Fluorochrome-Conjugated Monoclonal Antibody Panel Reagents
荧光素偶联单克隆抗体检测组合试剂
- ISO 13485 manufacturing (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

固定与破膜缓冲液试剂
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Fixative | Formaldehyde 1–4% (working) |
|---|---|
| Permeabilization agent | Saponin 0.1–0.5%, Triton X-100, or methanol ≥90% |
| Fixation time | 10–30 min at room temperature or 2–8 °C |
| Permeabilization time | 10–30 min (methanol: 30 min at −20 °C) |
| Format | Liquid concentrate (5–10×) or ready-to-use |
| Kit size | 100–1,000 tests |
By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI H62, CLSI H43, ISO 20391-2
Fixation and permeabilization buffer reagents preserve cell structure and open membranes so antibodies can reach intracellular, cytoplasmic or nuclear antigens. Formaldehyde-based fixatives combine with saponin, detergent or methanol permeabilization, and are used for cytokines, transcription factors and phospho-proteins in immunology and signaling research.
Fixation and permeabilization buffer reagents preserve cell structure and open membranes so antibodies can reach intracellular, cytoplasmic or nuclear antigens. Formaldehyde-based fixatives combine with saponin, detergent or methanol permeabilization, and are used for cytokines, transcription factors and phospho-proteins in immunology and signaling research.
Fixation stabilizes cell morphology and antigen location, most commonly with 1 to 4 percent formaldehyde, which cross-links proteins within minutes at room temperature. Permeabilization then creates pores for antibody access. Mild detergents such as saponin, used at about 0.1 to 0.5 percent, create reversible pores and suit cytoplasmic cytokines and require continuous presence in wash buffers. Stronger permeabilization with Triton X-100, Tween-20 or methanol of at least 90 percent, often at minus 20 degrees, is needed for nuclear antigens and phospho-epitopes. Commercial kits supply matched fixation and permeabilization buffers, sometimes with a single-step fixation and permeabilization concentrate for transcription factors such as FoxP3. Choice of method affects epitope availability and fluorochrome stability, for instance methanol can damage PE and tandem dyes, so the order of surface and intracellular staining must be validated.
Cytometry reagents make cellular properties detectable as optical signals. Monoclonal antibodies conjugated to fluorochromes such as FITC, PE, APC, or tandem and polymer dyes bind specific antigens, and the laser-excited fluorescence is proportional to antigen density. Nucleic acid and amine-reactive dyes discriminate live from dead cells, because membrane-compromised cells take up DNA dyes or expose more amines. Calibration and compensation beads bind antibodies through capture moieties or carry defined fluorochrome content, providing consistent positive and negative populations for compensation matrices and standardization. Fixation cross-links proteins, often with formaldehyde, while permeabilization with detergents or alcohol allows antibodies to reach intracellular or nuclear targets. Lysing solutions remove red blood cells by osmotic or ammonium-chloride lysis while preserving leukocyte scatter properties.
A typical fixation and permeabilization buffer reagents configuration offers fixative of Formaldehyde 1–4% (working), permeabilization agent of Saponin 0.1–0.5%, Triton X-100, or methanol ≥90%, fixation time of 10–30 min at room temperature or 2–8 °C, permeabilization time of 10–30 min (methanol: 30 min at −20 °C), format of Liquid concentrate (5–10×) or ready-to-use and kit size of 100–1,000 tests. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Fixation and Permeabilization Buffer Reagents is used in intracellular cytokine staining, foxP3 and transcription factor detection, phospho-protein signaling analysis, cell cycle DNA content staining and long-term sample preservation before acquisition. Across the wider Cytometry Reagents class, laboratories also deploy it for immunophenotyping panels, live/dead cell discrimination and instrument compensation and QC.
Relevant standards and methods include CLSI H62, CLSI H43, ISO 20391-2, ISO 13485 (IVD reagent manufacturing), EU IVDR 2017/746 and ISAC MIFlowCyt. Certification candidates for this model are ISO 9001 manufacturing, RUO labeling and REACH compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Store antibodies and dyes at 2 to 8 degrees Celsius, protected from light, and never freeze tandem dyes, which degrade and cause spillover. Titrate every new antibody lot, and record lot numbers in your experiment records. Use Fc receptor blocking where needed, and include fluorescence-minus-one and isotype or biological controls when setting gates. Prepare fresh formaldehyde solutions and validate fixation time for each epitope. Dispose of azide-containing buffers and lysing reagents according to local chemical regulations, as sodium azide can form explosive metal azides in plumbing. For regulated assays, source reagents with certificates of analysis, and revalidate panels when changing vendors or clones.
Choose saponin-based kits for cytoplasmic cytokines, stronger detergent or methanol methods for nuclear and phospho targets, and matched one-step kits for transcription factors. Verify fluorochrome compatibility since methanol degrades some conjugates. In an RFQ, specify the target type, buffer format, number of tests per kit and storage temperature.
Choose reagents to match the instrument's lasers and filters, since fluorochromes must be excited and detected by your configuration. Assign bright fluorochromes to low-density antigens and dim ones to abundant antigens, and avoid spectral overlap between tandem dyes. Confirm antibody clone, species reactivity and validated application for flow cytometry. For intracellular or phospho targets, select compatible fixation and permeabilization buffers. Include a viability dye in every panel, and use compatible compensation beads for each fluorochrome. Check lot-to-lot consistency documentation, storage conditions at 2 to 8 degrees Celsius, expiry dating and supply of bulk or lyophilized formats for regulated assays. Titrate each antibody in your own cells to find the optimal staining concentration.
| Fixative | Formaldehyde 1–4% (working) |
|---|---|
| Permeabilization agent | Saponin 0.1–0.5%, Triton X-100, or methanol ≥90% |
| Fixation time | 10–30 min at room temperature or 2–8 °C |
| Permeabilization time | 10–30 min (methanol: 30 min at −20 °C) |
| Format | Liquid concentrate (5–10×) or ready-to-use |
| Kit size | 100–1,000 tests |
| Target compartments | Cytoplasmic, nuclear, phospho-epitopes |
| Storage temperature | 2–8 °C (methanol at −20 °C) |
| pH | 7.2–7.4 (buffered solutions) |
| Shelf life | 12–24 months |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Fixation cross-links or precipitates proteins to preserve cell structure and antigen position, typically using formaldehyde. Permeabilization then creates pores in the membrane so large antibody molecules can enter the cell and reach intracellular or nuclear targets.
Usually before, because fixation and permeabilization can alter some surface epitopes and damage tandem dyes. Stain surface markers and viability first, then fix and permeabilize for intracellular targets, and validate each antibody clone for this order.
Cold methanol strongly permeabilizes cells and exposes phospho-epitopes and nuclear antigens that milder detergents cannot reach. It also precipitates proteins, so some surface epitopes and fluorochromes such as PE are damaged and need validation.
A typical experiment needs fluorochrome-conjugated antibodies, a viability dye, staining buffer with protein, and Fc block. Intracellular staining adds fixation and permeabilization buffers, while compensation beads, counting beads and lysing solutions support calibration, absolute counts and whole blood work.
Match each fluorochrome to your instrument's lasers and detectors, pair bright dyes with weakly expressed antigens, and minimize spectral overlap between channels. Use a spillover spreading matrix or panel design tool to check spreading error before finalizing a panel.
Too much antibody increases nonspecific binding and background, while too little reduces the signal and staining index. Titration with serial dilutions on your own cells identifies the concentration with the best separation of positive and negative populations and saves reagent.

荧光素偶联单克隆抗体检测组合试剂




云端流式细胞术数据管理平台