Under-Counter -40 °C Freezer
台下式 -40 °C 冷冻箱
- SKU CFE-0002
- -40°C Freezers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | -25 to -40 °C |
|---|---|
| Net capacity | 50-150 L |
| External height | 820-850 mm |
| Cooling method | Direct cooling or fan-assisted |
| Refrigerant | R290 or R404A class |
| Ventilation | Front breathing |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-2-011, IEC 60335-2-89, ISO 23953
What is the Under-Counter -40 °C Freezer?
A compact -40 °C cabinet, usually 50 to 150 L, sized to fit under a standard laboratory bench. It gives small laboratories and satellite areas sub -30 °C storage without taking up floor space.
What is the Under-Counter -40 °C Freezer?
A compact -40 °C cabinet, usually 50 to 150 L, sized to fit under a standard laboratory bench. It gives small laboratories and satellite areas sub -30 °C storage without taking up floor space.
Overview
The under-counter model has a height of 820 to 850 mm so that it slides beneath a laboratory bench and offers a work surface on top. It is used where a few boxes of plasma, tissue or reagents must remain close to the point of use. Direct-cooling evaporator plates or a small forced-air system cool the cabinet, and a front-opening door with drawers lets users access contents. Capacity is limited, so temperature recovery is quick but total storage is small. Ventilation is front-breathing in many models so that side clearance can be minimal. Use an external temperature logger for regulated storage because compact units often have basic alarms. Under-counter freezers are practical for clinical satellite laboratories and teaching facilities.
How does it work?
A -40 °C freezer removes heat through vapor-compression refrigeration. Reaching -40 °C from a 25 °C room needs a larger temperature lift than a -20 °C unit, so manufacturers use either a high-efficiency single-stage circuit with a low-temperature refrigerant blend or a compact two-stage cascade. The compressor moves refrigerant through a condenser, capillary or expansion valve and an evaporator mounted in the cabinet walls or behind the shelves. Polyurethane foam insulation of 80 to 100 mm and a magnetic or heated door gasket limit heat ingress, and a door heater prevents frost bonding. A microprocessor controller reads a platinum resistance sensor and cycles the compressor, while independent alarm circuits watch temperature, door status and power. Forced-air or direct-cooling shelves determine uniformity, with forced air giving a tighter distribution and direct cooling giving faster pull-down and lower energy use.
What are the key features?
- Height of about 830 mm fits beneath a standard laboratory bench.
- Front ventilation allows installation with minimal side and rear clearance.
- Worktop surface of stainless steel or laminate provides extra bench space.
- Drawer or basket interior keeps small sample boxes within reach.
- Fast temperature recovery due to small internal volume.
- Audible and visual alarms for temperature deviation and door ajar.
What are the technical specifications?
A typical under-counter -40 °c freezer configuration offers temperature range of -25 to -40 °C, net capacity of 50-150 L, external height of 820-850 mm, cooling method of Direct cooling or fan-assisted, refrigerant of R290 or R404A class and ventilation of Front breathing. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Under-Counter -40 °C Freezer is used in satellite clinical laboratories, teaching laboratories, point-of-use reagent storage and small plasma inventories. Across the wider -40°C Freezers class, laboratories also deploy it for fresh frozen plasma storage, tissue and enzyme preparation storage and stability sample storage.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-2-011, IEC 60335-2-89, ISO 23953, EN 15713, GB/T 21151 and WHO PQS E003. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the freezer on a level floor with at least 100 mm of clearance at the sides and 200 mm at the rear and top for airflow, in a room not exceeding the rated ambient, typically 32 °C. Use a dedicated circuit with a voltage stabilizer where mains quality is poor. Allow 24 hours after transport before switching on. Calibrate the controller display against a reference thermometer at installation and annually, and map temperature under load for regulated storage. Defrost direct-cooling models when frost exceeds 5 mm and clean condenser filters every one to three months. Keep the door open as briefly as possible and organize inventory to avoid searching. Connect alarm outputs to a monitoring system and test alarms and backup power quarterly.
How do I select the right Under-Counter -40 °C Freezer?
Select the under-counter model when storage volume is under about 150 L and bench space is tight. It cannot match the capacity or uniformity of upright units. In an RFQ, give the maximum cabinet height and width, ventilation requirement, temperature target, alarm outputs and whether a worktop surface is needed.
How does it compare with other -40°C Freezers variants?
Choose a -40 °C freezer when -20 °C is not cold enough but -80 °C is unnecessary. Typical triggers are fresh frozen plasma storage, tissue and enzyme preparations that need to stay below the eutectic point of common buffers, and stability studies at -40 °C. Decide first on the format: under-counter for small volumes at the bench, upright for shelf access, chest for bulk storage, or combination units when one cabinet must also provide 2-8 °C. Next compare uniformity and recovery after door opening, since forced air gives a tighter spread and direct cooling a lower energy use. Check capacity against the inventory, ambient temperature rating, alarm features and data logging, and confirm that the lowest temperature is reachable at full load. If samples must stay below -60 °C, move to a -80 °C freezer instead.
Full specifications
| Temperature range | -25 to -40 °C |
|---|---|
| Net capacity | 50-150 L |
| External height | 820-850 mm |
| Cooling method | Direct cooling or fan-assisted |
| Refrigerant | R290 or R404A class |
| Ventilation | Front breathing |
| Ambient rating | 10-32 °C |
| Drawers or baskets | 2-4 |
| Power supply | 220 V, 50 Hz |
| Power consumption | About 1.5-3 kWh/day |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Satellite clinical laboratories
- Teaching laboratories
- Point-of-use reagent storage
- Small plasma inventories
Key features
- Height of about 830 mm fits beneath a standard laboratory bench.
- Front ventilation allows installation with minimal side and rear clearance.
- Worktop surface of stainless steel or laminate provides extra bench space.
- Drawer or basket interior keeps small sample boxes within reach.
- Fast temperature recovery due to small internal volume.
- Audible and visual alarms for temperature deviation and door ajar.
Frequently asked questions about Under-Counter -40 °C Freezer
Many compact units reach -40 °C empty under 25 °C ambient but may only hold -30 to -35 °C when fully loaded and often opened. Confirm the specified temperature at full load with your supplier.
Yes. Front-breathing units discharge heat through a front grille, so they can be placed between cabinets with little side clearance. Rear-breathing units need space behind and will overheat if enclosed.
Stainless steel or chemical-resistant laminate tops handle most routine cleaning agents, but acids and strong solvents can damage laminates. Confirm resistance with the supplier for your reagents.
They store fresh frozen plasma, tissue, enzymes, buffers, reagents and stability samples that need colder conditions than -20 °C. They suit applications below the eutectic point of common solutions but without the long-term preservation demand that calls for -80 °C.
No. Nucleic acids, proteins and cell lines for long-term retention are normally stored at -80 °C or lower, and some protocols require it. A -40 °C freezer cannot reach those temperatures and should not be used for them.
Forced air gives a tighter temperature distribution and faster recovery after door opening. Direct cooling uses less energy and avoids airflow over samples but can show larger gradients. Choose based on whether uniformity or efficiency matters more to your inventory.
Related models




Dual-Zone -40 °C Freezer and 2-8 °C Refrigerator Combination
-40 °C 冷冻与 2-8 °C 冷藏双温区组合柜
- CE (to be confirmed)
- +2