Double-Door Pass-Through Dry Heat Sterilizer — product photo

Double-Door Pass-Through Dry Heat Sterilizer

双门传递式干热灭菌器

  • SKU DHS-0004
  • Dry Heat Sterilizers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • GMP-oriented documentation (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature rangeAmbient +10 to 300 °C (350 °C optional)
Chamber volume150-1000 L
Temperature uniformity±5 °C at 250 °C
Door arrangementTwo doors, electronically interlocked
Air circulationForced, HEPA-filtered optional
Chamber materialSUS316L stainless steel
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1211>, Ph. Eur. 5.1.1, USP <1228.1> Dry heat depyrogenation

What is the Double-Door Pass-Through Dry Heat Sterilizer?

A dry heat sterilizer with interlocked loading and unloading doors that separates the unclean and clean sides of a wall. It supports sterile preparation rooms and pharmaceutical facilities by keeping sterilized items from passing back through contaminated areas.

What is the Double-Door Pass-Through Dry Heat Sterilizer?

A dry heat sterilizer with interlocked loading and unloading doors that separates the unclean and clean sides of a wall. It supports sterile preparation rooms and pharmaceutical facilities by keeping sterilized items from passing back through contaminated areas.

Overview

The pass-through dry heat sterilizer is installed in a wall between a preparation area and a clean room. Items are loaded from the unclean side, sterilized or depyrogenated, and removed from the clean side after the cycle ends. Door interlocks keep both doors from opening at the same time, and the clean-side door can be locked until cycle success is confirmed. Chambers of 150 to 1000 L have forced air circulation, and many models filter supply air with HEPA media. Stainless steel finishes and flush, smooth surfaces aid cleaning and meet cleanroom expectations. Programmable controllers, printers or network logging and validated load maps provide records. Installation requires wall openings, service access and coordination with airflow cascades.

How does it work?

Dry heat sterilization kills microorganisms by oxidation and protein denaturation in the absence of moisture. Because air conducts heat less efficiently than steam, higher temperatures and longer times are needed, for example 160 °C for 120 minutes, 170 °C for 60 minutes or 180 °C for 30 minutes. A heated chamber uses electric heating elements, and either natural gravity convection or a fan circulates air to equalize temperature. Fan-forced models reduce gradients and speed heat-up. A controller reads a platinum resistance or thermocouple sensor, and an independent overtemperature cut-out protects the unit. Timing begins when the coldest point in the load reaches the set temperature. Depyrogenation ovens run at 250 to 350 °C to destroy endotoxin, often with HEPA-filtered air supply. Insulated walls and a sealed door limit heat loss.

What are the key features?

  • Interlocked loading and unloading doors separate unclean and clean zones.
  • Clean-side door can be locked until cycle success is confirmed.
  • Forced air circulation with optional HEPA-filtered supply.
  • Flush stainless steel surfaces suit cleanroom cleaning.
  • Printer or network logging with validated load maps.
  • Chamber volumes from 150 to 1000 L.

What are the technical specifications?

A typical double-door pass-through dry heat sterilizer configuration offers temperature range of Ambient +10 to 300 °C (350 °C optional), chamber volume of 150-1000 L, temperature uniformity of ±5 °C at 250 °C, door arrangement of Two doors, electronically interlocked, air circulation of Forced, HEPA-filtered optional and chamber material of SUS316L stainless steel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Double-Door Pass-Through Dry Heat Sterilizer is used in sterile preparation rooms, pharmaceutical cleanroom support, endotoxin-free labware processing and hospital pharmacy compounding support. Across the wider Dry Heat Sterilizers class, laboratories also deploy it for glassware sterilization, metal instrument sterilization and depyrogenation of vials and glassware.

Which standards and certifications apply?

Relevant standards and methods include USP <1211>, Ph. Eur. 5.1.1, USP <1228.1> Dry heat depyrogenation, ISO 20857, EN 61010-2-010, GB/T 30690 and EN 13060. Certification candidates for this model are CE, ISO 13485 manufacturing and GMP-oriented documentation; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the sterilizer on a non-combustible surface with clearance for ventilation and keep flammable materials away. Use a dedicated electrical circuit sized for the heater. Load items in racks so air can circulate, and do not overfill. Wrap or cover items with aluminum foil or place them in metal or borosilicate containers that tolerate the temperature. Start timing at the set temperature for the coldest point, which is verified with thermocouples during validation. Use chemical indicators or biological indicators such as Bacillus atrophaeus spores to verify cycles. Allow the load to cool before opening, since glass can crack with thermal shock. Calibrate the temperature sensor annually and check door seals and fans regularly. Follow burn-safety rules when unloading.

How do I select the right Double-Door Pass-Through Dry Heat Sterilizer?

Select the pass-through model when sterilized items must enter a clean area without re-exposure to unclean spaces. A single-door oven is enough otherwise. Specify wall thickness, door interlock logic, HEPA grade, maximum temperature, mapping and data output.

How does it compare with other Dry Heat Sterilizers variants?

Decide first whether you need sterilization, which runs at 160 to 180 °C, or depyrogenation, which needs 250 °C or above. Then choose between gravity convection, which is simple and gentle on powders, and forced-air models, which give tighter uniformity and faster cycles. Size the chamber for the largest racks or trays and allow space between items for airflow. Check temperature range, uniformity across the chamber, programmable cycles and cooling rate. Regulated laboratories need data logging, validated load mapping and, for pharmaceutical use, HEPA filtration and double-door configurations. Confirm that the materials to be processed tolerate the temperature. Plastics, rubber, liquids, and most textiles are unsuitable, and sharp instruments may lose temper at higher temperatures.

Full specifications

Full specifications
Temperature rangeAmbient +10 to 300 °C (350 °C optional)
Chamber volume150-1000 L
Temperature uniformity±5 °C at 250 °C
Door arrangementTwo doors, electronically interlocked
Air circulationForced, HEPA-filtered optional
Chamber materialSUS316L stainless steel
Wall thickness accommodated100-200 mm
Cooling methodFiltered air cooling, programmable
Data outputPrinter, USB, Ethernet
Power supply380 V, 50 Hz, 3 phase

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Sterile preparation rooms
  • Pharmaceutical cleanroom support
  • Endotoxin-free labware processing
  • Hospital pharmacy compounding support

Key features

  • Interlocked loading and unloading doors separate unclean and clean zones.
  • Clean-side door can be locked until cycle success is confirmed.
  • Forced air circulation with optional HEPA-filtered supply.
  • Flush stainless steel surfaces suit cleanroom cleaning.
  • Printer or network logging with validated load maps.
  • Chamber volumes from 150 to 1000 L.

Frequently asked questions about Double-Door Pass-Through Dry Heat Sterilizer

It avoids carrying sterilized glassware back through unclean areas. Loads enter from one side and leave on the clean side, which reduces contamination risk in aseptic operations.

Request a quotation for the Double-Door Pass-Through Dry Heat Sterilizer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote