Key specifications

Key specifications
Number of lamps1-4
Total lamp power30-120 W
Effective distance1-3 m
Typical cycle time15-60 min
Timer start delay30-60 s
Height adjustment0.9-1.8 m
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 62471, IEC 61010-1, GB 19258

What is the Mobile UV Sterilization Lamp Cart?

A wheeled stand carrying one to four shielded UV-C tubes and a timer, used to irradiate empty rooms, work surfaces and equipment directly. It suits terminal disinfection of areas that can be vacated for the cycle.

What is the Mobile UV Sterilization Lamp Cart?

A wheeled stand carrying one to four shielded UV-C tubes and a timer, used to irradiate empty rooms, work surfaces and equipment directly. It suits terminal disinfection of areas that can be vacated for the cycle.

Overview

The mobile UV cart mounts upright UV-C tubes on a tubular frame with lockable castors, so a single unit can treat several rooms. A timer, often remote-controlled, switches the lamps and allows staff to leave before irradiation begins, and a delay of 30 to 60 seconds is common. Lamps are effective at distances of 1 to 3 m, with irradiance falling as the square of distance, so the cart is moved to several positions or the tubes are arranged radially for 360-degree coverage. Tube power is typically 30 to 120 W in total, and a cycle of 15 to 60 minutes delivers a surface dose that depends on distance and angle. Removable reflectors, height adjustment and an indicator beacon or door sensor are common options. The method disinfects only what the light reaches.

How does it work?

Ultraviolet sterilization uses UV-C light, emitted mainly at 253.7 nm by low-pressure mercury lamps, which nucleic acids absorb so that pyrimidine dimers form and block replication. Efficacy depends on dose, the product of irradiance in µW/cm² and exposure time in seconds, expressed in mJ/cm². Germicidal cabinets place items on a reflective stainless steel tray below one or more lamps and run a timed cycle of 5 to 60 minutes. Air sterilizers draw room air through a chamber with lamps and baffles so the moving air receives the required dose while people remain outside the direct beam. Water units pass the flow around quartz-sleeved lamps. Because UV light travels in straight lines, only surfaces in direct view are treated, so shadowed, covered or dusty areas are not disinfected.

What are the key features?

  • One to four upright UV-C tubes on a lockable castor frame.
  • Remote-controlled timer with start delay for safe egress.
  • Radial tube layout option for 360-degree coverage.
  • Adjustable height and removable reflectors.
  • Warning beacon and door sensor options.
  • Moves between rooms for terminal disinfection.

What are the technical specifications?

A typical mobile uv sterilization lamp cart configuration offers number of lamps of 1-4, total lamp power of 30-120 W, effective distance of 1-3 m, typical cycle time of 15-60 min, timer start delay of 30-60 s and height adjustment of 0.9-1.8 m. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Mobile UV Sterilization Lamp Cart is used in terminal disinfection of laboratory rooms, animal facility room disinfection, cleanroom and changing room treatment and emergency spill area disinfection. Across the wider UV Sterilizers class, laboratories also deploy it for disinfection of work surfaces and small instruments, air disinfection in laboratories and animal rooms and feed water and rinse water disinfection.

Which standards and certifications apply?

Relevant standards and methods include IEC 62471, IEC 61010-1, GB 19258, ISO 15858, ASTM E3135 and ISO 9001 manufacturing. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 62471 photobiological safety report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

UV is a surface method, so clean items before irradiation and do not expect penetration into lumens, joints or packaging. Protect eyes and skin: run lamps only in closed cabinets or with interlocked rooms, and post warning signs. Fluence should be checked with a calibrated radiometer at installation and then at fixed intervals, since lamp output falls long before the lamp fails to light. Clean quartz sleeves and lamp tubes with alcohol to remove dust films that reduce output. Replace lamps at the rated hours or when measured output falls below about 70 percent. Consider 185 nm ozone-generating lamps only in ventilated, unoccupied spaces, and never use UV as a replacement for validated heat sterilization.

How do I select the right Mobile UV Sterilization Lamp Cart?

Select the cart when rooms can be vacated and surfaces are exposed, as for terminal disinfection or spill response. Compare total lamp power, tube layout and whether the room needs one position or several. Confirm that a delay timer, warning beacon and door sensor are fitted, and specify the surface dose you expect at the furthest point of the room.

How does it compare with other UV Sterilizers variants?

Start with the target: surfaces, air or water, because each needs a different enclosure and dose. For cabinets, compare internal volume with the items to be treated and check that lamps reach every corner, since shadows limit efficacy. For air sterilizers, look at airflow in m³/h and the rated lamp power, as these together set the residence time and dose. For water units, check flow rate, lamp count and sleeve material. Confirm lamp type (253.7 nm germicidal or 254 nm amalgam), rated life in hours, quartz versus borosilicate sleeves, door interlocks and timer range. Where sporicidal or validated disinfection is required, ask for dose verification data rather than relying on nominal lamp power.

Full specifications

Full specifications
Number of lamps1-4
Total lamp power30-120 W
Effective distance1-3 m
Typical cycle time15-60 min
Timer start delay30-60 s
Height adjustment0.9-1.8 m
ControlRemote control with audible warning
Rated lamp life6,000-9,000 h
MobilityLockable castors, tubular steel frame
Power supply220 V, 50 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Terminal disinfection of laboratory rooms
  • Animal facility room disinfection
  • Cleanroom and changing room treatment
  • Emergency spill area disinfection

Key features

  • One to four upright UV-C tubes on a lockable castor frame.
  • Remote-controlled timer with start delay for safe egress.
  • Radial tube layout option for 360-degree coverage.
  • Adjustable height and removable reflectors.
  • Warning beacon and door sensor options.
  • Moves between rooms for terminal disinfection.

Frequently asked questions about Mobile UV Sterilization Lamp Cart

One central position often covers a small room, but larger rooms and furniture create shadows that need extra positions or a second cycle. Plan the route and check for shaded surfaces with a radiometer during validation.

Related models

All UV Sterilizers
UV Air Sterilizer — product photo

UV Air Sterilizer

紫外线空气消毒机

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the Mobile UV Sterilization Lamp Cart

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote