Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents
荧光素偶联单克隆抗体检测组合试剂
- SKU CYR-0001
- Cytometry Reagents
- ISO 13485 manufacturing (to be confirmed)
- CE-IVD marking for selected products (to be confirmed)
- RUO labeling (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Antibody concentration | 0.1–0.5 mg/mL |
|---|---|
| Format | Liquid; dried/lyophilized cocktails available |
| Typical test volume | 5 µL (pre-titrated) per 10^6 cells |
| Vial size | 0.1 mL, 0.5 mL, 2 mL |
| Fluorochromes | FITC, PE, PerCP, APC, tandem and polymer dyes |
| Excitation lasers | 405, 488, 561, 640 nm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI H62, CLSI H43, ISO 20391-2
What is the Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents?
Fluorochrome-conjugated monoclonal antibodies are purified, specific antibody clones covalently linked to fluorescent dyes for detecting cell surface or intracellular antigens by flow cytometry. They form the core of immunophenotyping panels from 4-color clinical tubes to 30-color research designs.
What is the Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents?
Fluorochrome-conjugated monoclonal antibodies are purified, specific antibody clones covalently linked to fluorescent dyes for detecting cell surface or intracellular antigens by flow cytometry. They form the core of immunophenotyping panels from 4-color clinical tubes to 30-color research designs.
Overview
These reagents are supplied as liquid antibody solutions, typically 0.1 to 0.5 milligrams per milliliter in a stabilizing buffer with low azide, conjugated to fluorochromes including FITC, PE, PerCP, APC, tandem dyes such as PE-Cy7 and APC-Cy7, and polymer dyes excited by violet lasers. Each antibody is defined by its clone, isotype and conjugate, and validated on human, mouse or other species cells. Pre-titrated volumes such as 5 microliters per test simplify clinical use, while research-grade vials are titrated by the user. Multi-color dried or lyophilized antibody cocktails in tubes or plates reduce pipetting error and improve reproducibility. Batch release includes conjugation ratio, specificity and staining performance. Tandem dyes are sensitive to light and fixation and can degrade, producing spillover into donor channels, so storage and handling must be carefully controlled.
How does it work?
Cytometry reagents make cellular properties detectable as optical signals. Monoclonal antibodies conjugated to fluorochromes such as FITC, PE, APC, or tandem and polymer dyes bind specific antigens, and the laser-excited fluorescence is proportional to antigen density. Nucleic acid and amine-reactive dyes discriminate live from dead cells, because membrane-compromised cells take up DNA dyes or expose more amines. Calibration and compensation beads bind antibodies through capture moieties or carry defined fluorochrome content, providing consistent positive and negative populations for compensation matrices and standardization. Fixation cross-links proteins, often with formaldehyde, while permeabilization with detergents or alcohol allows antibodies to reach intracellular or nuclear targets. Lysing solutions remove red blood cells by osmotic or ammonium-chloride lysis while preserving leukocyte scatter properties.
What are the key features?
- Defined clone, isotype and fluorochrome conjugate for each antibody
- Pre-titrated volumes such as 5 microliters per test for clinical workflows
- Broad fluorochrome range from FITC to tandem and polymer dyes
- Dried or lyophilized multi-color cocktails in tubes or plates available
- Validated for human, mouse or other species as specified per clone
- Batch release data for conjugation ratio, specificity and staining performance
What are the technical specifications?
A typical fluorochrome-conjugated monoclonal antibody panel reagents configuration offers antibody concentration of 0.1–0.5 mg/mL, format of Liquid; dried/lyophilized cocktails available, typical test volume of 5 µL (pre-titrated) per 10^6 cells, vial size of 0.1 mL, 0.5 mL, 2 mL, fluorochromes of FITC, PE, PerCP, APC, tandem and polymer dyes and excitation lasers of 405, 488, 561, 640 nm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents is used in lymphocyte subset immunophenotyping, leukemia and lymphoma panels, intracellular cytokine staining, stem cell CD34 enumeration and immune monitoring in clinical trials. Across the wider Cytometry Reagents class, laboratories also deploy it for immunophenotyping panels, live/dead cell discrimination and instrument compensation and QC.
Which standards and certifications apply?
Relevant standards and methods include CLSI H62, CLSI H43, ISO 20391-2, ISO 13485 (IVD reagent manufacturing), EU IVDR 2017/746 and ISAC MIFlowCyt. Certification candidates for this model are ISO 13485 manufacturing, CE-IVD marking for selected products and RUO labeling; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Store antibodies and dyes at 2 to 8 degrees Celsius, protected from light, and never freeze tandem dyes, which degrade and cause spillover. Titrate every new antibody lot, and record lot numbers in your experiment records. Use Fc receptor blocking where needed, and include fluorescence-minus-one and isotype or biological controls when setting gates. Prepare fresh formaldehyde solutions and validate fixation time for each epitope. Dispose of azide-containing buffers and lysing reagents according to local chemical regulations, as sodium azide can form explosive metal azides in plumbing. For regulated assays, source reagents with certificates of analysis, and revalidate panels when changing vendors or clones.
How do I select the right Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents?
Choose pre-titrated, multi-color cocktails for clinical or repeated standardized panels, and research-grade single conjugates when designing custom panels. Match fluorochromes to your lasers and pair bright dyes with low-density antigens. In an RFQ specify clone, conjugate, species, vial size, RUO or IVD status and batch documentation.
How does it compare with other Cytometry Reagents variants?
Choose reagents to match the instrument's lasers and filters, since fluorochromes must be excited and detected by your configuration. Assign bright fluorochromes to low-density antigens and dim ones to abundant antigens, and avoid spectral overlap between tandem dyes. Confirm antibody clone, species reactivity and validated application for flow cytometry. For intracellular or phospho targets, select compatible fixation and permeabilization buffers. Include a viability dye in every panel, and use compatible compensation beads for each fluorochrome. Check lot-to-lot consistency documentation, storage conditions at 2 to 8 degrees Celsius, expiry dating and supply of bulk or lyophilized formats for regulated assays. Titrate each antibody in your own cells to find the optimal staining concentration.
Full specifications
| Antibody concentration | 0.1–0.5 mg/mL |
|---|---|
| Format | Liquid; dried/lyophilized cocktails available |
| Typical test volume | 5 µL (pre-titrated) per 10^6 cells |
| Vial size | 0.1 mL, 0.5 mL, 2 mL |
| Fluorochromes | FITC, PE, PerCP, APC, tandem and polymer dyes |
| Excitation lasers | 405, 488, 561, 640 nm |
| Storage temperature | 2–8 °C, protected from light |
| Shelf life | 12–24 months (typical) |
| Buffer preservative | Sodium azide below 0.1% (typical) |
| Species reactivity | Human, mouse, rat (clone dependent) |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Lymphocyte subset immunophenotyping
- Leukemia and lymphoma panels
- Intracellular cytokine staining
- Stem cell CD34 enumeration
- Immune monitoring in clinical trials
Key features
- Defined clone, isotype and fluorochrome conjugate for each antibody
- Pre-titrated volumes such as 5 microliters per test for clinical workflows
- Broad fluorochrome range from FITC to tandem and polymer dyes
- Dried or lyophilized multi-color cocktails in tubes or plates available
- Validated for human, mouse or other species as specified per clone
- Batch release data for conjugation ratio, specificity and staining performance
Frequently asked questions about Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents
Research-use-only antibodies are validated for research and not cleared for diagnostic decisions. IVD antibodies are manufactured and documented under in vitro diagnostic regulations, such as IVDR in Europe, with defined performance claims. Laboratories must validate either type for their own intended use.
Tandem dyes couple a donor and an acceptor fluorochrome through energy transfer. Light, fixation and time can break this link, so donor emission spills into its own channel and causes false signals. Store them at 2 to 8 degrees in the dark and use fresh compensation controls.
Pre-titrated clinical reagents typically specify 5 microliters per test for up to one million cells in 100 microliters. Research antibodies vary by clone and must be titrated; optimal amounts are often 0.06 to 1 microgram per million cells.
A typical experiment needs fluorochrome-conjugated antibodies, a viability dye, staining buffer with protein, and Fc block. Intracellular staining adds fixation and permeabilization buffers, while compensation beads, counting beads and lysing solutions support calibration, absolute counts and whole blood work.
Match each fluorochrome to your instrument's lasers and detectors, pair bright dyes with weakly expressed antigens, and minimize spectral overlap between channels. Use a spillover spreading matrix or panel design tool to check spreading error before finalizing a panel.
Too much antibody increases nonspecific binding and background, while too little reduces the signal and staining index. Titration with serial dilutions on your own cells identifies the concentration with the best separation of positive and negative populations and saves reagent.
Related models





Offline Flow Cytometry Data Analysis Software
离线流式细胞术数据分析软件
- ISO 9001 software development (to be confirmed)
- +2