Automated Differential Thermal Analyzer — product photo

Automated Differential Thermal Analyzer

自动进样差热分析仪

  • SKU DTA-0005
  • DTA
  • CE (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Autosampler capacity20–60 crucibles
Temperature rangeAmbient–1600 °C
Heating rate1–30 °C/min
Temperature accuracy±3 °C
Methods per sequenceUp to 30, individually assigned
Calibration checkSchedulable with internal standard
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E967, ASTM E794, ASTM D3418

What is the Automated Differential Thermal Analyzer?

An automated differential thermal analyzer adds a robotic sample changer and automatic calibration checks so that long sequences of mineral, cement or ceramic samples run unattended. It is used in production control and contract testing laboratories with high sample numbers.

What is the Automated Differential Thermal Analyzer?

An automated differential thermal analyzer adds a robotic sample changer and automatic calibration checks so that long sequences of mineral, cement or ceramic samples run unattended. It is used in production control and contract testing laboratories with high sample numbers.

Overview

The autosampler stores crucibles in trays, places each sample and matched reference into the furnace, runs the assigned method and removes the crucible before the next position. Sequences can mix methods with different end temperatures, heating rates and atmospheres, and the software evaluates peaks, compares them to specifications and produces reports. Because minerals and cements often show broad, overlapping peaks, the evaluation parameters are fixed in the method and applied identically to every sample, which improves reproducibility between operators. Temperature calibration checks can be scheduled between batches with an internal standard. Practical considerations include furnace cooling time between runs, crucible handling precision, the risk of sample spillage contaminating the holder, and the need to re-verify performance after any holder or thermocouple replacement.

How does it work?

The sample and a thermally inert reference, usually calcined alumina, sit in the same furnace and are heated on the same program. A differential thermocouple or two matched thermocouples measure the temperature difference between them, recorded as microvolts against temperature or time, alongside the sample temperature. When the sample undergoes a transition that absorbs heat, its temperature lags the reference and produces an endothermic peak; exothermic reactions such as crystallization or oxidation give a peak in the opposite direction. The peak position identifies the transition temperature and the peak area is roughly proportional to the enthalpy change, although DTA is less quantitative than DSC because the heat path is not calibrated in absolute terms. Sensitivity depends on sample mass, packing density, thermocouple position and atmosphere. Typical samples are 10 to 100 milligrams, and inert, oxidising, reducing or vacuum atmospheres are selectable.

What are the key features?

  • Robotic sample changer for 20 to 60 crucibles
  • Automatic placement of matched sample and reference
  • Mixed methods with different end temperatures and gases
  • Scheduled calibration checks with internal standards
  • Fixed peak evaluation parameters for every sample
  • Report generation with specification comparison and export

What are the technical specifications?

A typical automated differential thermal analyzer configuration offers autosampler capacity of 20–60 crucibles, temperature range of Ambient–1600 °C, heating rate of 1–30 °C/min, temperature accuracy of ±3 °C, methods per sequence of Up to 30, individually assigned and calibration check of Schedulable with internal standard. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automated Differential Thermal Analyzer is used in cement and clinker production control, refractory material incoming inspection, mineral and ore characterisation, contract thermal analysis services and quality control of ceramic raw materials. Across the wider DTA class, laboratories also deploy it for clay and mineral phase identification, cement and gypsum dehydration studies and ceramic and refractory development.

Which standards and certifications apply?

Relevant standards and methods include ASTM E967, ASTM E794, ASTM D3418, ISO 11357-1, IEC 61010-1 and GB/T 13464. Certification candidates for this model are CE, IEC 61010-1 safety and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Package the sample uniformly and keep mass and packing the same as the reference to avoid baseline distortion, and dilute reactive samples with alumina when necessary. Select crucible and thermocouple materials that do not react with the sample at the working temperature, and use a platinum or alumina holder for oxidising conditions. Purge the furnace with the intended gas at a stable flow, and verify the thermocouple pair against melting point standards such as indium, tin, aluminium, silver or gold depending on range. Record the crucible type, sample mass, gas, flow rate and heating rate with every curve. Thermal analysis of minerals often shows overlapping peaks that require a consistent, documented heating rate and reference material to be compared between laboratories, so method details should be exchanged with results.

How do I select the right Automated Differential Thermal Analyzer?

Select the automated configuration when more than about ten similar samples are measured per day and evaluation must be identical between operators. For occasional or exploratory work, manual loading is sufficient. In an RFQ, specify autosampler capacity, method flexibility, report format and calibration-check interval.

How does it compare with other DTA variants?

The decisive parameter is the temperature range, because DTA is chosen mainly when transitions lie above the working range of a DSC: minerals, clays, cements, refractories and glasses often require 1500 to 1600 degrees Celsius, and some slags and alloys need graphite furnaces above 2000 degrees Celsius. Below 700 degrees Celsius a DSC is usually a better choice because it also gives enthalpies. After range, consider the thermocouple type and hence the maximum temperature, the crucible and thermocouple materials compatible with the sample, atmosphere and vacuum control, sensitivity to small transitions, and whether automation is required. Peak resolution depends on the heat path, so sample packing and mass must be matched between runs. For routine quality control, an automated instrument with a sample changer reduces operator time, and calibration with melting point and phase transition references should be part of the method.

Full specifications

Full specifications
Autosampler capacity20–60 crucibles
Temperature rangeAmbient–1600 °C
Heating rate1–30 °C/min
Temperature accuracy±3 °C
Methods per sequenceUp to 30, individually assigned
Calibration checkSchedulable with internal standard
AtmosphereAir, argon, nitrogen
Sample holderAlumina or platinum
Cooling between runsAutomatic, programmable
Data outputCSV, PDF report, LIMS export

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Cement and clinker production control
  • Refractory material incoming inspection
  • Mineral and ore characterisation
  • Contract thermal analysis services
  • Quality control of ceramic raw materials

Key features

  • Robotic sample changer for 20 to 60 crucibles
  • Automatic placement of matched sample and reference
  • Mixed methods with different end temperatures and gases
  • Scheduled calibration checks with internal standards
  • Fixed peak evaluation parameters for every sample
  • Report generation with specification comparison and export

Frequently asked questions about Automated Differential Thermal Analyzer

With a 30-position changer and methods ending at 1000 degrees Celsius at 10 degrees Celsius per minute, roughly 12 to 18 samples complete in an eight-hour unattended period, because each run includes heating, hold and cooling time that cannot be shortened.