Skip to main content
Lab Manufacturers China
Personal Air Sampling Pump for Occupational Exposure — product photo

Personal Air Sampling Pump for Occupational Exposure

职业暴露个体空气采样泵

  • SKU AIM-0004
  • Air Monitoring
  • CE (to be confirmed)
  • ATEX or IECEx for Ex versions (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Flow range (low)5–500 mL/min
Flow range (high)1–5 L/min
Flow accuracy±5% of setpoint
Maximum back pressureUp to 7.5 kPa at 2 L/min
Battery runtime8–12 h (NiMH or Li-ion)
Weight300–600 g
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 12341, EN 14211, EN 14212

What is the Personal Air Sampling Pump for Occupational Exposure?

A wearable, battery-powered pump that draws air at a controlled low flow through a filter cassette, sorbent tube or cyclone attached near a worker's breathing zone. It is the right choice for occupational hygiene surveys of dust, solvents, metals and isocyanates against workplace exposure limits.

What is the Personal Air Sampling Pump for Occupational Exposure?

A wearable, battery-powered pump that draws air at a controlled low flow through a filter cassette, sorbent tube or cyclone attached near a worker's breathing zone. It is the right choice for occupational hygiene surveys of dust, solvents, metals and isocyanates against workplace exposure limits.

Overview

The personal sampling pump is clipped to a belt and connected by flexible tubing to a sampling head positioned on the lapel. It maintains constant flow against back pressure from filters or sorbent tubes, with low-flow models covering 5 to 500 mL/min for charcoal tubes and high-flow models covering 1 to 5 L/min for respirable dust cyclones and inhalable samplers. A microprocessor with electronic flow sensing adjusts motor speed to hold flow within plus or minus 5 percent, and the display shows run time and faults. Pulsation dampening is important for sorbent tubes. Pumps are intrinsically safe versions for hazardous areas. After sampling, cassettes or tubes are sent to an accredited laboratory for gravimetric, ICP or chromatographic analysis.

How does it work?

Air monitors sample air through an inlet and quantify target components by physical or chemical sensing. Particulate instruments use laser light scattering, beta ray attenuation or gravimetric collection on filters, often after a size-selective inlet such as a PM2.5 impactor. Gas sensing uses electrochemical cells, metal oxide semiconductors, non-dispersive infrared absorption, photoionization, or ultraviolet and chemiluminescence analyzers for reference-grade measurements. Active samplers draw air at a controlled flow, for example 16.7 L/min for PM filters or 0.1 to 1 L/min for sorbent tubes and impingers, while passive samplers rely on diffusion. Meteorological sensors record wind, temperature, humidity and pressure to interpret results. A controller logs data, applies calibration factors and communicates over wireless networks.

What are the key features?

  • Constant flow compensation holds flow within plus or minus 5 percent under changing back pressure.
  • Low-flow and high-flow modes cover sorbent tubes, filters and cyclones.
  • Pulsation damping protects sorbent tube collection efficiency.
  • Backlit display shows elapsed time, flow and fault status during the shift.
  • Intrinsically safe versions are available for flammable atmospheres.
  • Lightweight housing with belt clip is comfortable for full-shift wear.

What are the technical specifications?

A typical personal air sampling pump for occupational exposure configuration offers flow range (low) of 5–500 mL/min, flow range (high) of 1–5 L/min, flow accuracy of ±5% of setpoint, maximum back pressure of Up to 7.5 kPa at 2 L/min, battery runtime of 8–12 h (NiMH or Li-ion) and weight of 300–600 g. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Personal Air Sampling Pump for Occupational Exposure is used in respirable crystalline silica surveys, solvent vapor exposure sampling, welding fume and metals sampling and isocyanate and formaldehyde monitoring. Across the wider Air Monitoring class, laboratories also deploy it for regional air quality networks, indoor air quality assessment and occupational exposure monitoring.

Which standards and certifications apply?

Relevant standards and methods include EN 12341, EN 14211, EN 14212, EN 14625, EN 14626, ISO 7708, US EPA 40 CFR Part 50 and HJ 653. Certification candidates for this model are CE, ATEX or IECEx for Ex versions and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Site the inlet away from local sources and obstructions, typically 1.5 to 15 m above ground with a clear airflow, following regulatory siting criteria. Use inert sampling lines such as PTFE for reactive gases and keep them short. Calibrate gas analyzers with certified standards and zero air, and verify flow rates on samplers with a traceable flow meter. Replace filters, pump diaphragms and sensor cells on schedule, and protect instruments from condensation and extreme temperatures with shelters or enclosures. Sensor-based devices drift with humidity and temperature, so collocate with a reference periodically. Document all events, because flagged data is required for validation and for any compliance reporting.

How do I select the right Personal Air Sampling Pump for Occupational Exposure?

Select a personal pump for time-weighted average exposure measurements against occupational limits. Fixed samplers cannot represent individual exposure. In an RFQ, state flow range, back pressure capability, battery runtime, intrinsic safety need, calibration kit and compatible sampling heads such as cyclones or charcoal tubes.

How does it compare with other Air Monitoring variants?

Define the pollutants, the required accuracy and the decision the data supports. Regulatory networks need reference or equivalent analyzers, while screening, mapping and community monitoring can use sensor-based units with periodic collocation. For exposure assessment of workers, personal pumps with sorbent tubes or filters are required. Indoor air quality investigations usually use handheld instruments for CO2, temperature, humidity, VOC and particulates. Check range, detection limit, response time, humidity compensation and operating temperature. Consider calibration effort, consumables, power availability and communication. For mobile surveys, consider battery life, GPS and weight. Confirm that the supplier provides calibration certificates and data formats compatible with your reporting platform.

Full specifications

Full specifications
Flow range (low)5–500 mL/min
Flow range (high)1–5 L/min
Flow accuracy±5% of setpoint
Maximum back pressureUp to 7.5 kPa at 2 L/min
Battery runtime8–12 h (NiMH or Li-ion)
Weight300–600 g
Run-time memoryStores last 10 runs
DisplayBacklit LCD
Operating temperature−10 to 45 °C
Explosion protectionOptional Ex ia (to be confirmed)

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Respirable crystalline silica surveys
  • Solvent vapor exposure sampling
  • Welding fume and metals sampling
  • Isocyanate and formaldehyde monitoring

Key features

  • Constant flow compensation holds flow within plus or minus 5 percent under changing back pressure.
  • Low-flow and high-flow modes cover sorbent tubes, filters and cyclones.
  • Pulsation damping protects sorbent tube collection efficiency.
  • Backlit display shows elapsed time, flow and fault status during the shift.
  • Intrinsically safe versions are available for flammable atmospheres.
  • Lightweight housing with belt clip is comfortable for full-shift wear.

Frequently asked questions about Personal Air Sampling Pump for Occupational Exposure

Connect the pump with the actual sampling head to a primary flow calibrator such as a bubble meter or electronic piston meter, adjust to the target flow and record it before and after the shift. A deviation above 5 percent may invalidate the sample.

Related models

All Air Monitoring

Request a quotation for the Personal Air Sampling Pump for Occupational Exposure

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote