Skip to main content
Lab Manufacturers China
21 CFR Part 11 Compliant Clinical Flow Cytometry Software — product photo

21 CFR Part 11 Compliant Clinical Flow Cytometry Software

符合 21 CFR Part 11 的临床流式细胞术软件

  • SKU CYS-0004
  • Cytometry Software
  • ISO 13485 software lifecycle (to be confirmed)
  • IEC 62304 software process (to be confirmed)
  • GAMP 5 validation documentation (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Regulatory frameworks21 CFR Part 11, EU GMP Annex 11
Access controlRole-based, unique user IDs
Audit trailTime-stamped, non-editable
Electronic signatureTwo-component (ID and password)
Template lockingApproved assay templates
Data storageSecure database with backup
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISAC FCS 3.1 data standard, ISAC FCS 3.2 data standard, ISAC MIFlowCyt

What is the 21 CFR Part 11 Compliant Clinical Flow Cytometry Software?

Part 11 compliant clinical flow cytometry software adds user authentication, audit trails, electronic signatures and locked templates to acquisition and analysis so that data integrity requirements are met. It is used in GMP, GLP and clinical laboratories where electronic records support regulated decisions.

What is the 21 CFR Part 11 Compliant Clinical Flow Cytometry Software?

Part 11 compliant clinical flow cytometry software adds user authentication, audit trails, electronic signatures and locked templates to acquisition and analysis so that data integrity requirements are met. It is used in GMP, GLP and clinical laboratories where electronic records support regulated decisions.

Overview

Regulated flow cytometry software implements technical controls described in 21 CFR Part 11 and EU GMP Annex 11. Individual user accounts with role-based permissions and password policies control access, and every action affecting data, such as creating, modifying or deleting gates, is recorded in a secure, time-stamped audit trail that cannot be edited. Electronic signatures are linked to records with meaning such as review or approval. Validated assay templates lock acquisition settings, compensation and gating strategies, so that analysts cannot change them without documented change control. Data are stored in secure databases with backup and archiving. Vendors usually supply validation documentation, including IQ and OQ protocols, and support with GAMP 5 risk-based validation. The laboratory remains responsible for procedures, training and periodic audit trail review.

How does it work?

Cytometry software handles three stages. During acquisition it configures detector voltages, thresholds and gains, triggers on defined parameters, and writes each event's scatter and fluorescence values to list-mode FCS files with metadata. Analysis software then applies compensation or spectral unmixing to correct spillover, transforms data with logicle or biexponential scales to display negative values, and lets users draw hierarchical gates on histograms and dot plots to define populations. It calculates statistics such as percent parent, median fluorescence intensity and coefficient of variation. High-dimensional tools add dimensionality reduction with tSNE or UMAP and unsupervised clustering with algorithms such as FlowSOM or PhenoGraph. Regulated platforms add user authentication, audit trails, electronic signatures and validated templates.

What are the key features?

  • Role-based user accounts with password policy and account lockout
  • Time-stamped audit trail records creation, modification and deletion of data
  • Electronic signatures linked to records with review or approval meaning
  • Locked assay templates protect acquisition settings and gating strategies
  • Secure database storage with backup and archive functions
  • Vendor validation package with IQ and OQ protocols

What are the technical specifications?

A typical 21 cfr part 11 compliant clinical flow cytometry software configuration offers regulatory frameworks of 21 CFR Part 11, EU GMP Annex 11, access control of Role-based, unique user IDs, audit trail of Time-stamped, non-editable, electronic signature of Two-component (ID and password), template locking of Approved assay templates and data storage of Secure database with backup. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The 21 CFR Part 11 Compliant Clinical Flow Cytometry Software is used in GMP release testing of cell therapies, clinical trial central laboratory flow testing, clinical immunophenotyping reporting, GLP preclinical studies and quality control of biopharmaceutical cell products. Across the wider Cytometry Software class, laboratories also deploy it for instrument acquisition and quality control, offline flow data analysis and reporting and high-dimensional immune profiling.

Which standards and certifications apply?

Relevant standards and methods include ISAC FCS 3.1 data standard, ISAC FCS 3.2 data standard, ISAC MIFlowCyt, 21 CFR Part 11, EU GMP Annex 11, GAMP 5 and CLSI H62. Certification candidates for this model are ISO 13485 software lifecycle, IEC 62304 software process and GAMP 5 validation documentation; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install acquisition software only on the validated workstation supplied or approved for the cytometer, with operating system updates under change control. Back up FCS data to network storage on a schedule and follow the MIFlowCyt guideline to record experiment metadata for reproducibility. Validate compensation matrices with single-stain controls and review gating strategies with fluorescence-minus-one controls. Standardize gating templates across users to reduce analyst variability. For regulated work, perform installation, operational and performance qualification, lock methods and templates, and review audit trails periodically. Keep license keys and software versions documented, and confirm that exported data remain readable in future software releases.

How do I select the right 21 CFR Part 11 Compliant Clinical Flow Cytometry Software?

Choose Part 11 capable software when flow data support regulatory submissions, release testing or accredited clinical reporting. It adds license cost and administration, so research-only labs may not need it. In an RFQ specify audit trail features, signature meanings, validation package, LIMS integration and support.

How does it compare with other Cytometry Software variants?

Select software according to the task and the regulatory environment. Confirm instrument compatibility first, since acquisition software is tied to a specific cytometer and firmware. For analysis, verify support for FCS 2.0, 3.0, 3.1 and 3.2 files, compensation and unmixing matrices, batch processing and export of publication-quality graphs. For high-dimensional work, check for built-in tSNE, UMAP, FlowSOM and integration with R or Python. Regulated laboratories need 21 CFR Part 11 or equivalent functionality, meaning audit trails, electronic signatures, role-based access and validation documentation. Consider licensing model, including perpetual, subscription, floating or site licenses, data storage and cloud options, operating system support, and whether technical support and training are available locally.

Full specifications

Full specifications
Regulatory frameworks21 CFR Part 11, EU GMP Annex 11
Access controlRole-based, unique user IDs
Audit trailTime-stamped, non-editable
Electronic signatureTwo-component (ID and password)
Template lockingApproved assay templates
Data storageSecure database with backup
Validation documentationIQ/OQ protocols, traceability matrix
LIS/LIMS integrationHL7 or ASTM interface (optional)
Operating systemWindows 10/11, Windows Server
Report outputSigned PDF reports

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • GMP release testing of cell therapies
  • Clinical trial central laboratory flow testing
  • Clinical immunophenotyping reporting
  • GLP preclinical studies
  • Quality control of biopharmaceutical cell products

Key features

  • Role-based user accounts with password policy and account lockout
  • Time-stamped audit trail records creation, modification and deletion of data
  • Electronic signatures linked to records with review or approval meaning
  • Locked assay templates protect acquisition settings and gating strategies
  • Secure database storage with backup and archive functions
  • Vendor validation package with IQ and OQ protocols

Frequently asked questions about 21 CFR Part 11 Compliant Clinical Flow Cytometry Software

No. Software provides technical controls such as audit trails and electronic signatures, but compliance also depends on laboratory procedures, training, validation and periodic review. Both the vendor and the user share responsibility for maintaining the validated state.

Red Blood Cell Lysing Reagents — product photo

Red Blood Cell Lysing Reagents

红细胞裂解试剂

  • ISO 13485 manufacturing (to be confirmed)
  • +2
Request a quote

Request a quotation for the 21 CFR Part 11 Compliant Clinical Flow Cytometry Software

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote