Skip to main content
Lab Manufacturers China
Indoor Air Quality Monitor for CO2, VOC and Formaldehyde — product photo

Indoor Air Quality Monitor for CO2, VOC and Formaldehyde

室内空气质量监测仪(CO2、VOC 和甲醛)

  • SKU AIM-0005
  • Air Monitoring
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • China MC metrology approval (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
CO2 range0–5000 ppm, ±(50 ppm + 3%)
Formaldehyde range0–5 ppm, 0.01 ppm resolution
TVOC range0–10 ppm isobutylene equivalent
PM2.5 range0–1000 µg/m³
Temperature range−10 to 60 °C, ±0.5 °C
Humidity range0–100% RH, ±3% RH
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 12341, EN 14211, EN 14212

What is the Indoor Air Quality Monitor for CO2, VOC and Formaldehyde?

A handheld or wall-mounted monitor that measures carbon dioxide, total VOC, formaldehyde, particulates, temperature and humidity in occupied spaces. It is the right choice for ventilation assessment, building commissioning and complaint investigation in offices, schools and homes.

What is the Indoor Air Quality Monitor for CO2, VOC and Formaldehyde?

A handheld or wall-mounted monitor that measures carbon dioxide, total VOC, formaldehyde, particulates, temperature and humidity in occupied spaces. It is the right choice for ventilation assessment, building commissioning and complaint investigation in offices, schools and homes.

Overview

This multi-sensor instrument combines non-dispersive infrared CO2 detection, metal oxide or photoionization VOC sensing, electrochemical formaldehyde detection and laser PM2.5 into one device. CO2 values near 400 ppm indicate outdoor-level ventilation, while sustained readings above 1000 ppm suggest inadequate fresh air. Formaldehyde sensors cover 0 to 5 ppm with resolution of 0.01 ppm to check furniture and renovation emissions against guideline limits such as 0.08 mg/m³ in GB/T 18883. Data logging with time stamps enables occupancy-correlated analysis, and the device can export to spreadsheets or integrate into building management systems via BACnet or Modbus. Handheld units offer quick surveys, and fixed units support continuous ventilation control.

How does it work?

Air monitors sample air through an inlet and quantify target components by physical or chemical sensing. Particulate instruments use laser light scattering, beta ray attenuation or gravimetric collection on filters, often after a size-selective inlet such as a PM2.5 impactor. Gas sensing uses electrochemical cells, metal oxide semiconductors, non-dispersive infrared absorption, photoionization, or ultraviolet and chemiluminescence analyzers for reference-grade measurements. Active samplers draw air at a controlled flow, for example 16.7 L/min for PM filters or 0.1 to 1 L/min for sorbent tubes and impingers, while passive samplers rely on diffusion. Meteorological sensors record wind, temperature, humidity and pressure to interpret results. A controller logs data, applies calibration factors and communicates over wireless networks.

What are the key features?

  • NDIR CO2 sensor provides stable readings for ventilation assessment without frequent calibration.
  • Formaldehyde module measures to 0.01 ppm resolution for renovation emission checks.
  • TVOC sensor with photoionization option responds to a broad range of solvents.
  • Integrated PM2.5, temperature and humidity give a full comfort and exposure picture.
  • Data logging with time stamps supports occupancy-correlated ventilation analysis.
  • BACnet or Modbus output connects fixed units to building management systems.

What are the technical specifications?

A typical indoor air quality monitor for co2, voc and formaldehyde configuration offers CO2 range of 0–5000 ppm, ±(50 ppm + 3%), formaldehyde range of 0–5 ppm, 0.01 ppm resolution, TVOC range of 0–10 ppm isobutylene equivalent, PM2.5 range of 0–1000 µg/m³, temperature range of −10 to 60 °C, ±0.5 °C and humidity range of 0–100% RH, ±3% RH. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Indoor Air Quality Monitor for CO2, VOC and Formaldehyde is used in office and school ventilation checks, renovation emission screening, building commissioning and indoor air complaint investigation. Across the wider Air Monitoring class, laboratories also deploy it for regional air quality networks, indoor air quality assessment and occupational exposure monitoring.

Which standards and certifications apply?

Relevant standards and methods include EN 12341, EN 14211, EN 14212, EN 14625, EN 14626, ISO 7708, US EPA 40 CFR Part 50 and HJ 653. Certification candidates for this model are CE, RoHS and China MC metrology approval; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Site the inlet away from local sources and obstructions, typically 1.5 to 15 m above ground with a clear airflow, following regulatory siting criteria. Use inert sampling lines such as PTFE for reactive gases and keep them short. Calibrate gas analyzers with certified standards and zero air, and verify flow rates on samplers with a traceable flow meter. Replace filters, pump diaphragms and sensor cells on schedule, and protect instruments from condensation and extreme temperatures with shelters or enclosures. Sensor-based devices drift with humidity and temperature, so collocate with a reference periodically. Document all events, because flagged data is required for validation and for any compliance reporting.

How do I select the right Indoor Air Quality Monitor for CO2, VOC and Formaldehyde?

Select this monitor for routine ventilation and comfort assessment, not for legally defensible compound-specific measurements. Electrochemical formaldehyde cells drift and cross-react, so confirm high readings with a DNPH sampler and HPLC. In an RFQ, list parameters, handheld or fixed format, logging needs and building system protocol.

How does it compare with other Air Monitoring variants?

Define the pollutants, the required accuracy and the decision the data supports. Regulatory networks need reference or equivalent analyzers, while screening, mapping and community monitoring can use sensor-based units with periodic collocation. For exposure assessment of workers, personal pumps with sorbent tubes or filters are required. Indoor air quality investigations usually use handheld instruments for CO2, temperature, humidity, VOC and particulates. Check range, detection limit, response time, humidity compensation and operating temperature. Consider calibration effort, consumables, power availability and communication. For mobile surveys, consider battery life, GPS and weight. Confirm that the supplier provides calibration certificates and data formats compatible with your reporting platform.

Full specifications

Full specifications
CO2 range0–5000 ppm, ±(50 ppm + 3%)
Formaldehyde range0–5 ppm, 0.01 ppm resolution
TVOC range0–10 ppm isobutylene equivalent
PM2.5 range0–1000 µg/m³
Temperature range−10 to 60 °C, ±0.5 °C
Humidity range0–100% RH, ±3% RH
Data loggingUp to 100,000 records
DisplayColor TFT or e-paper
BatteryRechargeable Li-ion, 8–24 h
CommunicationUSB, Wi-Fi, Bluetooth, optional BACnet/Modbus

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Office and school ventilation checks
  • Renovation emission screening
  • Building commissioning
  • Indoor air complaint investigation

Key features

  • NDIR CO2 sensor provides stable readings for ventilation assessment without frequent calibration.
  • Formaldehyde module measures to 0.01 ppm resolution for renovation emission checks.
  • TVOC sensor with photoionization option responds to a broad range of solvents.
  • Integrated PM2.5, temperature and humidity give a full comfort and exposure picture.
  • Data logging with time stamps supports occupancy-correlated ventilation analysis.
  • BACnet or Modbus output connects fixed units to building management systems.

Frequently asked questions about Indoor Air Quality Monitor for CO2, VOC and Formaldehyde

Outdoor air is about 420 ppm. Indoors, sustained levels above 1000 ppm suggest inadequate ventilation per ASHRAE guidance, and above 1500 to 2000 ppm are associated with drowsiness and reduced concentration. Elevated readings indicate occupancy exceeding ventilation capacity.

Related models

All Air Monitoring

Request a quotation for the Indoor Air Quality Monitor for CO2, VOC and Formaldehyde

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.