Frost-Free Upright –20 °C Freezer
无霜立式 –20 °C 冷冻箱
- SKU CFR-0003
- -20°C Freezers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | –10 to –25 °C |
|---|---|
| Net volume | 250–600 L |
| Temperature uniformity | ≤ 4 K |
| Cooling method | Forced-air, hidden evaporator |
| Defrost | Automatic heater, every 8–12 h |
| Defrost temperature rise | Up to approx. 5 K (air) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-011, IEC 61326-1
What is the Frost-Free Upright –20 °C Freezer?
An upright –20 °C freezer with forced-air cooling and automatic defrost, removing the need to empty the cabinet for ice removal. It suits laboratories that value convenience and low maintenance and whose contents tolerate brief defrost warm-ups.
What is the Frost-Free Upright –20 °C Freezer?
An upright –20 °C freezer with forced-air cooling and automatic defrost, removing the need to empty the cabinet for ice removal. It suits laboratories that value convenience and low maintenance and whose contents tolerate brief defrost warm-ups.
Overview
Frost-free freezers circulate air across an evaporator hidden behind a rear panel, with a heater that periodically melts frost, usually every 8 to 12 hours. Condensate drains away and evaporates, so shelves remain free of ice. Air circulation produces better temperature uniformity than static designs, often within 3–4 K, and fast recovery after door opening. The drawback is temperature cycling: during defrost, the air can warm by several degrees, and stored items can experience small freeze–thaw cycles. This is acceptable for many chemicals and media, but not for some enzymes and sensitive biologicals, which are best kept in static or ultra-low units. Volumes of 250–600 L and adjustable shelves are typical. Energy use is higher than in static models.
How does it work?
A –20 °C freezer uses a single-stage vapour-compression circuit with hydrocarbon refrigerant such as R600a or R290. The evaporator either lines the compartment as plates, giving static cooling with high stability and manual defrost, or sits behind a panel with a fan, giving forced-air cooling and automatic defrost. Polyurethane foam of 60–80 mm provides insulation, and magnetic gaskets limit air leakage. A microprocessor controller reads a sensor, sets the temperature between –10 and –25 °C and drives alarms. Higher-specification models add an independent alarm probe, battery backup and a data logger. Spark-free models relocate controls outside the compartment for flammable storage. The temperature reached is sufficient to slow chemical degradation and enzyme activity but does not stop them entirely.
What are the key features?
- Automatic defrost eliminates the need to empty the cabinet
- Forced-air circulation improves temperature uniformity
- Fast temperature recovery after door opening
- Adjustable shelves suit boxes and bottles of different sizes
- Alarm set includes high temperature, door ajar and sensor failure
What are the technical specifications?
A typical frost-free upright –20 °c freezer configuration offers temperature range of –10 to –25 °C, net volume of 250–600 L, temperature uniformity of ≤ 4 K, cooling method of Forced-air, hidden evaporator, defrost of Automatic heater, every 8–12 h and defrost temperature rise of Up to approx. 5 K (air). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Frost-Free Upright –20 °C Freezer is used in general chemical storage, culture media storage, food and environmental sample storage and kit storage in QC laboratories. Across the wider -20°C Freezers class, laboratories also deploy it for enzyme and reagent storage, diagnostic kit storage and culture media and supplements.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-011, IEC 61326-1, ISO 15189, NFPA 45 and ISO 9001. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the freezer on a level floor with clearance for ventilation as specified, away from heat and sunlight, and allow it to run for several hours before loading. Avoid overloading and block-free airflow in fan-assisted models. Defrost static units when frost reaches about 5 mm, and clean the condenser every few months. Calibrate probes and alarms at least annually, and map temperature where storage is regulated. Keep an emergency plan for power failure, including backup freezer space or a generator-backed circuit. Do not store flammable liquids unless the unit is specifically built for it.
How do I select the right Frost-Free Upright –20 °C Freezer?
Choose the frost-free model when convenience matters and contents are not sensitive to brief warm-ups. Specify volume, number of shelves and alarm needs. For enzymes, nucleic acids and sensitive biologicals, choose a static or ultra-low freezer to avoid defrost cycling.
How does it compare with other -20°C Freezers variants?
Choose by what is stored and how it tolerates temperature change. Enzymes and sensitive reagents favour static, manual-defrost cabinets, while general chemicals and media suit frost-free models. Regulated kits and calibrators need independent alarms and logging. Flammable materials require spark-free or explosion-proof designs. Then select capacity, from 100 L undercounter to 600 L upright, and compare temperature uniformity, recovery, drawer layout and lock. Check ambient range, electrical supply and noise. Consider whether –20 °C is sufficient, because many biological samples, nucleic acids and tissues are kept at –80 °C for long-term stability, and some vaccines need different storage.
Full specifications
| Temperature range | –10 to –25 °C |
|---|---|
| Net volume | 250–600 L |
| Temperature uniformity | ≤ 4 K |
| Cooling method | Forced-air, hidden evaporator |
| Defrost | Automatic heater, every 8–12 h |
| Defrost temperature rise | Up to approx. 5 K (air) |
| Refrigerant | R600a or R290 |
| Shelves | 4–6 adjustable |
| Alarms | High temperature, door ajar, sensor failure |
| Power supply | 220–240 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- General chemical storage
- Culture media storage
- Food and environmental sample storage
- Kit storage in QC laboratories
Key features
- Automatic defrost eliminates the need to empty the cabinet
- Forced-air circulation improves temperature uniformity
- Fast temperature recovery after door opening
- Adjustable shelves suit boxes and bottles of different sizes
- Alarm set includes high temperature, door ajar and sensor failure
Frequently asked questions about Frost-Free Upright –20 °C Freezer
Repeated small warm-ups during defrost can reduce activity of some enzymes, particularly over long storage, and may cause freeze–thaw damage. For sensitive reagents, use a manual-defrost (static) freezer or store in insulated boxes with glycerol-containing buffers.
Air temperature near the evaporator can rise by several kelvin for a few minutes, although product temperature rises less because of thermal mass. Ask the manufacturer for defrost profiles and map the cabinet if the contents are regulated.
Yes, typically 10–30 percent more than a comparable static unit, because of the defrost heater and fan. Actual figures depend on ambient temperature, loading and door openings, so compare kWh per day data at the same conditions.
A –20 °C laboratory freezer is a cabinet that holds contents at about –10 to –25 °C. It stores enzymes, reagents, kits, media and samples that need sub-zero storage but not the –80 °C used for long-term biological samples.
Typical contents are restriction enzymes, polymerases, antibiotics, reagent kits, media supplements, antibodies for short-term use and frozen chemical standards. Always follow the manufacturer's label, since some reagents require –80 °C or refrigeration.
Manual-defrost freezers hold temperature more stably, so they suit enzymes and sensitive reagents. Frost-free models are more convenient and uniform, but cycle temperature during defrost, which can harm sensitive contents. Choose according to what is stored.