Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents
荧光素偶联单克隆抗体检测组合试剂
- ISO 13485 manufacturing (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

红细胞裂解试剂
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Lysis chemistry | Ammonium chloride / lyse-fix (formaldehyde) |
|---|---|
| Working concentration | 1× (10× stock available) |
| Lysis time | 10–15 min at room temperature |
| Sample-to-lysing reagent ratio | 1:10 to 1:20 (v/v) |
| Wash step | Required (ammonium chloride) / optional (lyse-fix) |
| Post-lysis stability | Up to 24 h (lyse-fix) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI H62, CLSI H43, ISO 20391-2
Red blood cell lysing reagents selectively lyse erythrocytes in whole blood or bone marrow while preserving leukocyte scatter and antigen expression. They are used in no-wash or wash protocols for immunophenotyping, and come as ammonium chloride-based lysis buffers or fixative-containing lyse-fix formulations.
Red blood cell lysing reagents selectively lyse erythrocytes in whole blood or bone marrow while preserving leukocyte scatter and antigen expression. They are used in no-wash or wash protocols for immunophenotyping, and come as ammonium chloride-based lysis buffers or fixative-containing lyse-fix formulations.
Whole blood contains about 1,000 red blood cells per white blood cell, which would overwhelm a flow cytometer if not removed. Lysing reagents exploit differences in erythrocyte membranes: ammonium chloride based solutions, used at about 0.15 M with bicarbonate and EDTA, take advantage of the carbonic anhydrase pathway to swell and lyse erythrocytes within 10 minutes while leaving leukocytes largely intact. Lyse-fix reagents combine a mild fixative, typically formaldehyde, with a lytic agent for a single-step, no-wash procedure that stabilizes samples for up to 24 hours. Protocol choice affects lymphocyte scatter separation, leukocyte viability and loss of fragile cells such as plasma cells or blasts. Ready-to-use or 10x concentrates are available, and lysing time and temperature are critical, since over-lysis causes debris and leukocyte loss.
Cytometry reagents make cellular properties detectable as optical signals. Monoclonal antibodies conjugated to fluorochromes such as FITC, PE, APC, or tandem and polymer dyes bind specific antigens, and the laser-excited fluorescence is proportional to antigen density. Nucleic acid and amine-reactive dyes discriminate live from dead cells, because membrane-compromised cells take up DNA dyes or expose more amines. Calibration and compensation beads bind antibodies through capture moieties or carry defined fluorochrome content, providing consistent positive and negative populations for compensation matrices and standardization. Fixation cross-links proteins, often with formaldehyde, while permeabilization with detergents or alcohol allows antibodies to reach intracellular or nuclear targets. Lysing solutions remove red blood cells by osmotic or ammonium-chloride lysis while preserving leukocyte scatter properties.
A typical red blood cell lysing reagents configuration offers lysis chemistry of Ammonium chloride / lyse-fix (formaldehyde), working concentration of 1× (10× stock available), lysis time of 10–15 min at room temperature, sample-to-lysing reagent ratio of 1:10 to 1:20 (v/v), wash step of Required (ammonium chloride) / optional (lyse-fix) and post-lysis stability of Up to 24 h (lyse-fix). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Red Blood Cell Lysing Reagents is used in lymphocyte subset whole blood assays, leukemia and lymphoma immunophenotyping, CD4 and CD34 counting, bone marrow sample preparation and high-throughput no-wash staining. Across the wider Cytometry Reagents class, laboratories also deploy it for immunophenotyping panels, live/dead cell discrimination and instrument compensation and QC.
Relevant standards and methods include CLSI H62, CLSI H43, ISO 20391-2, ISO 13485 (IVD reagent manufacturing), EU IVDR 2017/746 and ISAC MIFlowCyt. Certification candidates for this model are ISO 13485 manufacturing, CE-IVD marking for selected products and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Store antibodies and dyes at 2 to 8 degrees Celsius, protected from light, and never freeze tandem dyes, which degrade and cause spillover. Titrate every new antibody lot, and record lot numbers in your experiment records. Use Fc receptor blocking where needed, and include fluorescence-minus-one and isotype or biological controls when setting gates. Prepare fresh formaldehyde solutions and validate fixation time for each epitope. Dispose of azide-containing buffers and lysing reagents according to local chemical regulations, as sodium azide can form explosive metal azides in plumbing. For regulated assays, source reagents with certificates of analysis, and revalidate panels when changing vendors or clones.
Choose ammonium chloride lysis when viable leukocytes or later functional tests are needed, and lyse-fix reagents for fast, stable no-wash clinical workflows. Fragile populations may need gentler lysing. In an RFQ, specify the concentration, specimen type, protocol (wash or no-wash), bottle size and whether IVD status is required.
Choose reagents to match the instrument's lasers and filters, since fluorochromes must be excited and detected by your configuration. Assign bright fluorochromes to low-density antigens and dim ones to abundant antigens, and avoid spectral overlap between tandem dyes. Confirm antibody clone, species reactivity and validated application for flow cytometry. For intracellular or phospho targets, select compatible fixation and permeabilization buffers. Include a viability dye in every panel, and use compatible compensation beads for each fluorochrome. Check lot-to-lot consistency documentation, storage conditions at 2 to 8 degrees Celsius, expiry dating and supply of bulk or lyophilized formats for regulated assays. Titrate each antibody in your own cells to find the optimal staining concentration.
| Lysis chemistry | Ammonium chloride / lyse-fix (formaldehyde) |
|---|---|
| Working concentration | 1× (10× stock available) |
| Lysis time | 10–15 min at room temperature |
| Sample-to-lysing reagent ratio | 1:10 to 1:20 (v/v) |
| Wash step | Required (ammonium chloride) / optional (lyse-fix) |
| Post-lysis stability | Up to 24 h (lyse-fix) |
| Bottle size | 100 mL, 500 mL, 1 L |
| Suitable specimens | Whole blood, bone marrow, cord blood |
| Storage temperature | 15–25 °C (2–8 °C for some lyse-fix) |
| Shelf life | 12–24 months |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
A lysing reagent such as ammonium chloride removes red blood cells but does not fix leukocytes, so samples are processed promptly. A lyse-fix reagent adds a fixative to stabilize leukocytes in one step, allowing delayed acquisition for up to about 24 hours.
Yes, bone marrow contains fewer red cells but the same reagents are used, often with adjusted volumes and lysing time. Fragile blasts and plasma cells can be lost by harsh lysis, so gentler protocols or density separation may be preferred.
Over-lysis shrinks or damages leukocytes, reducing viability and altering forward and side scatter, which can blur lymphocyte, monocyte and granulocyte gates. It also increases debris, so follow the recommended time and temperature closely.
A typical experiment needs fluorochrome-conjugated antibodies, a viability dye, staining buffer with protein, and Fc block. Intracellular staining adds fixation and permeabilization buffers, while compensation beads, counting beads and lysing solutions support calibration, absolute counts and whole blood work.
Match each fluorochrome to your instrument's lasers and detectors, pair bright dyes with weakly expressed antigens, and minimize spectral overlap between channels. Use a spillover spreading matrix or panel design tool to check spreading error before finalizing a panel.
Too much antibody increases nonspecific binding and background, while too little reduces the signal and staining index. Titration with serial dilutions on your own cells identifies the concentration with the best separation of positive and negative populations and saves reagent.