Benchtop Glass Bead Sterilizer
台式玻璃珠灭菌器
- SKU GBS-0001
- Glass Bead Sterilizers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- EN 61010-1 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Working temperature | 250 °C nominal |
|---|---|
| Temperature control | Bimetallic or PID thermostat |
| Warm-up time to 250 °C | 20-30 min |
| Well diameter | 40-60 mm |
| Well depth | 40-80 mm |
| Glass bead size | 1.5-4 mm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 61010-1, EN 61010-2-010, ISO 11138-1
What is the Benchtop Glass Bead Sterilizer?
A single-well benchtop unit that heats glass beads to 250 °C for rapid surface sterilization of small metal instruments. It is the standard choice for busy microbiology and animal research benches that re-use forceps and loops between steps.
What is the Benchtop Glass Bead Sterilizer?
A single-well benchtop unit that heats glass beads to 250 °C for rapid surface sterilization of small metal instruments. It is the standard choice for busy microbiology and animal research benches that re-use forceps and loops between steps.
Overview
The benchtop glass bead sterilizer consists of a stainless steel well, a resistive heating element wrapped around or beneath the well, mineral insulation and an outer metal case. The well holds about 100 to 200 g of glass beads, typically 1.5 to 4 mm in diameter, and reaches 250 °C in 20 to 30 minutes from cold. A bimetallic or PID thermostat holds the temperature, and a front-panel lamp or digital display shows the ready state. Most units operate from 220 V single-phase power at 100 to 300 W and have an on-off switch with a thermal fuse. Wells are usually 40 to 60 mm wide and 40 to 80 mm deep, which suits forceps, scissors, loops, needles and small blades. A metal basket or a removable bead tray simplifies emptying and cleaning.
How does it work?
Glass bead sterilization works by thermal conduction. A well in the unit holds soda-lime or borosilicate beads of about 1.5 to 4 mm diameter, and a resistive heating element raises them to the set temperature, commonly 250 °C. The bead bed has a high thermal mass, so when a small instrument is pushed into it the beads transfer heat directly to the metal and surface microorganisms are killed by dry heat within 10 to 30 seconds. A thermocouple or platinum sensor in the well feeds a controller that switches the heater and holds the temperature, while a timer or indicator lamp shows when the unit is ready. Insulation around the well limits heat loss and keeps the outer case cool. Because heat reaches only the surfaces touching the beads, deep lumens and hinges may stay unsterilized.
What are the key features?
- Single stainless steel well holding 100 to 200 g of 1.5 to 4 mm beads.
- Reaches 250 °C in 20 to 30 minutes from ambient.
- Indicator lamp or digital display shows when the bed is ready.
- Thermal fuse and insulated case for bench safety.
- Removable bead tray or basket for cleaning and replacement.
- Compact footprint under 0.05 m² for crowded benches.
What are the technical specifications?
A typical benchtop glass bead sterilizer configuration offers working temperature of 250 °C nominal, temperature control of Bimetallic or PID thermostat, warm-up time to 250 °C of 20-30 min, well diameter of 40-60 mm, well depth of 40-80 mm and glass bead size of 1.5-4 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Glass Bead Sterilizer is used in forceps and scissors sterilization at the bench, inoculating loop and needle sterilization, animal surgery instrument touch-up and microbiology teaching laboratories. Across the wider Glass Bead Sterilizers class, laboratories also deploy it for rapid sterilization of forceps and scissors, inoculating loop and needle sterilization and animal research instrument sterilization.
Which standards and certifications apply?
Relevant standards and methods include EN 61010-1, EN 61010-2-010, ISO 11138-1, GB 4793.1 and ISO 9001 manufacturing. Certification candidates for this model are CE, ISO 9001 manufacturing and EN 61010-1 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the unit on a heat-resistant bench away from flammable materials and leave at least 10 cm clearance on all sides. Use a dedicated socket, since benchtop units typically draw 100 to 300 W. Verify the bed temperature with an external thermometer at installation and annually afterwards, because a drifting thermostat can leave the bed below the effective temperature. Keep the bed filled to the marked level, as low beads reduce contact and overheat the element. Remove debris and metal chips with a sieve, and replace beads when they discolor, crack or sinter. Wear heat-resistant gloves when inserting instruments and never place solvent bottles near the well.
How do I select the right Benchtop Glass Bead Sterilizer?
Select this variant for general bench use where 250 °C and warm-up of about 30 minutes are acceptable. If staff work continuously, two units or a double-well model keeps one bed hot while the other recovers. Specify the well diameter and depth needed for your longest instrument, the bead size, and whether a digital display or timer is required.
How does it compare with other Glass Bead Sterilizers variants?
Choose a glass bead sterilizer when small metal tools must be re-used quickly between bench steps, not when packaged loads, liquids or lumens need sterilization. Compare the well diameter and depth with the length of your instruments, because long forceps must reach the bead bed without the handle becoming too hot. Check the maximum temperature, the warm-up time and the recovery time after each insertion. A digital temperature display and timer make routine use more consistent than a simple indicator lamp. For heavy use, two wells or two units avoid waiting during warm-up. Confirm the bead size, the availability of replacement bead packs and whether a basket or heat shield is included.
Full specifications
| Working temperature | 250 °C nominal |
|---|---|
| Temperature control | Bimetallic or PID thermostat |
| Warm-up time to 250 °C | 20-30 min |
| Well diameter | 40-60 mm |
| Well depth | 40-80 mm |
| Glass bead size | 1.5-4 mm |
| Bead capacity | 100-200 g |
| Typical hold time | 10-30 s per instrument |
| Power supply | 220 V, 50 Hz, 100-300 W |
| Housing material | Powder-coated steel, stainless well |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Forceps and scissors sterilization at the bench
- Inoculating loop and needle sterilization
- Animal surgery instrument touch-up
- Microbiology teaching laboratories
Key features
- Single stainless steel well holding 100 to 200 g of 1.5 to 4 mm beads.
- Reaches 250 °C in 20 to 30 minutes from ambient.
- Indicator lamp or digital display shows when the bed is ready.
- Thermal fuse and insulated case for bench safety.
- Removable bead tray or basket for cleaning and replacement.
- Compact footprint under 0.05 m² for crowded benches.
Frequently asked questions about Benchtop Glass Bead Sterilizer
One or two small instruments fit comfortably in a 40 to 60 mm well. Loading more than that lowers the bed temperature and slows recovery, so insert items one at a time and wait for the display to return to 250 °C.
It helps when cycles must be repeatable or recorded. Staff can see the actual temperature, recovery after each insertion and any drift, which a simple ready lamp cannot show. Indicator lamps remain acceptable for routine teaching laboratories.
Place it on a heat-resistant bench within arm's reach of the work area, away from solvents and plastics, with at least 10 cm of clearance around the case for ventilation.
Small instruments are held in the heated beads for about 10 to 30 seconds at 250 °C. Thin items such as loops and needles need the shorter time, while hinged forceps and scissors may need 20 to 30 seconds. Between insertions, allow the bed to recover to the set temperature.
Typical units hold 250 °C, and high-temperature versions reach 300 °C or more. Hold times of 10 to 30 seconds are used for small metal instruments. Confirm the actual bed temperature with an external probe, because displayed values can drift over time.
No. The method depends on direct contact between hot beads and metal surfaces. Liquids would boil or spill, and plastics soften or melt. Use an autoclave for liquids, media and wrapped goods, and keep bead sterilizers for small metal items only.
Related models