Benchtop Thermomechanical Analyzer
台式热机械分析仪
- SKU TMA-0001
- TMA
- CE (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | −150–1000 °C (cooling dependent) |
|---|---|
| Displacement resolution | 1 nm |
| Displacement range | ±5 mm |
| Load range | 0.001–5 N programmable |
| Heating rate | 0.1–50 °C/min |
| Temperature accuracy | ±1 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E831, ASTM E1363, ASTM D696
What is the Benchtop Thermomechanical Analyzer?
A benchtop thermomechanical analyzer uses a vertical push-rod and LVDT displacement sensor with interchangeable probes, covering expansion, compression, penetration, tension and bending. It is the general-purpose instrument for coefficients of thermal expansion and softening temperatures.
What is the Benchtop Thermomechanical Analyzer?
A benchtop thermomechanical analyzer uses a vertical push-rod and LVDT displacement sensor with interchangeable probes, covering expansion, compression, penetration, tension and bending. It is the general-purpose instrument for coefficients of thermal expansion and softening temperatures.
Overview
The instrument combines a nanometre-resolution displacement sensor with a furnace covering minus 150 to 1000 degrees Celsius, depending on the cooling accessory, and a programmable load from 0.001 to 5 newtons. Interchangeable probes and holders convert the same displacement channel into expansion, compression, penetration, tension and three-point bending measurements, and the software applies the probe and holder expansion correction automatically. Typical specifications are a displacement resolution of 1 nanometre, temperature accuracy of 1 degree Celsius and length change measurement over a range of several millimetres. Sample dimensions vary with mode: 5 to 10 mm long rods for expansion, 2 to 10 mm thick discs for penetration, and thin strips or filaments for tension. Purge gas control, optional vacuum and a cooled stage support a wide range of materials, and the instrument is usually the entry point of a thermal analysis laboratory before more specialised dilatometers are added.
How does it work?
A probe rests on the specimen and is connected to a linear variable differential transformer, which converts displacement into an electrical signal with resolution near one nanometre. A furnace programs the temperature while a defined static or oscillating load holds the probe in contact. Depending on the probe and holder fitted, the instrument measures expansion, compression, penetration, tension or three-point bending, and the same displacement channel serves all modes. Coefficient of thermal expansion is calculated from the slope of the expansion curve over a chosen temperature interval, and softening or glass transition temperatures are read from the onset of probe penetration. Calibration uses reference materials of known expansion such as fused silica or aluminium, plus melting point standards for the temperature channel. Probe material, load and contact geometry must be recorded because they influence the measured displacement, and sample preparation must give parallel, flat faces.
What are the key features?
- Nanometre-resolution LVDT displacement sensor
- Interchangeable probes for expansion, compression, penetration, tension and bending
- Furnace from −150 to 1000 °C with liquid nitrogen option
- Programmable static load from 0.001 to 5 N
- Automatic probe and holder expansion correction
- Purge gas and optional vacuum atmosphere control
What are the technical specifications?
A typical benchtop thermomechanical analyzer configuration offers temperature range of −150–1000 °C (cooling dependent), displacement resolution of 1 nm, displacement range of ±5 mm, load range of 0.001–5 N programmable, heating rate of 0.1–50 °C/min and temperature accuracy of ±1 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Thermomechanical Analyzer is used in coefficient of thermal expansion of polymers, softening and glass transition by penetration, film and fibre dimensional change, coating and laminate expansion and adhesive and sealant testing. Across the wider TMA class, laboratories also deploy it for coefficient of thermal expansion of metals and ceramics, polymer softening and glass transition and electronic substrate and packaging materials.
Which standards and certifications apply?
Relevant standards and methods include ASTM E831, ASTM E1363, ASTM D696, ISO 11359-1, ISO 11359-2 and IEC 61010-1. Certification candidates for this model are CE, IEC 61010-1 safety and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Prepare specimens with parallel, flat and smooth faces, and record the original length precisely, because expansion results are normalized to it. Keep the load low enough to avoid deforming the sample, and allow the probe to settle at the starting temperature before beginning the ramp. Verify the expansion channel with a certified reference such as fused silica or aluminium and check the temperature channel with melting point standards. Beware of systematic artefacts: probe and holder expansion must be subtracted, and soft samples can show apparent shrinkage from creep under load. Keep the furnace and probe clean, replace worn probes, and use the correct purge gas to avoid oxidation or reaction with the specimen. Record mode, load, probe material, gas and calibration data with every curve.
How do I select the right Benchtop Thermomechanical Analyzer?
Choose the benchtop instrument for flexible, general-purpose work where several measurement modes are needed on polymers, films and composites. For high-precision expansion of ceramics and metals, a horizontal dilatometer is more appropriate. In an RFQ, specify modes, temperature range, displacement resolution, load range and probe materials.
How does it compare with other TMA variants?
Decide the measurement mode first, because it dictates the probe and holder: expansion requires a flat-ended probe and often a horizontal or vertical dilatometer configuration, penetration and compression suit polymers and soft materials, tension suits films and fibres, and three-point bending suits rigid bars. Then set the temperature range, since it determines whether the furnace uses quartz, alumina or graphite and whether cooling uses liquid nitrogen or mechanical refrigeration. Displacement resolution matters most for thin films and low-expansion ceramics, where nanometre sensitivity is needed. Load range and control quality decide whether soft, low-modulus samples can be measured without deformation caused by the probe itself. Check the atmosphere and vacuum options, calibration standards supplied, sample preparation tooling and whether the instrument can be upgraded with a humidity generator or an automatic sample changer.
Full specifications
| Temperature range | −150–1000 °C (cooling dependent) |
|---|---|
| Displacement resolution | 1 nm |
| Displacement range | ±5 mm |
| Load range | 0.001–5 N programmable |
| Heating rate | 0.1–50 °C/min |
| Temperature accuracy | ±1 °C |
| Probe materials | Fused silica, alumina, quartz |
| Measurement modes | Expansion, compression, penetration, tension, bending |
| Atmosphere | Nitrogen, argon, air, vacuum option |
| Sample length | 2–25 mm depending on mode |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Coefficient of thermal expansion of polymers
- Softening and glass transition by penetration
- Film and fibre dimensional change
- Coating and laminate expansion
- Adhesive and sealant testing
Key features
- Nanometre-resolution LVDT displacement sensor
- Interchangeable probes for expansion, compression, penetration, tension and bending
- Furnace from −150 to 1000 °C with liquid nitrogen option
- Programmable static load from 0.001 to 5 N
- Automatic probe and holder expansion correction
- Purge gas and optional vacuum atmosphere control
Frequently asked questions about Benchtop Thermomechanical Analyzer
A blank or calibration run with the same probe, holder and temperature program is subtracted from the sample curve, or the software applies the known expansion coefficient of the probe material. Both approaches require the probe material and geometry to be recorded with the data.
Use the lowest load that keeps the probe in reliable contact, typically 0.01 to 0.1 newtons for soft polymers and 0.5 to 2 newtons for rigid ceramics and metals. Run one check at a second load to confirm the result is not influenced by creep.
Not usually. Expansion uses a flat-ended probe with a large contact area to measure length change, while penetration uses a small hemispherical or pointed tip that presses into the surface. The probe must be changed and the correct correction factor applied for each mode.
It measures dimensional change of a specimen under a controlled load as temperature changes. From that curve it determines thermal expansion coefficient, shrinkage on curing or sintering, softening and penetration onset, glass transition by expansion, and dimensional stability of films and composites.
The probe and holder also expand with temperature, and their contribution must be subtracted to isolate the sample behaviour. Fused silica has a very low and well-known expansion, so it is used for low-expansion samples and as the reference material for calibration.
It is the slope of the expansion curve divided by the original specimen length, expressed in parts per million per degree Celsius. The value depends strongly on the temperature interval chosen, so the interval must be stated, for example 20 to 100 degrees Celsius.
Related models