Flow Cytometer Acquisition and Control Software — product photo

Flow Cytometer Acquisition and Control Software

流式细胞仪采集与控制软件

  • SKU CYS-0001
  • Cytometry Software
  • ISO 13485 software lifecycle (to be confirmed)
  • IEC 62304 software process (to be confirmed)
  • CE (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Operating systemWindows 10/11 (64-bit)
Output formatFCS 3.1
Instrument couplingModel-specific
Maximum parametersUp to 60+ (model dependent)
Maximum acquisition rate supportedUp to 100,000 events/s (instrument limited)
QC moduleBead-based with Levey-Jennings tracking
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISAC FCS 3.1 data standard, ISAC FCS 3.2 data standard, ISAC MIFlowCyt

What is the Flow Cytometer Acquisition and Control Software?

Flow cytometer acquisition and control software operates the instrument, sets detector voltages and thresholds, runs quality control and writes list-mode FCS files during data collection. It is tied to a specific cytometer model and is the first software layer needed on any new instrument workstation.

What is the Flow Cytometer Acquisition and Control Software?

Flow cytometer acquisition and control software operates the instrument, sets detector voltages and thresholds, runs quality control and writes list-mode FCS files during data collection. It is tied to a specific cytometer model and is the first software layer needed on any new instrument workstation.

Overview

Acquisition software provides the operator interface for startup, fluidics control, laser and detector configuration, and data recording. Users define experiment templates with parameter lists, voltage or gain settings, thresholds, stop conditions and plot layouts. Daily quality control modules run calibration beads and track performance in Levey-Jennings charts, flagging deviations in sensitivity, CV or laser delay. During acquisition, real-time plots and gating support setting sort gates and verifying compensation, and an automated compensation setup uses single-stain controls to calculate matrices. Data are stored in FCS 3.1 files with experiment metadata, and export tools transfer them to network storage. User accounts with permission levels restrict who can change instrument settings. The software runs on a validated Windows workstation supplied with the instrument, and firmware and software updates must match the hardware.

How does it work?

Cytometry software handles three stages. During acquisition it configures detector voltages, thresholds and gains, triggers on defined parameters, and writes each event's scatter and fluorescence values to list-mode FCS files with metadata. Analysis software then applies compensation or spectral unmixing to correct spillover, transforms data with logicle or biexponential scales to display negative values, and lets users draw hierarchical gates on histograms and dot plots to define populations. It calculates statistics such as percent parent, median fluorescence intensity and coefficient of variation. High-dimensional tools add dimensionality reduction with tSNE or UMAP and unsupervised clustering with algorithms such as FlowSOM or PhenoGraph. Regulated platforms add user authentication, audit trails, electronic signatures and validated templates.

What are the key features?

  • Experiment templates store parameters, voltages, thresholds and plot layouts
  • Daily QC module tracks bead performance in Levey-Jennings charts
  • Automated compensation setup calculates matrices from single-stain controls
  • Real-time plots and gating during acquisition and sorting
  • FCS 3.1 output with experiment and instrument metadata
  • User accounts with permission levels restrict instrument setting changes

What are the technical specifications?

A typical flow cytometer acquisition and control software configuration offers operating system of Windows 10/11 (64-bit), output format of FCS 3.1, instrument coupling of Model-specific, maximum parameters of Up to 60+ (model dependent), maximum acquisition rate supported of Up to 100,000 events/s (instrument limited) and QC module of Bead-based with Levey-Jennings tracking. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Flow Cytometer Acquisition and Control Software is used in daily instrument startup and QC, panel acquisition with templates, cell sorting control, plate and tube loader runs and multi-user core facility operation. Across the wider Cytometry Software class, laboratories also deploy it for instrument acquisition and quality control, offline flow data analysis and reporting and high-dimensional immune profiling.

Which standards and certifications apply?

Relevant standards and methods include ISAC FCS 3.1 data standard, ISAC FCS 3.2 data standard, ISAC MIFlowCyt, 21 CFR Part 11, EU GMP Annex 11, GAMP 5 and CLSI H62. Certification candidates for this model are ISO 13485 software lifecycle, IEC 62304 software process and CE; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install acquisition software only on the validated workstation supplied or approved for the cytometer, with operating system updates under change control. Back up FCS data to network storage on a schedule and follow the MIFlowCyt guideline to record experiment metadata for reproducibility. Validate compensation matrices with single-stain controls and review gating strategies with fluorescence-minus-one controls. Standardize gating templates across users to reduce analyst variability. For regulated work, perform installation, operational and performance qualification, lock methods and templates, and review audit trails periodically. Keep license keys and software versions documented, and confirm that exported data remain readable in future software releases.

How do I select the right Flow Cytometer Acquisition and Control Software?

Acquisition software is chosen with the cytometer, not independently, so confirm the version, licensing and upgrade path for your model. Request validation documentation if the lab is regulated. In an RFQ specify operating system, user management, QC features, loader support, data export formats and support terms.

How does it compare with other Cytometry Software variants?

Select software according to the task and the regulatory environment. Confirm instrument compatibility first, since acquisition software is tied to a specific cytometer and firmware. For analysis, verify support for FCS 2.0, 3.0, 3.1 and 3.2 files, compensation and unmixing matrices, batch processing and export of publication-quality graphs. For high-dimensional work, check for built-in tSNE, UMAP, FlowSOM and integration with R or Python. Regulated laboratories need 21 CFR Part 11 or equivalent functionality, meaning audit trails, electronic signatures, role-based access and validation documentation. Consider licensing model, including perpetual, subscription, floating or site licenses, data storage and cloud options, operating system support, and whether technical support and training are available locally.

Full specifications

Full specifications
Operating systemWindows 10/11 (64-bit)
Output formatFCS 3.1
Instrument couplingModel-specific
Maximum parametersUp to 60+ (model dependent)
Maximum acquisition rate supportedUp to 100,000 events/s (instrument limited)
QC moduleBead-based with Levey-Jennings tracking
CompensationAutomated and manual matrix
User managementRole-based accounts and passwords
Data exportFCS, CSV, PDF reports
Workstation RAM16 GB or more

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Daily instrument startup and QC
  • Panel acquisition with templates
  • Cell sorting control
  • Plate and tube loader runs
  • Multi-user core facility operation

Key features

  • Experiment templates store parameters, voltages, thresholds and plot layouts
  • Daily QC module tracks bead performance in Levey-Jennings charts
  • Automated compensation setup calculates matrices from single-stain controls
  • Real-time plots and gating during acquisition and sorting
  • FCS 3.1 output with experiment and instrument metadata
  • User accounts with permission levels restrict instrument setting changes

Frequently asked questions about Flow Cytometer Acquisition and Control Software

Generally no. It must run on the validated workstation and operating system specified for the cytometer, because it communicates with instrument electronics through dedicated interfaces. Unapproved hardware or updates can cause communication errors and invalidate support.

Request a quotation for the Flow Cytometer Acquisition and Control Software

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.