High-Volume Air Sampler for TSP and PM10
TSP 和 PM10 大流量空气采样器
- SKU AIM-0003
- Air Monitoring
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Sampling flow rate | 1.05 m³/min (adjustable 0.8–1.3) |
|---|---|
| Flow accuracy | ±2% |
| Filter size | 203 × 254 mm |
| PM10 cut point | 10 ± 0.5 µm at rated flow |
| Timer range | 0–99 h, programmable |
| Flow control | Mass flow controller with T/P compensation |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 12341, EN 14211, EN 14212
What is the High-Volume Air Sampler for TSP and PM10?
A pump-driven sampler that draws large volumes of ambient air, typically 1.05 m³/min, through a quartz or glass fiber filter for gravimetric determination of total suspended particulates or PM10. It is the right choice for reference filter sampling and for analysis of metals and organics on the collected dust.
What is the High-Volume Air Sampler for TSP and PM10?
A pump-driven sampler that draws large volumes of ambient air, typically 1.05 m³/min, through a quartz or glass fiber filter for gravimetric determination of total suspended particulates or PM10. It is the right choice for reference filter sampling and for analysis of metals and organics on the collected dust.
Overview
The high-volume sampler consists of a weatherproof shelter, an inlet head, a filter holder for 203 x 254 mm filters, a brushless blower and a mass flow controller or orifice-based flow recorder. Interchangeable PM10 impactor heads or TSP inlets let users adapt the unit to different fractions. The filter is conditioned and weighed before and after sampling on a microbalance with 0.01 mg readability at controlled humidity, and mass divided by sampled air volume gives concentration. Electronic timers run 24-hour sampling runs, and digital flow control compensates for filter loading. The filter can then be extracted for lead, PAH, arsenic or ionic species. Because it is a gravimetric reference, it requires manual handling but offers the highest defensibility.
How does it work?
Air monitors sample air through an inlet and quantify target components by physical or chemical sensing. Particulate instruments use laser light scattering, beta ray attenuation or gravimetric collection on filters, often after a size-selective inlet such as a PM2.5 impactor. Gas sensing uses electrochemical cells, metal oxide semiconductors, non-dispersive infrared absorption, photoionization, or ultraviolet and chemiluminescence analyzers for reference-grade measurements. Active samplers draw air at a controlled flow, for example 16.7 L/min for PM filters or 0.1 to 1 L/min for sorbent tubes and impingers, while passive samplers rely on diffusion. Meteorological sensors record wind, temperature, humidity and pressure to interpret results. A controller logs data, applies calibration factors and communicates over wireless networks.
What are the key features?
- Constant flow control holds 1.05 m³/min despite filter loading changes.
- Interchangeable TSP and PM10 inlet heads adapt one sampler to several fractions.
- Electronic timer and event log support scheduled 24-hour sampling runs.
- Filter holder accepts 203 x 254 mm quartz or glass fiber filters.
- Weatherproof aluminum shelter protects the blower and electronics outdoors.
- Collected filters are suitable for metals, PAH and ion analysis after weighing.
What are the technical specifications?
A typical high-volume air sampler for tsp and pm10 configuration offers sampling flow rate of 1.05 m³/min (adjustable 0.8–1.3), flow accuracy of ±2%, filter size of 203 × 254 mm, PM10 cut point of 10 ± 0.5 µm at rated flow, timer range of 0–99 h, programmable and flow control of Mass flow controller with T/P compensation. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Volume Air Sampler for TSP and PM10 is used in reference TSP and PM10 sampling, heavy metal deposition studies, PAH and organic aerosol analysis and industrial dust compliance. Across the wider Air Monitoring class, laboratories also deploy it for regional air quality networks, indoor air quality assessment and occupational exposure monitoring.
Which standards and certifications apply?
Relevant standards and methods include EN 12341, EN 14211, EN 14212, EN 14625, EN 14626, ISO 7708, US EPA 40 CFR Part 50 and HJ 653. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Site the inlet away from local sources and obstructions, typically 1.5 to 15 m above ground with a clear airflow, following regulatory siting criteria. Use inert sampling lines such as PTFE for reactive gases and keep them short. Calibrate gas analyzers with certified standards and zero air, and verify flow rates on samplers with a traceable flow meter. Replace filters, pump diaphragms and sensor cells on schedule, and protect instruments from condensation and extreme temperatures with shelters or enclosures. Sensor-based devices drift with humidity and temperature, so collocate with a reference periodically. Document all events, because flagged data is required for validation and for any compliance reporting.
How do I select the right High-Volume Air Sampler for TSP and PM10?
Select a high-volume sampler when gravimetric reference results or chemical analysis of the collected dust are required. It gives no real-time data, unlike laser or beta monitors. In an RFQ, specify TSP and PM10 heads, flow control type, filter size, timer features, shelter and calibration orifice requirements.
How does it compare with other Air Monitoring variants?
Define the pollutants, the required accuracy and the decision the data supports. Regulatory networks need reference or equivalent analyzers, while screening, mapping and community monitoring can use sensor-based units with periodic collocation. For exposure assessment of workers, personal pumps with sorbent tubes or filters are required. Indoor air quality investigations usually use handheld instruments for CO2, temperature, humidity, VOC and particulates. Check range, detection limit, response time, humidity compensation and operating temperature. Consider calibration effort, consumables, power availability and communication. For mobile surveys, consider battery life, GPS and weight. Confirm that the supplier provides calibration certificates and data formats compatible with your reporting platform.
Full specifications
| Sampling flow rate | 1.05 m³/min (adjustable 0.8–1.3) |
|---|---|
| Flow accuracy | ±2% |
| Filter size | 203 × 254 mm |
| PM10 cut point | 10 ± 0.5 µm at rated flow |
| Timer range | 0–99 h, programmable |
| Flow control | Mass flow controller with T/P compensation |
| Blower | Brushless, ≥ 10,000 h service life |
| Pressure drop tolerance | Up to 5 kPa loaded filter |
| Operating temperature | −30 to 50 °C |
| Power supply | 220 VAC, 50 Hz, about 700 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Reference TSP and PM10 sampling
- Heavy metal deposition studies
- PAH and organic aerosol analysis
- Industrial dust compliance
Key features
- Constant flow control holds 1.05 m³/min despite filter loading changes.
- Interchangeable TSP and PM10 inlet heads adapt one sampler to several fractions.
- Electronic timer and event log support scheduled 24-hour sampling runs.
- Filter holder accepts 203 x 254 mm quartz or glass fiber filters.
- Weatherproof aluminum shelter protects the blower and electronics outdoors.
- Collected filters are suitable for metals, PAH and ion analysis after weighing.
Frequently asked questions about High-Volume Air Sampler for TSP and PM10
Glass fiber filters are common for TSP and mass determination, while quartz fiber is used when organic carbon or PAH analysis is planned because it tolerates high-temperature preconditioning. Filters must be equilibrated for 24 hours before weighing.
Flow is verified with a calibrated orifice transfer standard against a multi-point resistance plate set, creating a curve of flow versus pressure drop. Calibration is repeated after maintenance and at intervals such as quarterly, with corrections for temperature and pressure.
Only with a different inlet. A PM2.5 impactor or cyclone head designed for the rated flow is needed, and some models support interchangeable heads. A high-volume PM10 head alone does not produce a valid PM2.5 sample.
It measures particulate matter such as PM2.5 and PM10, gases including CO, CO2, NO2, SO2 and O3, volatile organic compounds, and meteorological variables such as wind, temperature and humidity. Some samplers collect material on filters or sorbents for laboratory analysis.
Laser scattering sensors track trends well but typically overestimate mass at high humidity and vary between units. After collocation and correction against a reference monitor they can reach about 10 to 25 percent error, which suits screening but not compliance.
Active sampling draws air through a filter or sorbent with a pump at a controlled flow, giving time-weighted concentrations over hours. Passive sampling relies on diffusion onto a sorbent over days or weeks, needing no power but giving lower time resolution and accuracy.