Front-Loading Horizontal Rectangular Autoclave

前装卧式矩形高压灭菌器

  • SKU AUT-0003
  • Autoclaves
  • CE (to be confirmed)
  • PED 2014/68/EU (to be confirmed)
  • ASME U-stamp (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Chamber volume100-1000 L
Chamber dimensions (example 300 L)About 600 × 600 × 830 mm
Sterilization temperature105-138 °C
Working pressureUp to 0.25 MPa
Air removalGravity or pre-vacuum
Steam supplyElectric generator or external steam, 0.3-0.5 MPa
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 13060, EN 285, ISO 17665-1

What is the Front-Loading Horizontal Rectangular Autoclave?

A floor-standing autoclave with a rectangular chamber of 100 to 1000 L and a horizontal door. It processes large volumes of media, glassware, waste and instruments, with a trolley loading system for high-throughput laboratories and production support.

What is the Front-Loading Horizontal Rectangular Autoclave?

A floor-standing autoclave with a rectangular chamber of 100 to 1000 L and a horizontal door. It processes large volumes of media, glassware, waste and instruments, with a trolley loading system for high-throughput laboratories and production support.

Overview

The horizontal rectangular autoclave has a jacketed stainless steel chamber, typically 100 to 1000 L, with a hinged or sliding door at the front. Loads are prepared on trolleys or carriages that roll directly into the chamber, which reduces lifting and speeds changeover. An external steam supply or integrated electric steam generator feeds the chamber and jacket. Pre-vacuum or gravity cycles are available, and programs include liquid, waste, textile and solid cycles with validated hold times, often at 121 or 134 °C. Microprocessor controllers record temperature, pressure and cycle numbers, with printers or networked logging. Industrial build, ASME or PED design and door safety interlocks are standard. The footprint is larger than a vertical unit, and installation needs steam, drain and electrical services.

How does it work?

An autoclave sterilizes by exposing items to saturated steam under pressure. At 103 kPa gauge, steam reaches 121 °C, and at about 205 kPa it reaches 134 °C. Steam condenses on cooler surfaces, releasing latent heat that denatures proteins and destroys microorganisms far faster than dry heat at the same temperature. A cycle has three main phases: air removal, sterilization hold and exhaust or drying. Gravity-displacement units push air out through a drain by steam flow, while pre-vacuum units use a vacuum pump to remove air before steam admission, which penetrates porous loads and hollow instruments. A steam generator or jacket supplies steam, a controller reads temperature and pressure sensors, and safety valves, door interlocks and overpressure devices protect users. Validated hold times typically range from 3 to 30 minutes depending on load and temperature.

What are the key features?

  • Rectangular chamber of 100 to 1000 L loaded on trolleys or carriages.
  • Jacketed design reduces condensate and shortens heat-up.
  • Gravity or pre-vacuum cycles with liquid, waste and solid programs.
  • Door safety interlocks and overpressure protection to pressure vessel code.
  • Microprocessor control with printed or networked batch records.
  • Electric or external steam supply options.

What are the technical specifications?

A typical front-loading horizontal rectangular autoclave configuration offers chamber volume of 100-1000 L, chamber dimensions (example 300 L) of About 600 × 600 × 830 mm, sterilization temperature of 105-138 °C, working pressure of Up to 0.25 MPa, air removal of Gravity or pre-vacuum and steam supply of Electric generator or external steam, 0.3-0.5 MPa. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Front-Loading Horizontal Rectangular Autoclave is used in high-volume media preparation, laboratory waste decontamination, glassware and equipment sterilization and production support sterilization. Across the wider Autoclaves class, laboratories also deploy it for microbiology media sterilization, laboratory waste decontamination and glassware and instrument sterilization.

Which standards and certifications apply?

Relevant standards and methods include EN 13060, EN 285, ISO 17665-1, ISO 11138, ASME BPVC Section VIII, GB 8599 and EN 61010-2-040. Certification candidates for this model are CE, PED 2014/68/EU and ASME U-stamp; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the autoclave on a level floor with clearances specified by the maker for service and ventilation, and provide a drain, water supply and electrical circuit sized to the heater. Use distilled, deionized or conditioned water as specified to limit scale. Pressure vessels are regulated in most countries, so arrange registration, periodic inspection and operator training. Qualify the unit with installation and operational checks, then validate each load type using thermocouples and biological indicators such as Geobacillus stearothermophilus spores. Perform Bowie-Dick or helix tests daily on vacuum models. Inspect door seals, gaskets and safety valves regularly, descale the chamber and steam generator, and calibrate sensors annually. Never autoclave sealed containers, solvents or bleach-containing waste.

How do I select the right Front-Loading Horizontal Rectangular Autoclave?

Select the horizontal rectangular model for higher throughput, trolley loading and large loads. Vertical units suit smaller laboratories. Specify chamber volume, door arrangement, steam source, cycle types, pressure code and data output in the RFQ. Confirm utility availability.

How does it compare with other Autoclaves variants?

Match the autoclave to the load and the level of assurance required. Liquids, glassware and waste can be processed in gravity cycles, while wrapped instruments, porous textiles and hollow devices need pre-vacuum to remove air. Select chamber volume from the largest load and throughput, typically 18 L for small benchtop units to 1000 L or more for floor-standing models. Decide between top-loading vertical units for economy, front-loading horizontal units for ergonomics, and double-door pass-through units to separate clean and contaminated zones. Check cycle options, such as liquid, waste and dry cycles, printer or data logging, and validation support. Confirm the pressure vessel code, steam source and water quality, and compare electrical or steam supply requirements and installation space, including door swing and drainage.

Full specifications

Full specifications
Chamber volume100-1000 L
Chamber dimensions (example 300 L)About 600 × 600 × 830 mm
Sterilization temperature105-138 °C
Working pressureUp to 0.25 MPa
Air removalGravity or pre-vacuum
Steam supplyElectric generator or external steam, 0.3-0.5 MPa
Door typeHinged or sliding, power-assisted
Chamber materialSUS316L stainless steel
Loading systemTrolley with rail guides
Power supply380 V, 50 Hz, 3 phase

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • High-volume media preparation
  • Laboratory waste decontamination
  • Glassware and equipment sterilization
  • Production support sterilization

Key features

  • Rectangular chamber of 100 to 1000 L loaded on trolleys or carriages.
  • Jacketed design reduces condensate and shortens heat-up.
  • Gravity or pre-vacuum cycles with liquid, waste and solid programs.
  • Door safety interlocks and overpressure protection to pressure vessel code.
  • Microprocessor control with printed or networked batch records.
  • Electric or external steam supply options.

Frequently asked questions about Front-Loading Horizontal Rectangular Autoclave

It needs electrical supply, water for the generator and cooling, drainage to a heat-tolerant drain and, in some installations, external steam and compressed air. Confirm the list with the supplier before site preparation.