Top-Loading Vertical Pressure Steam Autoclave

顶装立式压力蒸汽高压灭菌器

  • SKU AUT-0001
  • Autoclaves
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • Pressure vessel registration certificate (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Chamber volume18-150 L
Sterilization temperature105-134 °C
Working pressureUp to 0.22 MPa
Air removalGravity displacement
Chamber materialSUS304 stainless steel
Heating power2-9 kW
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 13060, EN 285, ISO 17665-1

What is the Top-Loading Vertical Pressure Steam Autoclave?

A vertical autoclave with a top-opening lid and a cylindrical chamber of 18 to 150 L. It is an economical gravity-displacement sterilizer for media, glassware, liquids and waste in teaching, research and small clinical laboratories.

What is the Top-Loading Vertical Pressure Steam Autoclave?

A vertical autoclave with a top-opening lid and a cylindrical chamber of 18 to 150 L. It is an economical gravity-displacement sterilizer for media, glassware, liquids and waste in teaching, research and small clinical laboratories.

Overview

The vertical autoclave is the classic laboratory steam sterilizer. A stainless steel cylindrical chamber is loaded from above, and a hinged or bolted lid with a silicone gasket closes against the chamber rim. Steam is produced by an electric heater at the base or by an internal generator, and air is expelled through a manual or automatic vent. Typical working temperatures are 121 and 134 °C at up to 0.22 MPa. Capacities of 18 to 150 L are common, and modern units have microprocessor controls with programmable times, automatic exhaust, water-level protection and overpressure valves. Liquids can be processed with slow exhaust. Because the chamber is deep and the footprint small, the format is economical, but loading heavy baskets requires lifting. Gravity air removal limits use with wrapped or hollow instruments.

How does it work?

An autoclave sterilizes by exposing items to saturated steam under pressure. At 103 kPa gauge, steam reaches 121 °C, and at about 205 kPa it reaches 134 °C. Steam condenses on cooler surfaces, releasing latent heat that denatures proteins and destroys microorganisms far faster than dry heat at the same temperature. A cycle has three main phases: air removal, sterilization hold and exhaust or drying. Gravity-displacement units push air out through a drain by steam flow, while pre-vacuum units use a vacuum pump to remove air before steam admission, which penetrates porous loads and hollow instruments. A steam generator or jacket supplies steam, a controller reads temperature and pressure sensors, and safety valves, door interlocks and overpressure devices protect users. Validated hold times typically range from 3 to 30 minutes depending on load and temperature.

What are the key features?

  • Stainless steel cylindrical chamber loaded from above with basket or rack.
  • Microprocessor control with programmable temperature and hold time.
  • Automatic exhaust and slow-exhaust option for liquids.
  • Low-water protection and overpressure safety valve.
  • Lid interlock prevents opening while chamber is pressurized.
  • Optional printer or USB record of cycle data.

What are the technical specifications?

A typical top-loading vertical pressure steam autoclave configuration offers chamber volume of 18-150 L, sterilization temperature of 105-134 °C, working pressure of Up to 0.22 MPa, air removal of Gravity displacement, chamber material of SUS304 stainless steel and heating power of 2-9 kW. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Top-Loading Vertical Pressure Steam Autoclave is used in culture media sterilization, glassware and pipette tip sterilization, laboratory waste decontamination and teaching laboratory use. Across the wider Autoclaves class, laboratories also deploy it for microbiology media sterilization, laboratory waste decontamination and glassware and instrument sterilization.

Which standards and certifications apply?

Relevant standards and methods include EN 13060, EN 285, ISO 17665-1, ISO 11138, ASME BPVC Section VIII, GB 8599 and EN 61010-2-040. Certification candidates for this model are CE, ISO 9001 manufacturing and Pressure vessel registration certificate; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the autoclave on a level floor with clearances specified by the maker for service and ventilation, and provide a drain, water supply and electrical circuit sized to the heater. Use distilled, deionized or conditioned water as specified to limit scale. Pressure vessels are regulated in most countries, so arrange registration, periodic inspection and operator training. Qualify the unit with installation and operational checks, then validate each load type using thermocouples and biological indicators such as Geobacillus stearothermophilus spores. Perform Bowie-Dick or helix tests daily on vacuum models. Inspect door seals, gaskets and safety valves regularly, descale the chamber and steam generator, and calibrate sensors annually. Never autoclave sealed containers, solvents or bleach-containing waste.

How do I select the right Top-Loading Vertical Pressure Steam Autoclave?

Select the vertical autoclave for general media, glassware, liquids and waste when budget and footprint matter. Horizontal or vacuum models are better for wrapped instruments. Specify chamber volume, steam source, control features, data output, pressure code and loading method in the RFQ.

How does it compare with other Autoclaves variants?

Match the autoclave to the load and the level of assurance required. Liquids, glassware and waste can be processed in gravity cycles, while wrapped instruments, porous textiles and hollow devices need pre-vacuum to remove air. Select chamber volume from the largest load and throughput, typically 18 L for small benchtop units to 1000 L or more for floor-standing models. Decide between top-loading vertical units for economy, front-loading horizontal units for ergonomics, and double-door pass-through units to separate clean and contaminated zones. Check cycle options, such as liquid, waste and dry cycles, printer or data logging, and validation support. Confirm the pressure vessel code, steam source and water quality, and compare electrical or steam supply requirements and installation space, including door swing and drainage.

Full specifications

Full specifications
Chamber volume18-150 L
Sterilization temperature105-134 °C
Working pressureUp to 0.22 MPa
Air removalGravity displacement
Chamber materialSUS304 stainless steel
Heating power2-9 kW
Timer range0-99 min
Temperature control accuracy±1 °C
Safety devicesSafety valve, lid interlock, low-water protection
Power supply220 V / 380 V, 50 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Culture media sterilization
  • Glassware and pipette tip sterilization
  • Laboratory waste decontamination
  • Teaching laboratory use

Key features

  • Stainless steel cylindrical chamber loaded from above with basket or rack.
  • Microprocessor control with programmable temperature and hold time.
  • Automatic exhaust and slow-exhaust option for liquids.
  • Low-water protection and overpressure safety valve.
  • Lid interlock prevents opening while chamber is pressurized.
  • Optional printer or USB record of cycle data.

Frequently asked questions about Top-Loading Vertical Pressure Steam Autoclave

Only with limits. Gravity air removal may leave air pockets in wrapped or hollow loads, so use it for unwrapped solids, liquids and glassware, or validate the cycle carefully for packs.