of, an autoclave.
How does it work?
Ultraviolet sterilization uses UV-C light, emitted mainly at 253.7 nm by low-pressure mercury lamps, which nucleic acids absorb so that pyrimidine dimers form and block replication. Efficacy depends on dose, the product of irradiance in µW/cm² and exposure time in seconds, expressed in mJ/cm². Germicidal cabinets place items on a reflective stainless steel tray below one or more lamps and run a timed cycle of 5 to 60 minutes. Air sterilizers draw room air through a chamber with lamps and baffles so the moving air receives the required dose while people remain outside the direct beam. Water units pass the flow around quartz-sleeved lamps. Because UV light travels in straight lines, only surfaces in direct view are treated, so shadowed, covered or dusty areas are not disinfected.
What are the key features?
- Light-tight stainless cabinet of 50 to 500 L with reflective interior.
- One to four 253.7 nm lamps of 8 to 40 W.
- Door switch or interlock that stops lamps when opened.
- Mechanical or digital timer with 1 to 60 minute range.
- Optional quartz shelves and tray for full irradiance.
- Wall-mount or bench-top configurations.
What are the technical specifications?
A typical uv sterilization cabinet configuration offers chamber volume of 50-500 L, lamp type of Low-pressure mercury, 253.7 nm, lamp power of 8-40 W per lamp, number of lamps of 1-4, timer range of 1-60 min and typical surface dose of 30-100 mJ/cm² per cycle. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The UV Sterilization Cabinet is used in small instrument disinfection, reusable mask and goggle disinfection, glassware and tube surface treatment and media preparation bench support. Across the wider UV Sterilizers class, laboratories also deploy it for disinfection of work surfaces and small instruments, air disinfection in laboratories and animal rooms and feed water and rinse water disinfection.
Which standards and certifications apply?
Relevant standards and methods include IEC 62471, IEC 61010-1, GB 19258, ISO 15858, ASTM E3135 and ISO 9001 manufacturing. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 62471 photobiological safety report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
UV is a surface method, so clean items before irradiation and do not expect penetration into lumens, joints or packaging. Protect eyes and skin: run lamps only in closed cabinets or with interlocked rooms, and post warning signs. Fluence should be checked with a calibrated radiometer at installation and then at fixed intervals, since lamp output falls long before the lamp fails to light. Clean quartz sleeves and lamp tubes with alcohol to remove dust films that reduce output. Replace lamps at the rated hours or when measured output falls below about 70 percent. Consider 185 nm ozone-generating lamps only in ventilated, unoccupied spaces, and never use UV as a replacement for validated heat sterilization.
How do I select the right UV Sterilization Cabinet?
Select the cabinet when items are small, dry and have exposed surfaces, and when heat or moisture would damage them. Check internal volume against the largest tray you will use, confirm that shelves do not shade the load, and compare lamp power and count with the cycle time you need. Specify lamp type, interlock, timer range and whether quartz shelves are supplied.
How does it compare with other UV Sterilizers variants?
Start with the target: surfaces, air or water, because each needs a different enclosure and dose. For cabinets, compare internal volume with the items to be treated and check that lamps reach every corner, since shadows limit efficacy. For air sterilizers, look at airflow in m³/h and the rated lamp power, as these together set the residence time and dose. For water units, check flow rate, lamp count and sleeve material. Confirm lamp type (253.7 nm germicidal or 254 nm amalgam), rated life in hours, quartz versus borosilicate sleeves, door interlocks and timer range. Where sporicidal or validated disinfection is required, ask for dose verification data rather than relying on nominal lamp power.
Full specifications
| Chamber volume | 50-500 L |
|---|---|
| Lamp type | Low-pressure mercury, 253.7 nm |
| Lamp power | 8-40 W per lamp |
| Number of lamps | 1-4 |
| Timer range | 1-60 min |
| Typical surface dose | 30-100 mJ/cm² per cycle |
| Rated lamp life | 6,000-9,000 h |
| Interior material | Reflective SUS304 stainless steel |
| Safety features | Door interlock, UV-blocking viewing window |
| Power supply | 220 V, 50 Hz, 30-200 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Small instrument disinfection
- Reusable mask and goggle disinfection
- Glassware and tube surface treatment
- Media preparation bench support
Key features
- Light-tight stainless cabinet of 50 to 500 L with reflective interior.
- One to four 253.7 nm lamps of 8 to 40 W.
- Door switch or interlock that stops lamps when opened.
- Mechanical or digital timer with 1 to 60 minute range.
- Optional quartz shelves and tray for full irradiance.
- Wall-mount or bench-top configurations.
Frequently asked questions about UV Sterilization Cabinet
Dry items with exposed surfaces, such as forceps, scissors, goggles, masks, keyboards, small parts and clean glassware. Wrapped, bagged or liquid items are unsuitable because UV-C does not penetrate packaging or liquid films.
UV-C travels in straight lines, so anything under a shelf or behind a solid object receives little light. Use wire or quartz shelves and leave space around items so that every surface faces a lamp.
No. It disinfects exposed surfaces only and does not sterilize wrapped loads, liquids, media or items with lumens and joints. Use it for surface disinfection and keep validated heat or chemical sterilization for critical items.
Exposure time depends on the required dose and the lamp irradiance at the surface. Typical cabinet cycles run 15 to 30 minutes, surface lamps 30 to 60 minutes, and air sterilizers work continuously. Measure irradiance at the target surface rather than assuming a fixed time.
Ordinary window glass blocks most UV-C, and most plastics absorb it as well. Items must be directly exposed, so wrapped, covered or bagged goods and closed containers are not disinfected by UV.
Only with controls. Direct UV-C exposure harms eyes and skin, so lamps belong in interlocked cabinets or closed rooms, warning signs are required, and personal protective equipment should include UV-blocking eyewear. Measure stray radiation where staff work.