Benchtop Mini Dry Heat Sterilizer for Small Instruments
小型台式干热灭菌器(小器械用)
- SKU DHS-0005
- Dry Heat Sterilizers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | Ambient +10 to 200 °C |
|---|---|
| Chamber volume | 5-20 L |
| Temperature uniformity | ±5-8 °C at 170 °C |
| Heat-up time to 170 °C | 15-30 min |
| Air circulation | Natural or small fan |
| Chamber material | Stainless steel |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1211>, Ph. Eur. 5.1.1, USP <1228.1> Dry heat depyrogenation
What is the Benchtop Mini Dry Heat Sterilizer for Small Instruments?
A small benchtop dry heat sterilizer of 5 to 20 L that reaches 160 to 200 °C. It serves dental, veterinary and small laboratory users who sterilize a few metal instruments or glass items at a time without a steam supply.
What is the Benchtop Mini Dry Heat Sterilizer for Small Instruments?
A small benchtop dry heat sterilizer of 5 to 20 L that reaches 160 to 200 °C. It serves dental, veterinary and small laboratory users who sterilize a few metal instruments or glass items at a time without a steam supply.
Overview
The benchtop mini sterilizer is a compact hot-air unit with a chamber of 5 to 20 L that stands on a counter. It heats to 160 to 200 °C with a small element and optional fan, and a timer with an audible alarm signals the end of the cycle. Weight is typically 8 to 25 kg. Because the load is small, heat-up takes 15 to 30 minutes and total cycle times are 1 to 3 hours. It suits dental burs, small forceps, scissors and metal tools that tolerate dry heat and do not need wrapping, and it avoids the water and drainage needs of autoclaves. Uniformity is less tightly controlled than in full-size ovens, so loads should be small and arranged in a single layer. Operators should verify cycles with chemical or biological indicators.
How does it work?
Dry heat sterilization kills microorganisms by oxidation and protein denaturation in the absence of moisture. Because air conducts heat less efficiently than steam, higher temperatures and longer times are needed, for example 160 °C for 120 minutes, 170 °C for 60 minutes or 180 °C for 30 minutes. A heated chamber uses electric heating elements, and either natural gravity convection or a fan circulates air to equalize temperature. Fan-forced models reduce gradients and speed heat-up. A controller reads a platinum resistance or thermocouple sensor, and an independent overtemperature cut-out protects the unit. Timing begins when the coldest point in the load reaches the set temperature. Depyrogenation ovens run at 250 to 350 °C to destroy endotoxin, often with HEPA-filtered air supply. Insulated walls and a sealed door limit heat loss.
What are the key features?
- Compact chamber of 5 to 20 L sits on a standard counter.
- Reaches 160 to 200 °C with heat-up in 15 to 30 minutes.
- No water or drain connection required.
- Timer with audible end-of-cycle alarm.
- Overtemperature cut-out for safe operation.
- Light weight of 8 to 25 kg for easy relocation.
What are the technical specifications?
A typical benchtop mini dry heat sterilizer for small instruments configuration offers temperature range of Ambient +10 to 200 °C, chamber volume of 5-20 L, temperature uniformity of ±5-8 °C at 170 °C, heat-up time to 170 °C of 15-30 min, air circulation of Natural or small fan and chamber material of Stainless steel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Mini Dry Heat Sterilizer for Small Instruments is used in dental burs and small tools, veterinary clinic instruments, small glass items and field and teaching use. Across the wider Dry Heat Sterilizers class, laboratories also deploy it for glassware sterilization, metal instrument sterilization and depyrogenation of vials and glassware.
Which standards and certifications apply?
Relevant standards and methods include USP <1211>, Ph. Eur. 5.1.1, USP <1228.1> Dry heat depyrogenation, ISO 20857, EN 61010-2-010, GB/T 30690 and EN 13060. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the sterilizer on a non-combustible surface with clearance for ventilation and keep flammable materials away. Use a dedicated electrical circuit sized for the heater. Load items in racks so air can circulate, and do not overfill. Wrap or cover items with aluminum foil or place them in metal or borosilicate containers that tolerate the temperature. Start timing at the set temperature for the coldest point, which is verified with thermocouples during validation. Use chemical indicators or biological indicators such as Bacillus atrophaeus spores to verify cycles. Allow the load to cool before opening, since glass can crack with thermal shock. Calibrate the temperature sensor annually and check door seals and fans regularly. Follow burn-safety rules when unloading.
How do I select the right Benchtop Mini Dry Heat Sterilizer for Small Instruments?
Select the mini sterilizer for a few small metal instruments and no steam supply. Choose a forced-air oven for racks of glassware or regulated work. Specify chamber size, maximum temperature, timer features and whether a fan is needed.
How does it compare with other Dry Heat Sterilizers variants?
Decide first whether you need sterilization, which runs at 160 to 180 °C, or depyrogenation, which needs 250 °C or above. Then choose between gravity convection, which is simple and gentle on powders, and forced-air models, which give tighter uniformity and faster cycles. Size the chamber for the largest racks or trays and allow space between items for airflow. Check temperature range, uniformity across the chamber, programmable cycles and cooling rate. Regulated laboratories need data logging, validated load mapping and, for pharmaceutical use, HEPA filtration and double-door configurations. Confirm that the materials to be processed tolerate the temperature. Plastics, rubber, liquids, and most textiles are unsuitable, and sharp instruments may lose temper at higher temperatures.
Full specifications
| Temperature range | Ambient +10 to 200 °C |
|---|---|
| Chamber volume | 5-20 L |
| Temperature uniformity | ±5-8 °C at 170 °C |
| Heat-up time to 170 °C | 15-30 min |
| Air circulation | Natural or small fan |
| Chamber material | Stainless steel |
| Timer range | 0-999 min |
| Unit weight | 8-25 kg |
| Safety devices | Overtemperature cut-out, door switch |
| Power supply | 220 V, 50 Hz, 0.3-1.2 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Dental burs and small tools
- Veterinary clinic instruments
- Small glass items
- Field and teaching use
Key features
- Compact chamber of 5 to 20 L sits on a standard counter.
- Reaches 160 to 200 °C with heat-up in 15 to 30 minutes.
- No water or drain connection required.
- Timer with audible end-of-cycle alarm.
- Overtemperature cut-out for safe operation.
- Light weight of 8 to 25 kg for easy relocation.
Frequently asked questions about Benchtop Mini Dry Heat Sterilizer for Small Instruments
Heat-stable metal instruments and small glass items that can be placed unwrapped or in metal trays. It is not suitable for plastics, rubber, liquids or textiles.
Use chemical indicators on each load and periodic biological indicators with Bacillus atrophaeus spores. Record temperature and time for each cycle.
Small chambers can show larger gradients because of limited airflow and thermal mass, so keep loads small, in a single layer and away from chamber walls.
Common cycles are 160 °C for 120 minutes, 170 °C for 60 minutes or 180 °C for 30 minutes, with timing starting when the coldest point reaches the set temperature. Validate parameters for your load.
Sterilization kills viable microorganisms at about 160 to 180 °C. Depyrogenation destroys bacterial endotoxin and needs about 250 °C or higher, since endotoxin is far more heat-resistant than spores.
Glassware, metal instruments, ceramics, powders and oils can be processed. Plastics, rubber, liquids in sealed containers, paper and most textiles are unsuitable because they melt, burn or degrade.