What are -40°C Freezers?

-40 °C freezers are laboratory cabinets that hold materials at about -25 to -45 °C, colder than a standard -20 °C freezer but without the cascade cooling of -80 °C units. They store plasma, tissue, buffers, reagents and stability samples in hospitals, blood services, pharmaceutical QC and research laboratories.

5 models of -40°C Freezers

The 5 models below are current configurations; specifications are confirmed on quotation.

Upright -40 °C Laboratory Freezer

立式 -40 °C 实验室冷冻箱

  • CFE-0001
  • -40°C Freezers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-2-011 test report (to be confirmed)
Temperature range:
-25 to -45 °C
Net capacity:
200-700 L
Cooling method:
Forced air
Refrigerant:
Hydrocarbon or HFC blend
Insulation thickness:
About 90 mm polyurethane
Ambient rating:
10-32 °C

An upright cabinet with shelves and a solid or glass door that holds contents at -25 to -45 °C. It is the standard choice when a laboratory needs easy shelf access to boxes of plasma, reagents or samples at a temperature below -20 °C.

Request a quote
View details

Under-Counter -40 °C Freezer

台下式 -40 °C 冷冻箱

  • CFE-0002
  • -40°C Freezers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • RoHS (to be confirmed)
Temperature range:
-25 to -40 °C
Net capacity:
50-150 L
External height:
820-850 mm
Cooling method:
Direct cooling or fan-assisted
Refrigerant:
R290 or R404A class
Ventilation:
Front breathing

A compact -40 °C cabinet, usually 50 to 150 L, sized to fit under a standard laboratory bench. It gives small laboratories and satellite areas sub -30 °C storage without taking up floor space.

Request a quote
View details

Chest -40 °C Laboratory Freezer

卧式 -40 °C 实验室冷冻箱

  • CFE-0003
  • -40°C Freezers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • GB 4706.13 test report (to be confirmed)
Temperature range:
-25 to -45 °C
Net capacity:
100-500 L
Cooling method:
Direct cooling (wall evaporator)
Insulation thickness:
80-100 mm polyurethane
Baskets supplied:
2-5
Ambient rating:
10-32 °C

A top-opening -40 °C cabinet with capacities from about 100 to 500 L. Cold air stays in the cabinet when the lid is open, so it suits bulk storage of plasma, tissue blocks or reagents that are accessed infrequently.

Request a quote
View details

-40 °C Plasma Storage Freezer with Data Logging

带数据记录的 -40 °C 血浆保存冷冻箱

  • CFE-0004
  • -40°C Freezers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • IEC 61010-2-011 test report (to be confirmed)
Temperature range:
-30 to -45 °C
Net capacity:
300-700 L
Cooling method:
Forced air
Temperature uniformity:
Within ±3 °C at steady state
Display resolution:
0.1 °C
Recorder interval:
1-60 min, selectable

A -40 °C upright freezer built for fresh frozen plasma and regulated biological storage, with an independent chart or electronic recorder, redundant sensors and battery-backed alarms to support audit and accreditation requirements.

Request a quote
View details

Dual-Zone -40 °C Freezer and 2-8 °C Refrigerator Combination

-40 °C 冷冻与 2-8 °C 冷藏双温区组合柜

  • CFE-0005
  • -40°C Freezers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-2-011 test report (to be confirmed)
Refrigerator zone temperature:
2-8 °C
Freezer zone temperature:
-25 to -40 °C
Total net capacity:
300-600 L
Refrigerator zone volume:
150-300 L
Freezer zone volume:
100-250 L
Cooling method:
Forced air (refrigerator), direct or forced air (freezer)

A single cabinet with an independently controlled -40 °C freezer compartment and a 2-8 °C refrigerator compartment. It suits laboratories that need both temperatures for workflow but have limited floor space. Each zone has its own controller and alarms.

Request a quote
View details

Compare -40°C Freezers models

ModelTemperature rangeNet capacityCooling methodRefrigerantInsulation thickness
Upright -40 °C Laboratory FreezerCFE-0001-25 to -45 °C200-700 LForced airHydrocarbon or HFC blendAbout 90 mm polyurethane
Under-Counter -40 °C FreezerCFE-0002-25 to -40 °C50-150 LDirect cooling or fan-assistedR290 or R404A class—
Chest -40 °C Laboratory FreezerCFE-0003-25 to -45 °C100-500 LDirect cooling (wall evaporator)—80-100 mm polyurethane
-40 °C Plasma Storage Freezer with Data LoggingCFE-0004-30 to -45 °C300-700 LForced air——
Dual-Zone -40 °C Freezer and 2-8 °C Refrigerator CombinationCFE-0005——Forced air (refrigerator), direct or forced air (freezer)——

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do -40°C Freezers work?

A -40 °C freezer removes heat through vapor-compression refrigeration. Reaching -40 °C from a 25 °C room needs a larger temperature lift than a -20 °C unit, so manufacturers use either a high-efficiency single-stage circuit with a low-temperature refrigerant blend or a compact two-stage cascade. The compressor moves refrigerant through a condenser, capillary or expansion valve and an evaporator mounted in the cabinet walls or behind the shelves. Polyurethane foam insulation of 80 to 100 mm and a magnetic or heated door gasket limit heat ingress, and a door heater prevents frost bonding. A microprocessor controller reads a platinum resistance sensor and cycles the compressor, while independent alarm circuits watch temperature, door status and power. Forced-air or direct-cooling shelves determine uniformity, with forced air giving a tighter distribution and direct cooling giving faster pull-down and lower energy use.

Which -40°C Freezers variants are available?

  • Upright -40 °C Laboratory Freezer — An upright cabinet with shelves and a solid or glass door that holds contents at -25 to -45 °C.
  • Under-Counter -40 °C Freezer — A compact -40 °C cabinet, usually 50 to 150 L, sized to fit under a standard laboratory bench.
  • Chest -40 °C Laboratory Freezer — A top-opening -40 °C cabinet with capacities from about 100 to 500 L.
  • -40 °C Plasma Storage Freezer with Data Logging — A -40 °C upright freezer built for fresh frozen plasma and regulated biological storage, with an independent chart or electronic recorder, redundant sensors and battery-backed alarms to support audit and accreditation requirements.
  • Dual-Zone -40 °C Freezer and 2-8 °C Refrigerator Combination — A single cabinet with an independently controlled -40 °C freezer compartment and a 2-8 °C refrigerator compartment.

How do I choose the right variant?

Choose a -40 °C freezer when -20 °C is not cold enough but -80 °C is unnecessary. Typical triggers are fresh frozen plasma storage, tissue and enzyme preparations that need to stay below the eutectic point of common buffers, and stability studies at -40 °C. Decide first on the format: under-counter for small volumes at the bench, upright for shelf access, chest for bulk storage, or combination units when one cabinet must also provide 2-8 °C. Next compare uniformity and recovery after door opening, since forced air gives a tighter spread and direct cooling a lower energy use. Check capacity against the inventory, ambient temperature rating, alarm features and data logging, and confirm that the lowest temperature is reachable at full load. If samples must stay below -60 °C, move to a -80 °C freezer instead.

Where are -40°C Freezers used?

-40°C Freezers are specified in fresh frozen plasma storage, tissue and enzyme preparation storage, stability sample storage, reagent and buffer storage and clinical specimen archives.

Which standards and certifications apply?

Work with -40°C Freezers is commonly governed by IEC 61010-2-011, IEC 60335-2-89, ISO 23953, EN 15713, GB/T 21151 and WHO PQS E003. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Install the freezer on a level floor with at least 100 mm of clearance at the sides and 200 mm at the rear and top for airflow, in a room not exceeding the rated ambient, typically 32 °C. Use a dedicated circuit with a voltage stabilizer where mains quality is poor. Allow 24 hours after transport before switching on. Calibrate the controller display against a reference thermometer at installation and annually, and map temperature under load for regulated storage. Defrost direct-cooling models when frost exceeds 5 mm and clean condenser filters every one to three months. Keep the door open as briefly as possible and organize inventory to avoid searching. Connect alarm outputs to a monitoring system and test alarms and backup power quarterly.

Frequently asked questions about -40°C Freezers

They store fresh frozen plasma, tissue, enzymes, buffers, reagents and stability samples that need colder conditions than -20 °C. They suit applications below the eutectic point of common solutions but without the long-term preservation demand that calls for -80 °C.