

Anodic Stripping Voltammetry Trace Metal Analyzer
阳极溶出伏安痕量金属分析仪
- SKU ELC-0005
- Electrochemical Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurable metals | Pb, Cd, Cu, Zn, Tl, Sb, Bi, Ni, Co (by method) |
|---|---|
| Detection limit (Pb, Cd) | 0.1–1 µg/L (120 s deposition) |
| Linear range | 0.5–200 µg/L |
| Deposition time | 0–999 s |
| Potential range | ±2.0 V |
| Potential resolution | 0.1 mV |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D1293, ASTM D1125, ASTM D888
What is the Anodic Stripping Voltammetry Trace Metal Analyzer?
An anodic stripping voltammetry analyzer pre-concentrates metal ions onto an electrode and then strips them off while recording current, giving ppb-level lead, cadmium, copper and zinc. It is a low-cost alternative to atomic spectroscopy for water, food and plating-bath screening.
What is the Anodic Stripping Voltammetry Trace Metal Analyzer?
An anodic stripping voltammetry analyzer pre-concentrates metal ions onto an electrode and then strips them off while recording current, giving ppb-level lead, cadmium, copper and zinc. It is a low-cost alternative to atomic spectroscopy for water, food and plating-bath screening.
Overview
In the deposition step, a negative potential held for 30–300 seconds reduces metal ions from stirred solution into a mercury-free working electrode such as bismuth film, gold or glassy carbon. The potential is then scanned anodically by square-wave or differential pulse, and each metal oxidizes at a characteristic potential, for example cadmium near −0.75 V and lead near −0.55 V versus Ag/AgCl, giving peaks proportional to concentration. Quantification uses standard addition in the same sample, which compensates matrix effects. Typical detection limits are 0.1–1 µg/L for Pb and Cd after two-minute deposition. The instrument suits multi-metal screening of acidified water and digested samples, although organic matter requires UV digestion. It runs at lower cost than AAS and is available in portable form.
How does it work?
Electrochemical analysis links an electrical signal to analyte activity or concentration. Potentiometry measures the potential between an indicator electrode, such as a pH glass membrane or ion-selective membrane, and a reference electrode, related to ion activity by the Nernst equation, about 59.16 mV per decade at 25 °C for monovalent ions. Conductometry measures the ability of ions in solution to carry current between electrodes at alternating voltage, with temperature compensation. Amperometric sensors such as Clark cells measure the current from reduction of dissolved oxygen, whereas optical sensors measure luminescence quenching. Voltammetry sweeps potential across a working electrode and records current, with peak position identifying the species and peak height its concentration. Potentiostats control the potential of the working electrode against a reference while measuring current through a counter electrode.
What are the key features?
- Square-wave and differential pulse stripping modes with programmable deposition time
- Mercury-free working electrodes such as bismuth film, gold and glassy carbon
- Automatic standard-addition routine for matrix-compensated quantification
- Simultaneous detection of Pb, Cd, Cu, Zn and other metals in one scan
- Automatic stirrer, purge and reagent dosing options for unattended analysis
- Portable versions for on-site screening of water and soil extracts
What are the technical specifications?
A typical anodic stripping voltammetry trace metal analyzer configuration offers measurable metals of Pb, Cd, Cu, Zn, Tl, Sb, Bi, Ni, Co (by method), detection limit (Pb, Cd) of 0.1–1 µg/L (120 s deposition), linear range of 0.5–200 µg/L, deposition time of 0–999 s, potential range of ±2.0 V and potential resolution of 0.1 mV. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Anodic Stripping Voltammetry Trace Metal Analyzer is used in lead and cadmium in drinking water, trace metals in electroplating baths and wastewater, heavy metal screening of food extracts, copper and zinc in sea water and field screening of mining drainage. Across the wider Electrochemical Analyzers class, laboratories also deploy it for pH and ion control in water and process chemistry, conductivity of ultrapure and boiler water and dissolved oxygen in wastewater and fermentation.
Which standards and certifications apply?
Relevant standards and methods include ASTM D1293, ASTM D1125, ASTM D888, ISO 10523, ISO 7888, USP <645>, ASTM G5 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Electrode condition dominates accuracy. Calibrate pH meters with two or three fresh NIST-traceable buffers bracketing the sample, record slope, which should be 95–105% of theoretical, and replace electrodes with slow response. Store glass electrodes in proper storage solution, never distilled water. Calibrate conductivity cells with certified standards such as 1413 µS/cm at 25 °C and verify temperature compensation. Keep optical dissolved oxygen caps within their service life. Reference electrode fill solutions need topping up and periodic replacement. For potentiostats, use shielded cables, a Faraday cage for nA-level work and correct connection to the working, reference and counter electrodes. Maintain calibration records suited to ISO/IEC 17025.
How do I select the right Anodic Stripping Voltammetry Trace Metal Analyzer?
Select this variant for low-cost, sensitive screening of a few heavy metals in liquids, especially on-site. For regulatory multi-element reporting choose ICP-OES or ICP-MS. In an RFQ, specify target metals and limits, sample types needing digestion, electrode type, automation level, portability, and reference methods such as ISO 17294 for confirmation.
How does it compare with other Electrochemical Analyzers variants?
Choose by the measured parameter and accuracy demanded. Routine pH, mV and ion concentration call for a benchtop pH or ion meter with suitable electrodes, and resolution of 0.001 pH is worthwhile only when electrodes and buffers support it. Ultrapure water, boiler water and process streams need a conductivity meter with the right cell constant, with 0.01 for ultrapure water and 1.0 for general use. Dissolved oxygen in water and fermentation suit optical sensors, which avoid electrolyte maintenance. Trace heavy metals at ppb level suit stripping voltammetry. Corrosion, battery and materials research require a potentiostat with adequate current range and impedance capability. Also consider data integrity features, electrode availability and calibration automation.
Full specifications
| Measurable metals | Pb, Cd, Cu, Zn, Tl, Sb, Bi, Ni, Co (by method) |
|---|---|
| Detection limit (Pb, Cd) | 0.1–1 µg/L (120 s deposition) |
| Linear range | 0.5–200 µg/L |
| Deposition time | 0–999 s |
| Potential range | ±2.0 V |
| Potential resolution | 0.1 mV |
| Scan techniques | Square-wave, differential pulse, linear sweep |
| Repeatability | RSD ≤ 5% at 10 µg/L |
| Sample volume | 10–20 mL |
| Analysis time per metal set | ≈ 5 min |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Lead and cadmium in drinking water
- Trace metals in electroplating baths and wastewater
- Heavy metal screening of food extracts
- Copper and zinc in sea water
- Field screening of mining drainage
Key features
- Square-wave and differential pulse stripping modes with programmable deposition time
- Mercury-free working electrodes such as bismuth film, gold and glassy carbon
- Automatic standard-addition routine for matrix-compensated quantification
- Simultaneous detection of Pb, Cd, Cu, Zn and other metals in one scan
- Automatic stirrer, purge and reagent dosing options for unattended analysis
- Portable versions for on-site screening of water and soil extracts
Frequently asked questions about Anodic Stripping Voltammetry Trace Metal Analyzer
Peak response depends on matrix components that affect deposition and stripping, so external calibration can be biased. Adding known spikes of the analyte to the same sample and extrapolating the response corrects for this matrix effect.
For screening of Pb, Cd, Cu and Zn in relatively clean liquids it can match AAS sensitivity at lower cost. For regulatory reporting, complex matrices or many elements, AAS or ICP methods remain the validated reference techniques.
Organic compounds adsorbing on the electrode, overlapping peaks of Cu and Zn, and intermetallic compounds can distort results. UV digestion, acidification and optimized deposition potential reduce these interferences.
A pH meter reads hydrogen ion activity from a glass electrode. An ion meter also reads other ions, such as fluoride, nitrate or sodium, with ion-selective electrodes and reports concentration using calibration standards and ionic strength adjusters. Most benchtop units combine both functions.
Ion mobility rises with temperature, increasing conductivity by roughly 2% per °C for most aqueous solutions. Meters use automatic temperature compensation to report conductivity at a reference of 25 °C, using a linear coefficient or nonlinear function for natural and ultrapure water.
With good care, pH glass electrodes last 6–24 months. Replace when calibration slope falls below about 92–95%, response is slow, or readings drift. Extreme pH, high temperature, fluoride and protein-rich samples shorten lifetime.
Related models






