Skip to main content
Lab Manufacturers China
Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents — product photo

Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents

荧光素偶联单克隆抗体检测组合试剂

  • SKU CYR-0001
  • Cytometry Reagents
  • ISO 13485 manufacturing (to be confirmed)
  • CE-IVD marking for selected products (to be confirmed)
  • RUO labeling (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Antibody concentration0.1–0.5 mg/mL
FormatLiquid; dried/lyophilized cocktails available
Typical test volume5 µL (pre-titrated) per 10^6 cells
Vial size0.1 mL, 0.5 mL, 2 mL
FluorochromesFITC, PE, PerCP, APC, tandem and polymer dyes
Excitation lasers405, 488, 561, 640 nm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI H62, CLSI H43, ISO 20391-2

What is the Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents?

Fluorochrome-conjugated monoclonal antibodies are purified, specific antibody clones covalently linked to fluorescent dyes for detecting cell surface or intracellular antigens by flow cytometry. They form the core of immunophenotyping panels from 4-color clinical tubes to 30-color research designs.

What is the Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents?

Fluorochrome-conjugated monoclonal antibodies are purified, specific antibody clones covalently linked to fluorescent dyes for detecting cell surface or intracellular antigens by flow cytometry. They form the core of immunophenotyping panels from 4-color clinical tubes to 30-color research designs.

Overview

These reagents are supplied as liquid antibody solutions, typically 0.1 to 0.5 milligrams per milliliter in a stabilizing buffer with low azide, conjugated to fluorochromes including FITC, PE, PerCP, APC, tandem dyes such as PE-Cy7 and APC-Cy7, and polymer dyes excited by violet lasers. Each antibody is defined by its clone, isotype and conjugate, and validated on human, mouse or other species cells. Pre-titrated volumes such as 5 microliters per test simplify clinical use, while research-grade vials are titrated by the user. Multi-color dried or lyophilized antibody cocktails in tubes or plates reduce pipetting error and improve reproducibility. Batch release includes conjugation ratio, specificity and staining performance. Tandem dyes are sensitive to light and fixation and can degrade, producing spillover into donor channels, so storage and handling must be carefully controlled.

How does it work?

Cytometry reagents make cellular properties detectable as optical signals. Monoclonal antibodies conjugated to fluorochromes such as FITC, PE, APC, or tandem and polymer dyes bind specific antigens, and the laser-excited fluorescence is proportional to antigen density. Nucleic acid and amine-reactive dyes discriminate live from dead cells, because membrane-compromised cells take up DNA dyes or expose more amines. Calibration and compensation beads bind antibodies through capture moieties or carry defined fluorochrome content, providing consistent positive and negative populations for compensation matrices and standardization. Fixation cross-links proteins, often with formaldehyde, while permeabilization with detergents or alcohol allows antibodies to reach intracellular or nuclear targets. Lysing solutions remove red blood cells by osmotic or ammonium-chloride lysis while preserving leukocyte scatter properties.

What are the key features?

  • Defined clone, isotype and fluorochrome conjugate for each antibody
  • Pre-titrated volumes such as 5 microliters per test for clinical workflows
  • Broad fluorochrome range from FITC to tandem and polymer dyes
  • Dried or lyophilized multi-color cocktails in tubes or plates available
  • Validated for human, mouse or other species as specified per clone
  • Batch release data for conjugation ratio, specificity and staining performance

What are the technical specifications?

A typical fluorochrome-conjugated monoclonal antibody panel reagents configuration offers antibody concentration of 0.1–0.5 mg/mL, format of Liquid; dried/lyophilized cocktails available, typical test volume of 5 µL (pre-titrated) per 10^6 cells, vial size of 0.1 mL, 0.5 mL, 2 mL, fluorochromes of FITC, PE, PerCP, APC, tandem and polymer dyes and excitation lasers of 405, 488, 561, 640 nm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents is used in lymphocyte subset immunophenotyping, leukemia and lymphoma panels, intracellular cytokine staining, stem cell CD34 enumeration and immune monitoring in clinical trials. Across the wider Cytometry Reagents class, laboratories also deploy it for immunophenotyping panels, live/dead cell discrimination and instrument compensation and QC.

Which standards and certifications apply?

Relevant standards and methods include CLSI H62, CLSI H43, ISO 20391-2, ISO 13485 (IVD reagent manufacturing), EU IVDR 2017/746 and ISAC MIFlowCyt. Certification candidates for this model are ISO 13485 manufacturing, CE-IVD marking for selected products and RUO labeling; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Store antibodies and dyes at 2 to 8 degrees Celsius, protected from light, and never freeze tandem dyes, which degrade and cause spillover. Titrate every new antibody lot, and record lot numbers in your experiment records. Use Fc receptor blocking where needed, and include fluorescence-minus-one and isotype or biological controls when setting gates. Prepare fresh formaldehyde solutions and validate fixation time for each epitope. Dispose of azide-containing buffers and lysing reagents according to local chemical regulations, as sodium azide can form explosive metal azides in plumbing. For regulated assays, source reagents with certificates of analysis, and revalidate panels when changing vendors or clones.

How do I select the right Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents?

Choose pre-titrated, multi-color cocktails for clinical or repeated standardized panels, and research-grade single conjugates when designing custom panels. Match fluorochromes to your lasers and pair bright dyes with low-density antigens. In an RFQ specify clone, conjugate, species, vial size, RUO or IVD status and batch documentation.

How does it compare with other Cytometry Reagents variants?

Choose reagents to match the instrument's lasers and filters, since fluorochromes must be excited and detected by your configuration. Assign bright fluorochromes to low-density antigens and dim ones to abundant antigens, and avoid spectral overlap between tandem dyes. Confirm antibody clone, species reactivity and validated application for flow cytometry. For intracellular or phospho targets, select compatible fixation and permeabilization buffers. Include a viability dye in every panel, and use compatible compensation beads for each fluorochrome. Check lot-to-lot consistency documentation, storage conditions at 2 to 8 degrees Celsius, expiry dating and supply of bulk or lyophilized formats for regulated assays. Titrate each antibody in your own cells to find the optimal staining concentration.

Full specifications

Full specifications
Antibody concentration0.1–0.5 mg/mL
FormatLiquid; dried/lyophilized cocktails available
Typical test volume5 µL (pre-titrated) per 10^6 cells
Vial size0.1 mL, 0.5 mL, 2 mL
FluorochromesFITC, PE, PerCP, APC, tandem and polymer dyes
Excitation lasers405, 488, 561, 640 nm
Storage temperature2–8 °C, protected from light
Shelf life12–24 months (typical)
Buffer preservativeSodium azide below 0.1% (typical)
Species reactivityHuman, mouse, rat (clone dependent)

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Lymphocyte subset immunophenotyping
  • Leukemia and lymphoma panels
  • Intracellular cytokine staining
  • Stem cell CD34 enumeration
  • Immune monitoring in clinical trials

Key features

  • Defined clone, isotype and fluorochrome conjugate for each antibody
  • Pre-titrated volumes such as 5 microliters per test for clinical workflows
  • Broad fluorochrome range from FITC to tandem and polymer dyes
  • Dried or lyophilized multi-color cocktails in tubes or plates available
  • Validated for human, mouse or other species as specified per clone
  • Batch release data for conjugation ratio, specificity and staining performance

Frequently asked questions about Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents

Research-use-only antibodies are validated for research and not cleared for diagnostic decisions. IVD antibodies are manufactured and documented under in vitro diagnostic regulations, such as IVDR in Europe, with defined performance claims. Laboratories must validate either type for their own intended use.

Red Blood Cell Lysing Reagents — product photo

Red Blood Cell Lysing Reagents

红细胞裂解试剂

  • ISO 13485 manufacturing (to be confirmed)
  • +2
Request a quote

Request a quotation for the Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote