What are Spectrophotometers?

Spectrophotometers for water analysis measure light absorbance of water samples or reagent-developed colors to determine parameters such as ammonia nitrogen, phosphate, COD, residual chlorine, nitrate, iron and color. They are used by water utilities, environmental laboratories and industrial plants for routine compliance and process testing.

5 models of Spectrophotometers

The 5 models below are current configurations; specifications are confirmed on quotation.

Visible Spectrophotometer for Colorimetric Water Testing

水质比色检测用可见分光光度计

  • SPT-0001
  • Spectrophotometers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Wavelength range:
340–1000 nm
Spectral bandwidth:
4 nm
Wavelength accuracy:
± 2 nm
Photometric range:
−0.3–3.0 A
Photometric accuracy:
± 0.005 A (0–0.5 A)
Stray light:
≤ 0.1% T at 360 nm

A single-beam visible-range spectrophotometer covering 340 to 1000 nm, used for reagent-based colorimetric tests on ammonia, phosphate, iron, chlorine and similar parameters. It is the economical workhorse for laboratories running a limited test list in standard 10 to 30 mm cells.

Request a quote
View details

UV-Vis Spectrophotometer for Water Analysis with Preset Methods

带预设方法的水质分析 UV-Vis 分光光度计

  • SPT-0002
  • Spectrophotometers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Wavelength range:
190–1100 nm
Spectral bandwidth:
1 nm or 2 nm (selectable)
Wavelength accuracy:
± 0.5 nm
Photometric range:
−4–4 A
Photometric accuracy:
± 0.002 A (0–1 A)
Stray light:
≤ 0.05% T at 220 nm and 340 nm

A double-wavelength or scanning UV-Vis spectrophotometer covering 190 to 1100 nm, loaded with preset water methods for nitrate, UV254, COD and color. It suits laboratories that need both visible colorimetry and direct UV absorbance measurements on one platform.

Request a quote
View details

COD Rapid Analyzer with Digestion Reactor and Photometer

带消解反应器和光度计的 COD 快速测定仪

  • SPT-0003
  • Spectrophotometers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Digestion temperature:
150 °C ± 2 °C
Digestion wells:
16 or 25
Digestion time:
120 min (programmable 10–180 min)
Measuring wavelengths:
420 nm and 600 nm
COD ranges:
0–150, 0–1500, 0–15,000 mg/L
Accuracy:
± 5% of reading or ± 3 mg/L

An integrated system combining a thermostatted digestion block and a dedicated photometer for chemical oxygen demand. It reads sealed reagent tubes after 2 hours of digestion at 150 °C, giving COD results in mg/L for wastewater laboratories without titration.

Request a quote
View details

Portable Spectrophotometer for Field Water Quality Testing

现场水质检测便携式分光光度计

  • SPT-0004
  • Spectrophotometers
  • CE (to be confirmed)
  • RoHS (to be confirmed)
Wavelength range:
400–900 nm (LED or grating)
Preset methods:
50–100
Free chlorine range:
0.02–2.00 mg/L
Photometric accuracy:
± 0.01 A
Wavelength accuracy:
± 2 nm
Vial format:
16 mm vial, 10–25 mm cell

A battery-powered handheld photometer or spectrophotometer with 50 to 100 preset water methods and IP-rated housing. It supports on-site testing of chlorine, ammonia, phosphate, iron and fluoride at treatment plants, distribution networks, wells and discharge points, where samples cannot wait for a central laboratory.

Request a quote
View details

Online UV Absorbance Analyzer for Organic Load Monitoring

有机负荷监测用在线紫外吸光度分析仪

  • SPT-0005
  • Spectrophotometers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Measuring principle:
UV absorbance at 254 nm or 200–750 nm spectrum
Optical path length:
1, 5, 10, 50 or 100 mm
Absorbance range:
0–3 A
SAC254 range:
0–600 1/m (typical, path dependent)
Response time:
< 10 s
Cleaning:
Automatic wiper or compressed air

A reagent-free inline analyzer that measures UV absorbance at 254 nm, or full UV spectra, in flowing water. It gives continuous indicators of organic load, nitrate and color at intakes, treatment stages and outfalls, without sampling or chemicals.

Request a quote
View details

Compare Spectrophotometers models

ModelWavelength rangeSpectral bandwidthWavelength accuracyPhotometric rangePhotometric accuracy
Visible Spectrophotometer for Colorimetric Water TestingSPT-0001340–1000 nm4 nm± 2 nm−0.3–3.0 A± 0.005 A (0–0.5 A)
UV-Vis Spectrophotometer for Water Analysis with Preset MethodsSPT-0002190–1100 nm1 nm or 2 nm (selectable)± 0.5 nm−4–4 A± 0.002 A (0–1 A)
COD Rapid Analyzer with Digestion Reactor and PhotometerSPT-0003—————
Portable Spectrophotometer for Field Water Quality TestingSPT-0004400–900 nm (LED or grating)—± 2 nm—± 0.01 A
Online UV Absorbance Analyzer for Organic Load MonitoringSPT-0005—————

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Spectrophotometers work?

These instruments apply the Beer–Lambert law: absorbance at a chosen wavelength is proportional to the concentration of the absorbing species and the optical path length. For most water tests, a reagent converts the analyte into a colored complex, for example indophenol blue for ammonia, molybdenum blue for orthophosphate, DPD for free chlorine and dichromate reduction for COD. A tungsten-halogen or LED source passes light through a monochromator or interference filter, then through a cuvette or vial to a silicon photodiode or array detector. Readings are compared with a blank and a calibration curve to report mg/L. Water-specific models add pre-programmed methods, barcode-recognized reagent vials, digestion blocks and flow cells to reduce manual steps. UV absorbance at 254 nm is also used directly as a surrogate for dissolved organic matter.

Which Spectrophotometers variants are available?

  • Visible Spectrophotometer for Colorimetric Water Testing — A single-beam visible-range spectrophotometer covering 340 to 1000 nm, used for reagent-based colorimetric tests on ammonia, phosphate, iron, chlorine and similar parameters.
  • UV-Vis Spectrophotometer for Water Analysis with Preset Methods — A double-wavelength or scanning UV-Vis spectrophotometer covering 190 to 1100 nm, loaded with preset water methods for nitrate, UV254, COD and color.
  • COD Rapid Analyzer with Digestion Reactor and Photometer — An integrated system combining a thermostatted digestion block and a dedicated photometer for chemical oxygen demand.
  • Portable Spectrophotometer for Field Water Quality Testing — A battery-powered handheld photometer or spectrophotometer with 50 to 100 preset water methods and IP-rated housing.
  • Online UV Absorbance Analyzer for Organic Load Monitoring — A reagent-free inline analyzer that measures UV absorbance at 254 nm, or full UV spectra, in flowing water.

How do I choose the right variant?

Start from the test list and methods you must run. If you report a handful of colorimetric parameters, a visible-range instrument with pre-programmed methods is sufficient. If you need nitrate, UV254 or other UV-absorbing parameters, choose a UV-Vis model. Match throughput to the format: cuvette-based instruments suit flexible method development, while vial-based systems with barcodes cut errors in high-volume testing. For COD, an integrated digestion reactor and photometer reduces handling. Field teams need battery operation and IP-rated housings. Check wavelength accuracy and photometric stability, because trace-level tests near detection limits demand low noise. Also confirm that reagent chemistries follow recognized methods such as ISO, EPA or HJ and that the supplier can provide traceable calibration standards and validation data.

Where are Spectrophotometers used?

Spectrophotometers are specified in ammonia nitrogen and phosphorus determination, COD testing for wastewater discharge, residual chlorine monitoring in disinfection, iron, manganese and silica in boiler water and color and UV254 screening of organic load.

Which standards and certifications apply?

Work with Spectrophotometers is commonly governed by ISO 7150-1, ISO 6878, ISO 7393-2, HJ 535, HJ 828, HJ 636, USP <857>, JJG 178 and IEC 61010-1. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Warm the lamp as specified and zero with reagent blanks prepared from the same water. Use matched, scratch-free cuvettes or vials, clean the optical windows and keep reagents within expiry and storage temperature. Verify wavelength accuracy and photometric linearity with holmium oxide and neutral-density or potassium dichromate standards at least annually, and run a mid-range check standard with each batch. Dispose of mercury-, chromium- and sulfuric acid-containing reagent waste, particularly from COD digestion, in accordance with local rules. Place the instrument away from direct sunlight, vibration and drafts. Laboratories operating under ISO/IEC 17025 should record lamp hours, calibration dates and control charts.

Frequently asked questions about Spectrophotometers

It measures any analyte that forms a colored complex or absorbs light directly. Typical parameters are ammonia nitrogen, nitrite, nitrate, total phosphorus, COD, residual chlorine, iron, manganese, copper, phenol, sulfate, silica, color and UV254 absorbance.

Need help specifying Spectrophotometers?