Flow Cytometer Acquisition and Control Software
流式细胞仪采集与控制软件
- ISO 13485 software lifecycle (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

符合 21 CFR Part 11 的临床流式细胞术软件
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Regulatory frameworks | 21 CFR Part 11, EU GMP Annex 11 |
|---|---|
| Access control | Role-based, unique user IDs |
| Audit trail | Time-stamped, non-editable |
| Electronic signature | Two-component (ID and password) |
| Template locking | Approved assay templates |
| Data storage | Secure database with backup |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISAC FCS 3.1 data standard, ISAC FCS 3.2 data standard, ISAC MIFlowCyt
Part 11 compliant clinical flow cytometry software adds user authentication, audit trails, electronic signatures and locked templates to acquisition and analysis so that data integrity requirements are met. It is used in GMP, GLP and clinical laboratories where electronic records support regulated decisions.
Part 11 compliant clinical flow cytometry software adds user authentication, audit trails, electronic signatures and locked templates to acquisition and analysis so that data integrity requirements are met. It is used in GMP, GLP and clinical laboratories where electronic records support regulated decisions.
Regulated flow cytometry software implements technical controls described in 21 CFR Part 11 and EU GMP Annex 11. Individual user accounts with role-based permissions and password policies control access, and every action affecting data, such as creating, modifying or deleting gates, is recorded in a secure, time-stamped audit trail that cannot be edited. Electronic signatures are linked to records with meaning such as review or approval. Validated assay templates lock acquisition settings, compensation and gating strategies, so that analysts cannot change them without documented change control. Data are stored in secure databases with backup and archiving. Vendors usually supply validation documentation, including IQ and OQ protocols, and support with GAMP 5 risk-based validation. The laboratory remains responsible for procedures, training and periodic audit trail review.
Cytometry software handles three stages. During acquisition it configures detector voltages, thresholds and gains, triggers on defined parameters, and writes each event's scatter and fluorescence values to list-mode FCS files with metadata. Analysis software then applies compensation or spectral unmixing to correct spillover, transforms data with logicle or biexponential scales to display negative values, and lets users draw hierarchical gates on histograms and dot plots to define populations. It calculates statistics such as percent parent, median fluorescence intensity and coefficient of variation. High-dimensional tools add dimensionality reduction with tSNE or UMAP and unsupervised clustering with algorithms such as FlowSOM or PhenoGraph. Regulated platforms add user authentication, audit trails, electronic signatures and validated templates.
A typical 21 cfr part 11 compliant clinical flow cytometry software configuration offers regulatory frameworks of 21 CFR Part 11, EU GMP Annex 11, access control of Role-based, unique user IDs, audit trail of Time-stamped, non-editable, electronic signature of Two-component (ID and password), template locking of Approved assay templates and data storage of Secure database with backup. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The 21 CFR Part 11 Compliant Clinical Flow Cytometry Software is used in GMP release testing of cell therapies, clinical trial central laboratory flow testing, clinical immunophenotyping reporting, GLP preclinical studies and quality control of biopharmaceutical cell products. Across the wider Cytometry Software class, laboratories also deploy it for instrument acquisition and quality control, offline flow data analysis and reporting and high-dimensional immune profiling.
Relevant standards and methods include ISAC FCS 3.1 data standard, ISAC FCS 3.2 data standard, ISAC MIFlowCyt, 21 CFR Part 11, EU GMP Annex 11, GAMP 5 and CLSI H62. Certification candidates for this model are ISO 13485 software lifecycle, IEC 62304 software process and GAMP 5 validation documentation; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install acquisition software only on the validated workstation supplied or approved for the cytometer, with operating system updates under change control. Back up FCS data to network storage on a schedule and follow the MIFlowCyt guideline to record experiment metadata for reproducibility. Validate compensation matrices with single-stain controls and review gating strategies with fluorescence-minus-one controls. Standardize gating templates across users to reduce analyst variability. For regulated work, perform installation, operational and performance qualification, lock methods and templates, and review audit trails periodically. Keep license keys and software versions documented, and confirm that exported data remain readable in future software releases.
Choose Part 11 capable software when flow data support regulatory submissions, release testing or accredited clinical reporting. It adds license cost and administration, so research-only labs may not need it. In an RFQ specify audit trail features, signature meanings, validation package, LIMS integration and support.
Select software according to the task and the regulatory environment. Confirm instrument compatibility first, since acquisition software is tied to a specific cytometer and firmware. For analysis, verify support for FCS 2.0, 3.0, 3.1 and 3.2 files, compensation and unmixing matrices, batch processing and export of publication-quality graphs. For high-dimensional work, check for built-in tSNE, UMAP, FlowSOM and integration with R or Python. Regulated laboratories need 21 CFR Part 11 or equivalent functionality, meaning audit trails, electronic signatures, role-based access and validation documentation. Consider licensing model, including perpetual, subscription, floating or site licenses, data storage and cloud options, operating system support, and whether technical support and training are available locally.
| Regulatory frameworks | 21 CFR Part 11, EU GMP Annex 11 |
|---|---|
| Access control | Role-based, unique user IDs |
| Audit trail | Time-stamped, non-editable |
| Electronic signature | Two-component (ID and password) |
| Template locking | Approved assay templates |
| Data storage | Secure database with backup |
| Validation documentation | IQ/OQ protocols, traceability matrix |
| LIS/LIMS integration | HL7 or ASTM interface (optional) |
| Operating system | Windows 10/11, Windows Server |
| Report output | Signed PDF reports |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
No. Software provides technical controls such as audit trails and electronic signatures, but compliance also depends on laboratory procedures, training, validation and periodic review. Both the vendor and the user share responsibility for maintaining the validated state.
An audit trail is a secure, time-stamped log that records who created, changed or deleted data and gating, with old and new values and the reason for change. It cannot be edited by users and is reviewed during audits.
Often yes, through an upgraded software version or a compliance module installed on the acquisition workstation. Feasibility depends on instrument model and firmware, so the vendor must confirm compatibility and supply validation documentation.
It controls the instrument during acquisition, records each event to FCS files, and then supports analysis by compensation, gating, statistics and plotting. Advanced software adds dimensionality reduction, clustering and batch processing, and regulated packages add audit trails and electronic signatures.
FCS is the Flow Cytometry Standard defined by the International Society for Advancement of Cytometry. It stores list-mode event data and metadata such as parameters, voltages and compensation in a single file, with versions 3.0, 3.1 and 3.2 in current use.
You need it when electronic records support regulated decisions, such as GMP release testing or clinical trial submissions to the FDA. Compliance requires audit trails, electronic signatures, access control and validation, and the lab's procedures must also support these controls.