Steam-Air Mixture Sterilizer for Sealed Liquid Loads
密封液体负载蒸汽-空气混合灭菌器
- SKU STS-0002
- Steam Sterilizers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- PED 2014/68/EU pressure vessel documentation (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Working temperature | 105-121 °C |
|---|---|
| Chamber volume | 150-2,000 L |
| Counter-pressure range | 0-0.25 MPa above steam pressure |
| Temperature uniformity | ±1-2 °C with air mixing |
| Typical hold time | 15-40 min |
| Air supply | Filtered, 0.4-0.6 MPa, oil-free |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 285, EN 13060, ISO 17665-1
What is the Steam-Air Mixture Sterilizer for Sealed Liquid Loads?
A sterilizer that mixes compressed air with steam and applies counter-pressure to sterilize sealed bottles, bags and ampoules without bursting them. It controls heating and cooling ramps so liquid loads stay intact.
What is the Steam-Air Mixture Sterilizer for Sealed Liquid Loads?
A sterilizer that mixes compressed air with steam and applies counter-pressure to sterilize sealed bottles, bags and ampoules without bursting them. It controls heating and cooling ramps so liquid loads stay intact.
Overview
The steam-air mixture sterilizer adds filtered compressed air to the chamber so that total pressure can exceed the saturated steam pressure at the set temperature. That external pressure balances the rising internal pressure of a sealed container, preventing deformation or bursting, and is why the method is used for glass bottles, plastic bags, ampoules, vials and sealed process vessels. Temperature is limited to about 121 °C to protect heat-sensitive solutions. Air is mixed with steam by a fan or an air injection ring, so temperature uniformity depends on good mixing and is usually ±1 to 2 °C. Cycles have programmable heat-up ramps, a hold period of 15 to 40 minutes and slow cooling, all under pressure control. A water-ring pump or ejector removes air and steam at cycle end, and pressure is released gradually to protect the load.
How does it work?
Steam sterilization relies on saturated steam condensing on the load, where it releases latent heat and raises the surface temperature rapidly; the moisture plus heat coagulates proteins and kills microorganisms, including spores. Cycle efficacy depends on air removal, because trapped air forms a cooler pocket that blocks steam contact. Machines therefore use gravity displacement, where steam enters at the top and pushes air out of a bottom drain, or pre-vacuum cycles, where a pump or ejector removes air in stages before steam admission. Saturated steam quality is defined by dryness fraction, non-condensable gases and superheat. A jacketed chamber and insulated door hold temperature, a pressure vessel with a safety valve contains the load, and instruments record chamber pressure and load temperature so the cycle can be documented and validated.
What are the key features?
- Compressed air injection for counter-pressure control.
- Balance of internal container pressure to prevent bursting.
- Programmable heat-up and cooling ramps for liquid loads.
- Uniformity of ±1 to 2 °C with fan-assisted air mixing.
- Pressure-controlled venting at cycle end.
- Suitable for bottles, bags, ampoules and sealed vessels.
What are the technical specifications?
A typical steam-air mixture sterilizer for sealed liquid loads configuration offers working temperature of 105-121 °C, chamber volume of 150-2,000 L, counter-pressure range of 0-0.25 MPa above steam pressure, temperature uniformity of ±1-2 °C with air mixing, typical hold time of 15-40 min and air supply of Filtered, 0.4-0.6 MPa, oil-free. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Steam-Air Mixture Sterilizer for Sealed Liquid Loads is used in sealed bottled solutions and buffers, ampoule and vial sterilization, media and reagent bags and sterilization of sealed process vessels. Across the wider Steam Sterilizers class, laboratories also deploy it for sterile processing of instruments and glassware, pharmaceutical media and buffer sterilization and sealed liquid loads in bottles and ampoules.
Which standards and certifications apply?
Relevant standards and methods include EN 285, EN 13060, ISO 17665-1, ISO 11140-1, EN ISO 11138-1, HTM 01-01 and ISO 13485 manufacturing. Certification candidates for this model are CE, ISO 13485 manufacturing and PED 2014/68/EU pressure vessel documentation; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the sterilizer on a level floor near a drain, with clearance for door swing and service access, and confirm the electrical supply suits the installed power, which can reach 40 kW for generator-equipped models. Verify steam supply pressure, dryness and absence of non-condensable gases before commissioning, since poor steam quality causes failed cycles. Validate with thermocouples in the load and with biological indicators such as Geobacillus stearothermophilus spores. Perform daily warm-up and air-removal checks, weekly steam quality and safety-valve checks, and annual calibration of temperature and pressure instruments. Maintain door gaskets, steam traps, filters and vacuum pumps on schedule, and keep records for the pressure-vessel inspection interval required locally.
How do I select the right Steam-Air Mixture Sterilizer for Sealed Liquid Loads?
Select the steam-air mixture machine whenever sealed containers hold liquid and bursting or deformation is a risk. Check the maximum counter-pressure and whether the controller supports the ramps your product needs, as cooling rate often limits cycle time. Specify chamber size, air supply quality, cooling method, load sensor positions and the documentation required for cycle validation.
How does it compare with other Steam Sterilizers variants?
Begin with the load: wrapped instruments need pre-vacuum cycles, sealed liquid bottles need steam-air mixtures with counter-pressure, and process lines need continuous or in-situ sterilization. Then choose the steam source. House steam is economical but depends on plant supply quality and availability, while an integrated electric generator gives independence at higher running cost and electrical demand. Match chamber volume to the largest load and allow 20 to 30 percent free space for steam circulation. Check the achievable cycle range, temperature uniformity, control and recording system, door type, vacuum capability and the documentation needed for validation. Confirm local pressure-vessel rules and the permissible steam supply pressure before ordering.
Full specifications
| Working temperature | 105-121 °C |
|---|---|
| Chamber volume | 150-2,000 L |
| Counter-pressure range | 0-0.25 MPa above steam pressure |
| Temperature uniformity | ±1-2 °C with air mixing |
| Typical hold time | 15-40 min |
| Air supply | Filtered, 0.4-0.6 MPa, oil-free |
| Cooling method | Controlled pressure venting or cooling coil |
| Chamber material | SUS316L stainless steel |
| Controls | PLC with ramp programming and cycle records |
| Door type | Slide or swing door with safety interlock |
| Power supply | 380 V, 50 Hz, 3 phase |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Sealed bottled solutions and buffers
- Ampoule and vial sterilization
- Media and reagent bags
- Sterilization of sealed process vessels
Key features
- Compressed air injection for counter-pressure control.
- Balance of internal container pressure to prevent bursting.
- Programmable heat-up and cooling ramps for liquid loads.
- Uniformity of ±1 to 2 °C with fan-assisted air mixing.
- Pressure-controlled venting at cycle end.
- Suitable for bottles, bags, ampoules and sealed vessels.
Frequently asked questions about Steam-Air Mixture Sterilizer for Sealed Liquid Loads
A sealed container heated by steam develops internal pressure that can exceed the chamber pressure and burst the glass or distort the plastic. Adding compressed air raises chamber pressure to match, so the container is supported from outside.
Yes, if ramps and counter-pressure are set for that container. Slow heating and cooling, with a hold at 121 °C, keeps thermal stress low. Validate with the actual bottle, fill volume and closure before routine use.
Fast venting would flash-boil the liquid and could rupture containers, so pressure is released in steps while the load cools. Cooling often takes as long as heating, which is why total cycle times reach one to two hours.
Both use saturated steam, but 134 °C is about 2.1 bar gauge and sterilizes in 3 to 4 minutes, while 121 °C at about 1.1 bar gauge needs 15 to 20 minutes. Higher temperature suits wrapped instrument loads and faster turnaround; lower temperature suits heat-sensitive media and liquids.
Air does not sterilize and collects in cooler pockets that prevent steam contact with the load. Pre-vacuum cycles remove it with a pump before steam enters, and gravity cycles rely on steam pushing air out of a bottom drain.
Validation uses temperature probes placed in the load, air-removal tests, and biological indicators with Geobacillus stearothermophilus spores. Acceptance requires that the coldest point reaches the set temperature for the full hold time and that indicators show no growth.