Standard Differential Thermal Analyzer
标准型差热分析仪
- SKU DTA-0001
- DTA
- CE (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | −150–700 °C |
|---|---|
| Heating rate | 0.5–50 °C/min |
| Thermocouple type | Type K or Type S platinum |
| Temperature accuracy | ±2 °C |
| Signal resolution | 0.1 °C |
| Sample mass | 10–50 mg typical |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E967, ASTM E794, ASTM D3418
What is the Standard Differential Thermal Analyzer?
A standard differential thermal analyzer covers about minus 150 to 700 degrees Celsius with platinum or chromel-alumel thermocouples, giving qualitative thermal events for polymers, organics, minerals and salts. It is the basic configuration for teaching and routine identification work.
What is the Standard Differential Thermal Analyzer?
A standard differential thermal analyzer covers about minus 150 to 700 degrees Celsius with platinum or chromel-alumel thermocouples, giving qualitative thermal events for polymers, organics, minerals and salts. It is the basic configuration for teaching and routine identification work.
Overview
The instrument uses a sample holder with two wells and a differential thermocouple that measures the temperature difference between the sample and an inert reference, usually calcined alumina. Heating rates from 0.5 to 50 degrees Celsius per minute are available, with purge gas at a controlled flow. The signal is displayed in microvolts and converted to a temperature difference scale, and the software reports peak onset, peak maximum and peak area. Sensitivity is adequate for dehydration, melting, crystallization, polymorphic transitions and decomposition of organic salts, with a typical temperature resolution of about 0.1 degrees Celsius in the signal. Samples of 10 to 50 milligrams in alumina or platinum crucibles are typical. Cooling may use liquid nitrogen, compressed air or a mechanical cooler, and the instrument is often combined with a thermogravimetric module for simultaneous work.
How does it work?
The sample and a thermally inert reference, usually calcined alumina, sit in the same furnace and are heated on the same program. A differential thermocouple or two matched thermocouples measure the temperature difference between them, recorded as microvolts against temperature or time, alongside the sample temperature. When the sample undergoes a transition that absorbs heat, its temperature lags the reference and produces an endothermic peak; exothermic reactions such as crystallization or oxidation give a peak in the opposite direction. The peak position identifies the transition temperature and the peak area is roughly proportional to the enthalpy change, although DTA is less quantitative than DSC because the heat path is not calibrated in absolute terms. Sensitivity depends on sample mass, packing density, thermocouple position and atmosphere. Typical samples are 10 to 100 milligrams, and inert, oxidising, reducing or vacuum atmospheres are selectable.
What are the key features?
- Temperature range from −150 to 700 °C with sub-ambient cooling
- Differential thermocouple with 0.1 °C signal resolution
- Heating rates from 0.5 to 50 °C/min
- Alumina or platinum crucibles with matched reference
- Software reporting peak onset, maximum and area
- Purge gas control for inert, oxidising or reducing atmospheres
What are the technical specifications?
A typical standard differential thermal analyzer configuration offers temperature range of −150–700 °C, heating rate of 0.5–50 °C/min, thermocouple type of Type K or Type S platinum, temperature accuracy of ±2 °C, signal resolution of 0.1 °C and sample mass of 10–50 mg typical. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Standard Differential Thermal Analyzer is used in clay and mineral identification, polymer and organic salt screening, teaching and method development, salt hydrate and dehydration studies and food and pharmaceutical pre-screening. Across the wider DTA class, laboratories also deploy it for clay and mineral phase identification, cement and gypsum dehydration studies and ceramic and refractory development.
Which standards and certifications apply?
Relevant standards and methods include ASTM E967, ASTM E794, ASTM D3418, ISO 11357-1, IEC 61010-1 and GB/T 13464. Certification candidates for this model are CE, IEC 61010-1 safety and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Package the sample uniformly and keep mass and packing the same as the reference to avoid baseline distortion, and dilute reactive samples with alumina when necessary. Select crucible and thermocouple materials that do not react with the sample at the working temperature, and use a platinum or alumina holder for oxidising conditions. Purge the furnace with the intended gas at a stable flow, and verify the thermocouple pair against melting point standards such as indium, tin, aluminium, silver or gold depending on range. Record the crucible type, sample mass, gas, flow rate and heating rate with every curve. Thermal analysis of minerals often shows overlapping peaks that require a consistent, documented heating rate and reference material to be compared between laboratories, so method details should be exchanged with results.
How do I select the right Standard Differential Thermal Analyzer?
Choose the standard configuration for qualitative thermal analysis below 700 degrees Celsius where peak temperatures, not enthalpies, are the required output. If heat flow or heat capacity data are needed, select a DSC. In an RFQ, specify thermocouple type, crucible material, gas control and calibration standards.
How does it compare with other DTA variants?
The decisive parameter is the temperature range, because DTA is chosen mainly when transitions lie above the working range of a DSC: minerals, clays, cements, refractories and glasses often require 1500 to 1600 degrees Celsius, and some slags and alloys need graphite furnaces above 2000 degrees Celsius. Below 700 degrees Celsius a DSC is usually a better choice because it also gives enthalpies. After range, consider the thermocouple type and hence the maximum temperature, the crucible and thermocouple materials compatible with the sample, atmosphere and vacuum control, sensitivity to small transitions, and whether automation is required. Peak resolution depends on the heat path, so sample packing and mass must be matched between runs. For routine quality control, an automated instrument with a sample changer reduces operator time, and calibration with melting point and phase transition references should be part of the method.
Full specifications
| Temperature range | −150–700 °C |
|---|---|
| Heating rate | 0.5–50 °C/min |
| Thermocouple type | Type K or Type S platinum |
| Temperature accuracy | ±2 °C |
| Signal resolution | 0.1 °C |
| Sample mass | 10–50 mg typical |
| Crucible materials | Alumina, platinum, quartz |
| Atmosphere | Nitrogen, argon, air, vacuum option |
| Cooling | Liquid nitrogen, air or mechanical |
| Data output | Curve files with peak evaluation |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Clay and mineral identification
- Polymer and organic salt screening
- Teaching and method development
- Salt hydrate and dehydration studies
- Food and pharmaceutical pre-screening
Key features
- Temperature range from −150 to 700 °C with sub-ambient cooling
- Differential thermocouple with 0.1 °C signal resolution
- Heating rates from 0.5 to 50 °C/min
- Alumina or platinum crucibles with matched reference
- Software reporting peak onset, maximum and area
- Purge gas control for inert, oxidising or reducing atmospheres
Frequently asked questions about Standard Differential Thermal Analyzer
Only approximately. Peak area correlates with transition enthalpy, but the heat path is not calibrated in absolute units, so DTA is used for temperatures and relative magnitudes. For reliable enthalpy values, use a DSC with indium calibration.
The reference should have similar heat capacity and packing to the sample so the baseline stays flat and small peaks remain visible. Calcined alumina is inert over the working range and can be diluted with sample to match conditions when the material is unusual.
Not by itself. A simultaneous thermal analyzer combines DTA with a thermobalance so that mass loss and thermal events are recorded from one sample in a single run, which is common when dehydration and decomposition overlap.
DTA records the temperature difference between sample and reference and is mainly qualitative, while DSC measures heat flow and can be calibrated to give transition enthalpies. DTA is usually preferred at very high temperatures where DSC cells are difficult to build.
Clay minerals show characteristic dehydration, dehydroxylation and recrystallization events at defined temperatures, giving a fingerprint pattern. Kaolinite, for example, loses hydroxyl groups near 500 degrees Celsius and recrystallizes near 980 degrees Celsius, which helps identify the clay type.
Temperature is calibrated with high-purity melting point standards spanning the working range, in contrast to DSC where enthalpies are also calibrated. Peak onset rather than peak maximum is commonly used as the transition temperature, and the same heating rate must be used for standards and samples.
Related models