Chest -40 °C Laboratory Freezer
卧式 -40 °C 实验室冷冻箱
- SKU CFE-0003
- -40°C Freezers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- GB 4706.13 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | -25 to -45 °C |
|---|---|
| Net capacity | 100-500 L |
| Cooling method | Direct cooling (wall evaporator) |
| Insulation thickness | 80-100 mm polyurethane |
| Baskets supplied | 2-5 |
| Ambient rating | 10-32 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-2-011, IEC 60335-2-89, ISO 23953
What is the Chest -40 °C Laboratory Freezer?
A top-opening -40 °C cabinet with capacities from about 100 to 500 L. Cold air stays in the cabinet when the lid is open, so it suits bulk storage of plasma, tissue blocks or reagents that are accessed infrequently.
What is the Chest -40 °C Laboratory Freezer?
A top-opening -40 °C cabinet with capacities from about 100 to 500 L. Cold air stays in the cabinet when the lid is open, so it suits bulk storage of plasma, tissue blocks or reagents that are accessed infrequently.
Overview
A chest freezer opens from the top, and because cold air is denser than warm air it remains in the well when the lid is raised. This gives better temperature stability, faster recovery and lower energy use than an upright unit of similar volume. The trade-off is accessibility: items at the bottom require removal of those above, so baskets or dividers are used to structure contents. The lid is counterbalanced, often with a lock, and a drain plug assists defrosting. Direct cooling through the walls is typical, which gives low energy use and limited airflow over samples, although gradients are larger than with forced-air systems. Chest -40 °C freezers are common in blood services, slaughterhouse and food laboratories, and archive storage.
How does it work?
A -40 °C freezer removes heat through vapor-compression refrigeration. Reaching -40 °C from a 25 °C room needs a larger temperature lift than a -20 °C unit, so manufacturers use either a high-efficiency single-stage circuit with a low-temperature refrigerant blend or a compact two-stage cascade. The compressor moves refrigerant through a condenser, capillary or expansion valve and an evaporator mounted in the cabinet walls or behind the shelves. Polyurethane foam insulation of 80 to 100 mm and a magnetic or heated door gasket limit heat ingress, and a door heater prevents frost bonding. A microprocessor controller reads a platinum resistance sensor and cycles the compressor, while independent alarm circuits watch temperature, door status and power. Forced-air or direct-cooling shelves determine uniformity, with forced air giving a tighter distribution and direct cooling giving faster pull-down and lower energy use.
What are the key features?
- Top-opening design retains cold air and stabilizes temperature during access.
- Counterbalanced lid with lock supports one-handed operation and secure storage.
- Removable baskets and dividers organize bulk contents by lot or batch.
- Direct-cooling walls provide low energy consumption per liter.
- Drain port simplifies defrosting and cleaning.
- Digital controller with high and low alarms and optional remote contact.
What are the technical specifications?
A typical chest -40 °c laboratory freezer configuration offers temperature range of -25 to -45 °C, net capacity of 100-500 L, cooling method of Direct cooling (wall evaporator), insulation thickness of 80-100 mm polyurethane, baskets supplied of 2-5 and ambient rating of 10-32 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Chest -40 °C Laboratory Freezer is used in bulk plasma storage, tissue block archives, food and environmental retained samples and reagent stock storage. Across the wider -40°C Freezers class, laboratories also deploy it for fresh frozen plasma storage, tissue and enzyme preparation storage and stability sample storage.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-2-011, IEC 60335-2-89, ISO 23953, EN 15713, GB/T 21151 and WHO PQS E003. Certification candidates for this model are CE, ISO 9001 manufacturing and GB 4706.13 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the freezer on a level floor with at least 100 mm of clearance at the sides and 200 mm at the rear and top for airflow, in a room not exceeding the rated ambient, typically 32 °C. Use a dedicated circuit with a voltage stabilizer where mains quality is poor. Allow 24 hours after transport before switching on. Calibrate the controller display against a reference thermometer at installation and annually, and map temperature under load for regulated storage. Defrost direct-cooling models when frost exceeds 5 mm and clean condenser filters every one to three months. Keep the door open as briefly as possible and organize inventory to avoid searching. Connect alarm outputs to a monitoring system and test alarms and backup power quarterly.
How do I select the right Chest -40 °C Laboratory Freezer?
Select the chest format for bulk, low-access storage where energy use and temperature stability matter more than shelf-level access. Uprights are easier to inventory. For an RFQ, provide the required net volume, basket layout, lid lock, floor space and the alarm or logging interface required.
How does it compare with other -40°C Freezers variants?
Choose a -40 °C freezer when -20 °C is not cold enough but -80 °C is unnecessary. Typical triggers are fresh frozen plasma storage, tissue and enzyme preparations that need to stay below the eutectic point of common buffers, and stability studies at -40 °C. Decide first on the format: under-counter for small volumes at the bench, upright for shelf access, chest for bulk storage, or combination units when one cabinet must also provide 2-8 °C. Next compare uniformity and recovery after door opening, since forced air gives a tighter spread and direct cooling a lower energy use. Check capacity against the inventory, ambient temperature rating, alarm features and data logging, and confirm that the lowest temperature is reachable at full load. If samples must stay below -60 °C, move to a -80 °C freezer instead.
Full specifications
| Temperature range | -25 to -45 °C |
|---|---|
| Net capacity | 100-500 L |
| Cooling method | Direct cooling (wall evaporator) |
| Insulation thickness | 80-100 mm polyurethane |
| Baskets supplied | 2-5 |
| Ambient rating | 10-32 °C |
| Pull-down time | Under 6 h from 25 °C to -40 °C, empty |
| Lid lock | Key lock |
| Power supply | 220 V, 50 Hz |
| Power consumption | About 2-5 kWh/day |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Bulk plasma storage
- Tissue block archives
- Food and environmental retained samples
- Reagent stock storage
Key features
- Top-opening design retains cold air and stabilizes temperature during access.
- Counterbalanced lid with lock supports one-handed operation and secure storage.
- Removable baskets and dividers organize bulk contents by lot or batch.
- Direct-cooling walls provide low energy consumption per liter.
- Drain port simplifies defrosting and cleaning.
- Digital controller with high and low alarms and optional remote contact.
Frequently asked questions about Chest -40 °C Laboratory Freezer
Cold air is heavier than warm air and stays in the well when the lid opens, so less heat enters and the compressor runs less. At equal volume and temperature, chest units typically use less energy than uprights.
Use stackable baskets or dividers labeled by lot and date, place frequently needed items at the top, and keep a location map so the lid does not stay open while searching.
Direct-cooling chest freezers form frost on the walls and need manual defrosting when the layer reaches about 5 to 10 mm. Move contents to a backup freezer, defrost, dry and restart.
They store fresh frozen plasma, tissue, enzymes, buffers, reagents and stability samples that need colder conditions than -20 °C. They suit applications below the eutectic point of common solutions but without the long-term preservation demand that calls for -80 °C.
No. Nucleic acids, proteins and cell lines for long-term retention are normally stored at -80 °C or lower, and some protocols require it. A -40 °C freezer cannot reach those temperatures and should not be used for them.
Forced air gives a tighter temperature distribution and faster recovery after door opening. Direct cooling uses less energy and avoids airflow over samples but can show larger gradients. Choose based on whether uniformity or efficiency matters more to your inventory.