Lab Manufacturers China
Frost-Free Upright –20 °C Freezer — product photo

Frost-Free Upright –20 °C Freezer

无霜立式 –20 °C 冷冻箱

  • SKU CFR-0003
  • -20°C Freezers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature range–10 to –25 °C
Net volume250–600 L
Temperature uniformity≤ 4 K
Cooling methodForced-air, hidden evaporator
DefrostAutomatic heater, every 8–12 h
Defrost temperature riseUp to approx. 5 K (air)
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-011, IEC 61326-1

What is the Frost-Free Upright –20 °C Freezer?

An upright –20 °C freezer with forced-air cooling and automatic defrost, removing the need to empty the cabinet for ice removal. It suits laboratories that value convenience and low maintenance and whose contents tolerate brief defrost warm-ups.

What is the Frost-Free Upright –20 °C Freezer?

An upright –20 °C freezer with forced-air cooling and automatic defrost, removing the need to empty the cabinet for ice removal. It suits laboratories that value convenience and low maintenance and whose contents tolerate brief defrost warm-ups.

Overview

Frost-free freezers circulate air across an evaporator hidden behind a rear panel, with a heater that periodically melts frost, usually every 8 to 12 hours. Condensate drains away and evaporates, so shelves remain free of ice. Air circulation produces better temperature uniformity than static designs, often within 3–4 K, and fast recovery after door opening. The drawback is temperature cycling: during defrost, the air can warm by several degrees, and stored items can experience small freeze–thaw cycles. This is acceptable for many chemicals and media, but not for some enzymes and sensitive biologicals, which are best kept in static or ultra-low units. Volumes of 250–600 L and adjustable shelves are typical. Energy use is higher than in static models.

How does it work?

A –20 °C freezer uses a single-stage vapour-compression circuit with hydrocarbon refrigerant such as R600a or R290. The evaporator either lines the compartment as plates, giving static cooling with high stability and manual defrost, or sits behind a panel with a fan, giving forced-air cooling and automatic defrost. Polyurethane foam of 60–80 mm provides insulation, and magnetic gaskets limit air leakage. A microprocessor controller reads a sensor, sets the temperature between –10 and –25 °C and drives alarms. Higher-specification models add an independent alarm probe, battery backup and a data logger. Spark-free models relocate controls outside the compartment for flammable storage. The temperature reached is sufficient to slow chemical degradation and enzyme activity but does not stop them entirely.

What are the key features?

  • Automatic defrost eliminates the need to empty the cabinet
  • Forced-air circulation improves temperature uniformity
  • Fast temperature recovery after door opening
  • Adjustable shelves suit boxes and bottles of different sizes
  • Alarm set includes high temperature, door ajar and sensor failure

What are the technical specifications?

A typical frost-free upright –20 °c freezer configuration offers temperature range of –10 to –25 °C, net volume of 250–600 L, temperature uniformity of ≤ 4 K, cooling method of Forced-air, hidden evaporator, defrost of Automatic heater, every 8–12 h and defrost temperature rise of Up to approx. 5 K (air). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Frost-Free Upright –20 °C Freezer is used in general chemical storage, culture media storage, food and environmental sample storage and kit storage in QC laboratories. Across the wider -20°C Freezers class, laboratories also deploy it for enzyme and reagent storage, diagnostic kit storage and culture media and supplements.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-011, IEC 61326-1, ISO 15189, NFPA 45 and ISO 9001. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the freezer on a level floor with clearance for ventilation as specified, away from heat and sunlight, and allow it to run for several hours before loading. Avoid overloading and block-free airflow in fan-assisted models. Defrost static units when frost reaches about 5 mm, and clean the condenser every few months. Calibrate probes and alarms at least annually, and map temperature where storage is regulated. Keep an emergency plan for power failure, including backup freezer space or a generator-backed circuit. Do not store flammable liquids unless the unit is specifically built for it.

How do I select the right Frost-Free Upright –20 °C Freezer?

Choose the frost-free model when convenience matters and contents are not sensitive to brief warm-ups. Specify volume, number of shelves and alarm needs. For enzymes, nucleic acids and sensitive biologicals, choose a static or ultra-low freezer to avoid defrost cycling.

How does it compare with other -20°C Freezers variants?

Choose by what is stored and how it tolerates temperature change. Enzymes and sensitive reagents favour static, manual-defrost cabinets, while general chemicals and media suit frost-free models. Regulated kits and calibrators need independent alarms and logging. Flammable materials require spark-free or explosion-proof designs. Then select capacity, from 100 L undercounter to 600 L upright, and compare temperature uniformity, recovery, drawer layout and lock. Check ambient range, electrical supply and noise. Consider whether –20 °C is sufficient, because many biological samples, nucleic acids and tissues are kept at –80 °C for long-term stability, and some vaccines need different storage.

Full specifications

Full specifications
Temperature range–10 to –25 °C
Net volume250–600 L
Temperature uniformity≤ 4 K
Cooling methodForced-air, hidden evaporator
DefrostAutomatic heater, every 8–12 h
Defrost temperature riseUp to approx. 5 K (air)
RefrigerantR600a or R290
Shelves4–6 adjustable
AlarmsHigh temperature, door ajar, sensor failure
Power supply220–240 V, 50 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • General chemical storage
  • Culture media storage
  • Food and environmental sample storage
  • Kit storage in QC laboratories

Key features

  • Automatic defrost eliminates the need to empty the cabinet
  • Forced-air circulation improves temperature uniformity
  • Fast temperature recovery after door opening
  • Adjustable shelves suit boxes and bottles of different sizes
  • Alarm set includes high temperature, door ajar and sensor failure

Frequently asked questions about Frost-Free Upright –20 °C Freezer

Repeated small warm-ups during defrost can reduce activity of some enzymes, particularly over long storage, and may cause freeze–thaw damage. For sensitive reagents, use a manual-defrost (static) freezer or store in insulated boxes with glycerol-containing buffers.