-40 °C Plasma Storage Freezer with Data Logging
带数据记录的 -40 °C 血浆保存冷冻箱
- SKU CFE-0004
- -40°C Freezers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- IEC 61010-2-011 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | -30 to -45 °C |
|---|---|
| Net capacity | 300-700 L |
| Cooling method | Forced air |
| Temperature uniformity | Within ±3 °C at steady state |
| Display resolution | 0.1 °C |
| Recorder interval | 1-60 min, selectable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-2-011, IEC 60335-2-89, ISO 23953
What is the -40 °C Plasma Storage Freezer with Data Logging?
A -40 °C upright freezer built for fresh frozen plasma and regulated biological storage, with an independent chart or electronic recorder, redundant sensors and battery-backed alarms to support audit and accreditation requirements.
What is the -40 °C Plasma Storage Freezer with Data Logging?
A -40 °C upright freezer built for fresh frozen plasma and regulated biological storage, with an independent chart or electronic recorder, redundant sensors and battery-backed alarms to support audit and accreditation requirements.
Overview
This variant adds compliance features to a standard upright -40 °C freezer. A second temperature probe feeds an independent recorder that keeps logging when the controller fails, and data can be exported through USB or an Ethernet interface for audit trails. Battery-backed alarms continue for 12 hours or longer after a power cut, and remote notification can be delivered by SMS or dry contacts. Shelf layouts are designed for plasma bags in racks or cassettes, and a fast recovery profile protects product temperature during dispatch. The cabinet typically holds 300 to 700 L. Mapping under load is usually performed with the facility's own validation process, and the freezer is selected with calibration certificates and documentation to support blood service and hospital transfusion quality systems.
How does it work?
A -40 °C freezer removes heat through vapor-compression refrigeration. Reaching -40 °C from a 25 °C room needs a larger temperature lift than a -20 °C unit, so manufacturers use either a high-efficiency single-stage circuit with a low-temperature refrigerant blend or a compact two-stage cascade. The compressor moves refrigerant through a condenser, capillary or expansion valve and an evaporator mounted in the cabinet walls or behind the shelves. Polyurethane foam insulation of 80 to 100 mm and a magnetic or heated door gasket limit heat ingress, and a door heater prevents frost bonding. A microprocessor controller reads a platinum resistance sensor and cycles the compressor, while independent alarm circuits watch temperature, door status and power. Forced-air or direct-cooling shelves determine uniformity, with forced air giving a tighter distribution and direct cooling giving faster pull-down and lower energy use.
What are the key features?
- Independent recorder with second probe continues logging if the controller fails.
- USB or Ethernet export supports audit trails and electronic records.
- Battery-backed alarm continues for at least 12 hours after power failure.
- Shelf and rack layout is arranged for plasma bags and cassettes.
- Fast temperature recovery after door opening protects product during dispatch.
- Calibration certificate and documentation package support quality-system use.
What are the technical specifications?
A typical -40 °c plasma storage freezer with data logging configuration offers temperature range of -30 to -45 °C, net capacity of 300-700 L, cooling method of Forced air, temperature uniformity of Within ±3 °C at steady state, display resolution of 0.1 °C and recorder interval of 1-60 min, selectable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The -40 °C Plasma Storage Freezer with Data Logging is used in blood service plasma storage, hospital transfusion laboratories, clinical trial sample storage and regulated biological storage. Across the wider -40°C Freezers class, laboratories also deploy it for fresh frozen plasma storage, tissue and enzyme preparation storage and stability sample storage.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-2-011, IEC 60335-2-89, ISO 23953, EN 15713, GB/T 21151 and WHO PQS E003. Certification candidates for this model are CE, ISO 13485 manufacturing and IEC 61010-2-011 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the freezer on a level floor with at least 100 mm of clearance at the sides and 200 mm at the rear and top for airflow, in a room not exceeding the rated ambient, typically 32 °C. Use a dedicated circuit with a voltage stabilizer where mains quality is poor. Allow 24 hours after transport before switching on. Calibrate the controller display against a reference thermometer at installation and annually, and map temperature under load for regulated storage. Defrost direct-cooling models when frost exceeds 5 mm and clean condenser filters every one to three months. Keep the door open as briefly as possible and organize inventory to avoid searching. Connect alarm outputs to a monitoring system and test alarms and backup power quarterly.
How do I select the right -40 °C Plasma Storage Freezer with Data Logging?
Select this variant when plasma or regulated samples need traceable temperature records and dependable alarms. A standard upright is enough for unregulated stock. Specify the target temperature, recorder type and interval, data interface, battery hours, rack configuration, calibration certificate and mapping support.
How does it compare with other -40°C Freezers variants?
Choose a -40 °C freezer when -20 °C is not cold enough but -80 °C is unnecessary. Typical triggers are fresh frozen plasma storage, tissue and enzyme preparations that need to stay below the eutectic point of common buffers, and stability studies at -40 °C. Decide first on the format: under-counter for small volumes at the bench, upright for shelf access, chest for bulk storage, or combination units when one cabinet must also provide 2-8 °C. Next compare uniformity and recovery after door opening, since forced air gives a tighter spread and direct cooling a lower energy use. Check capacity against the inventory, ambient temperature rating, alarm features and data logging, and confirm that the lowest temperature is reachable at full load. If samples must stay below -60 °C, move to a -80 °C freezer instead.
Full specifications
| Temperature range | -30 to -45 °C |
|---|---|
| Net capacity | 300-700 L |
| Cooling method | Forced air |
| Temperature uniformity | Within ±3 °C at steady state |
| Display resolution | 0.1 °C |
| Recorder interval | 1-60 min, selectable |
| Data interface | USB, RS-485 or Ethernet |
| Alarm battery backup | 12 h or longer |
| Recovery after door open (1 min) | Under 30 min |
| Power supply | 220 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Blood service plasma storage
- Hospital transfusion laboratories
- Clinical trial sample storage
- Regulated biological storage
Key features
- Independent recorder with second probe continues logging if the controller fails.
- USB or Ethernet export supports audit trails and electronic records.
- Battery-backed alarm continues for at least 12 hours after power failure.
- Shelf and rack layout is arranged for plasma bags and cassettes.
- Fast temperature recovery after door opening protects product during dispatch.
- Calibration certificate and documentation package support quality-system use.
Frequently asked questions about -40 °C Plasma Storage Freezer with Data Logging
Guidance from many blood services requires storage at -25 °C or colder, with -30 °C or colder commonly specified for longer shelf life. Follow your national standard and accreditation rules.
If the controller or its sensor fails, the control system may also stop logging. An independent recorder with its own probe gives a separate temperature history for audits and investigations.
Yes. USB or network export lets records be stored in a validated system. Where 21 CFR Part 11 or similar rules apply, confirm access control and audit-trail features with the supplier.
They store fresh frozen plasma, tissue, enzymes, buffers, reagents and stability samples that need colder conditions than -20 °C. They suit applications below the eutectic point of common solutions but without the long-term preservation demand that calls for -80 °C.
No. Nucleic acids, proteins and cell lines for long-term retention are normally stored at -80 °C or lower, and some protocols require it. A -40 °C freezer cannot reach those temperatures and should not be used for them.
Forced air gives a tighter temperature distribution and faster recovery after door opening. Direct cooling uses less energy and avoids airflow over samples but can show larger gradients. Choose based on whether uniformity or efficiency matters more to your inventory.