Optical Dissolved Oxygen Meter
光学溶解氧仪
- SKU ELC-0003
- Electrochemical Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Oxygen range | 0–20 mg/L (0–200% saturation) |
|---|---|
| Accuracy | ±0.1 mg/L (0–8 mg/L) |
| Resolution | 0.01 mg/L |
| Response time (T90) | < 30 s |
| Temperature range | 0–50 °C |
| Salinity correction | 0–70 PSU |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D1293, ASTM D1125, ASTM D888
What is the Optical Dissolved Oxygen Meter?
An optical dissolved oxygen meter measures oxygen by luminescence quenching of a sensor cap, reading mg/L or percent saturation without electrolyte or membrane replacement. It is used in wastewater treatment, aquaculture, fermentation, BOD testing and environmental water surveys.
What is the Optical Dissolved Oxygen Meter?
An optical dissolved oxygen meter measures oxygen by luminescence quenching of a sensor cap, reading mg/L or percent saturation without electrolyte or membrane replacement. It is used in wastewater treatment, aquaculture, fermentation, BOD testing and environmental water surveys.
Overview
A blue LED excites a luminophore in the sensor cap, and the red luminescence lifetime or phase shift is shortened in proportion to oxygen partial pressure, which is converted to concentration using temperature, salinity and barometric pressure corrections. Unlike Clark polarographic sensors, optical probes consume no oxygen, so no stirring is required, and there is no electrolyte or membrane to maintain. The sensor cap typically lasts 12 months and is replaced with a stored calibration. Typical measuring range is 0–20 mg/L with accuracy of ±0.1 mg/L, and response time T90 under 30 seconds. One-point water-saturated air calibration is typically sufficient, with a zero check in sodium sulfite. Cables of 1–10 m and BOD bottle probes are available.
How does it work?
Electrochemical analysis links an electrical signal to analyte activity or concentration. Potentiometry measures the potential between an indicator electrode, such as a pH glass membrane or ion-selective membrane, and a reference electrode, related to ion activity by the Nernst equation, about 59.16 mV per decade at 25 °C for monovalent ions. Conductometry measures the ability of ions in solution to carry current between electrodes at alternating voltage, with temperature compensation. Amperometric sensors such as Clark cells measure the current from reduction of dissolved oxygen, whereas optical sensors measure luminescence quenching. Voltammetry sweeps potential across a working electrode and records current, with peak position identifying the species and peak height its concentration. Potentiostats control the potential of the working electrode against a reference while measuring current through a counter electrode.
What are the key features?
- Luminescence lifetime measurement with no oxygen consumption or flow dependence
- No membrane, electrolyte or polarization time so probe is ready immediately
- Automatic temperature, salinity and barometric pressure compensation
- Replaceable sensor cap with stored calibration coefficients
- BOD bottle probe for stirred five-day oxygen demand tests
- Measurement in mg/L, percent saturation and partial pressure
What are the technical specifications?
A typical optical dissolved oxygen meter configuration offers oxygen range of 0–20 mg/L (0–200% saturation), accuracy of ±0.1 mg/L (0–8 mg/L), resolution of 0.01 mg/L, response time (T90) of < 30 s, temperature range of 0–50 °C and salinity correction of 0–70 PSU. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Optical Dissolved Oxygen Meter is used in activated sludge aeration control, BOD bottle testing, fermentation and cell culture, fish farm and aquaculture monitoring and river and lake water quality surveys. Across the wider Electrochemical Analyzers class, laboratories also deploy it for pH and ion control in water and process chemistry, conductivity of ultrapure and boiler water and dissolved oxygen in wastewater and fermentation.
Which standards and certifications apply?
Relevant standards and methods include ASTM D1293, ASTM D1125, ASTM D888, ISO 10523, ISO 7888, USP <645>, ASTM G5 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Electrode condition dominates accuracy. Calibrate pH meters with two or three fresh NIST-traceable buffers bracketing the sample, record slope, which should be 95–105% of theoretical, and replace electrodes with slow response. Store glass electrodes in proper storage solution, never distilled water. Calibrate conductivity cells with certified standards such as 1413 µS/cm at 25 °C and verify temperature compensation. Keep optical dissolved oxygen caps within their service life. Reference electrode fill solutions need topping up and periodic replacement. For potentiostats, use shielded cables, a Faraday cage for nA-level work and correct connection to the working, reference and counter electrodes. Maintain calibration records suited to ISO/IEC 17025.
How do I select the right Optical Dissolved Oxygen Meter?
Select this variant where low maintenance, no stirring requirement and fast warm-up matter, such as field work, BOD and aeration control. Choose a galvanic or polarographic sensor only where budget or legacy methods demand. In an RFQ, specify measuring range, cable length, probe type including BOD head, logging needs and reference methods such as ISO 17289.
How does it compare with other Electrochemical Analyzers variants?
Choose by the measured parameter and accuracy demanded. Routine pH, mV and ion concentration call for a benchtop pH or ion meter with suitable electrodes, and resolution of 0.001 pH is worthwhile only when electrodes and buffers support it. Ultrapure water, boiler water and process streams need a conductivity meter with the right cell constant, with 0.01 for ultrapure water and 1.0 for general use. Dissolved oxygen in water and fermentation suit optical sensors, which avoid electrolyte maintenance. Trace heavy metals at ppb level suit stripping voltammetry. Corrosion, battery and materials research require a potentiostat with adequate current range and impedance capability. Also consider data integrity features, electrode availability and calibration automation.
Full specifications
| Oxygen range | 0–20 mg/L (0–200% saturation) |
|---|---|
| Accuracy | ±0.1 mg/L (0–8 mg/L) |
| Resolution | 0.01 mg/L |
| Response time (T90) | < 30 s |
| Temperature range | 0–50 °C |
| Salinity correction | 0–70 PSU |
| Barometric correction | 400–850 mmHg (internal sensor) |
| Cable length | 1, 3 or 10 m |
| Sensor cap life | ≈ 12 months |
| Flow dependence | None (no stirring required) |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Activated sludge aeration control
- BOD bottle testing
- Fermentation and cell culture
- Fish farm and aquaculture monitoring
- River and lake water quality surveys
Key features
- Luminescence lifetime measurement with no oxygen consumption or flow dependence
- No membrane, electrolyte or polarization time so probe is ready immediately
- Automatic temperature, salinity and barometric pressure compensation
- Replaceable sensor cap with stored calibration coefficients
- BOD bottle probe for stirred five-day oxygen demand tests
- Measurement in mg/L, percent saturation and partial pressure
Frequently asked questions about Optical Dissolved Oxygen Meter
Optical sensors measure oxygen by luminescence quenching without consuming oxygen, so there is no depleted layer at the sensor surface. Polarographic sensors consume oxygen and require flow of roughly 0.3 m/s to give a correct reading.
A one-point calibration in water-saturated air is typically used, with the probe placed in a calibration sleeve at stable temperature. An optional zero point is checked in a 2% sodium sulfite solution, and barometric pressure is applied automatically.
Few species interfere, but chlorine, sulfur dioxide and some solvents can affect luminophores, and strong ambient light or biofilm on the cap can bias readings. Clean the cap gently and keep it within service life.
A pH meter reads hydrogen ion activity from a glass electrode. An ion meter also reads other ions, such as fluoride, nitrate or sodium, with ion-selective electrodes and reports concentration using calibration standards and ionic strength adjusters. Most benchtop units combine both functions.
Ion mobility rises with temperature, increasing conductivity by roughly 2% per °C for most aqueous solutions. Meters use automatic temperature compensation to report conductivity at a reference of 25 °C, using a linear coefficient or nonlinear function for natural and ultrapure water.
With good care, pH glass electrodes last 6–24 months. Replace when calibration slope falls below about 92–95%, response is slow, or readings drift. Extreme pH, high temperature, fluoride and protein-rich samples shorten lifetime.
Related models






UV-Fluorescence Total Sulfur and Chemiluminescence Nitrogen Analyzer
紫外荧光总硫与化学发光总氮分析仪
- CE (to be confirmed)
- +2