UV-Vis Spectrophotometer for Water Analysis with Preset Methods
带预设方法的水质分析 UV-Vis 分光光度计
- CE (to be confirmed)
- +1
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

水质比色检测用可见分光光度计
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Wavelength range | 340–1000 nm |
|---|---|
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ± 2 nm |
| Photometric range | −0.3–3.0 A |
| Photometric accuracy | ± 0.005 A (0–0.5 A) |
| Stray light | ≤ 0.1% T at 360 nm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7150-1, ISO 6878, ISO 7393-2
A single-beam visible-range spectrophotometer covering 340 to 1000 nm, used for reagent-based colorimetric tests on ammonia, phosphate, iron, chlorine and similar parameters. It is the economical workhorse for laboratories running a limited test list in standard 10 to 30 mm cells.
A single-beam visible-range spectrophotometer covering 340 to 1000 nm, used for reagent-based colorimetric tests on ammonia, phosphate, iron, chlorine and similar parameters. It is the economical workhorse for laboratories running a limited test list in standard 10 to 30 mm cells.
This variant uses a tungsten-halogen lamp, a grating monochromator with 4 nm spectral bandwidth and a silicon photodiode detector. Wavelength accuracy of ± 2 nm and photometric accuracy of ± 0.005 A at 0.5 A suffice for most standard colorimetric methods. A large sample compartment accepts 10, 20 and 30 mm cuvettes and a 16 mm tube adapter, letting one instrument serve reagent kits and standard methods. A touch screen stores user-defined calibration curves and a library of common water methods with concentration readout. Internal data memory and USB or RS-232 output make results easy to transfer to a LIMS. The photometric range of −0.3 to 3 A supports tests from sub-mg/L ammonia to high-range iron. Without UV capability, the instrument cannot perform nitrate or UV254 measurements by direct absorbance. It has a short warm-up of about 15 minutes and requires a mains supply.
These instruments apply the Beer–Lambert law: absorbance at a chosen wavelength is proportional to the concentration of the absorbing species and the optical path length. For most water tests, a reagent converts the analyte into a colored complex, for example indophenol blue for ammonia, molybdenum blue for orthophosphate, DPD for free chlorine and dichromate reduction for COD. A tungsten-halogen or LED source passes light through a monochromator or interference filter, then through a cuvette or vial to a silicon photodiode or array detector. Readings are compared with a blank and a calibration curve to report mg/L. Water-specific models add pre-programmed methods, barcode-recognized reagent vials, digestion blocks and flow cells to reduce manual steps. UV absorbance at 254 nm is also used directly as a surrogate for dissolved organic matter.
A typical visible spectrophotometer for colorimetric water testing configuration offers wavelength range of 340–1000 nm, spectral bandwidth of 4 nm, wavelength accuracy of ± 2 nm, photometric range of −0.3–3.0 A, photometric accuracy of ± 0.005 A (0–0.5 A) and stray light of ≤ 0.1% T at 360 nm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Visible Spectrophotometer for Colorimetric Water Testing is used in ammonia nitrogen and total phosphorus by standard methods, iron, manganese and copper in drinking water, teaching and training laboratories and plant laboratories running a short test list. Across the wider Spectrophotometers class, laboratories also deploy it for ammonia nitrogen and phosphorus determination, COD testing for wastewater discharge and residual chlorine monitoring in disinfection.
Relevant standards and methods include ISO 7150-1, ISO 6878, ISO 7393-2, HJ 535, HJ 828, HJ 636, USP <857>, JJG 178 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Warm the lamp as specified and zero with reagent blanks prepared from the same water. Use matched, scratch-free cuvettes or vials, clean the optical windows and keep reagents within expiry and storage temperature. Verify wavelength accuracy and photometric linearity with holmium oxide and neutral-density or potassium dichromate standards at least annually, and run a mid-range check standard with each batch. Dispose of mercury-, chromium- and sulfuric acid-containing reagent waste, particularly from COD digestion, in accordance with local rules. Place the instrument away from direct sunlight, vibration and drafts. Laboratories operating under ISO/IEC 17025 should record lamp hours, calibration dates and control charts.
Choose this variant when all required tests use colored complexes above 340 nm and the budget favors a simple instrument. Select a UV-Vis model if nitrate by UV or UV254 is needed. In an RFQ, specify wavelength range, bandwidth, cell sizes, method library contents, data interface and any JJG 178 verification requirements.
Start from the test list and methods you must run. If you report a handful of colorimetric parameters, a visible-range instrument with pre-programmed methods is sufficient. If you need nitrate, UV254 or other UV-absorbing parameters, choose a UV-Vis model. Match throughput to the format: cuvette-based instruments suit flexible method development, while vial-based systems with barcodes cut errors in high-volume testing. For COD, an integrated digestion reactor and photometer reduces handling. Field teams need battery operation and IP-rated housings. Check wavelength accuracy and photometric stability, because trace-level tests near detection limits demand low noise. Also confirm that reagent chemistries follow recognized methods such as ISO, EPA or HJ and that the supplier can provide traceable calibration standards and validation data.
| Wavelength range | 340–1000 nm |
|---|---|
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ± 2 nm |
| Photometric range | −0.3–3.0 A |
| Photometric accuracy | ± 0.005 A (0–0.5 A) |
| Stray light | ≤ 0.1% T at 360 nm |
| Light source | Tungsten-halogen lamp |
| Detector | Silicon photodiode |
| Display | 5.7 in color touch screen |
| Power supply | AC 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Yes, by colorimetric methods such as cadmium reduction or chromotropic acid that produce a visible color. It cannot do direct UV nitrate at 220 nm, which requires a UV-capable spectrophotometer.
Use the longest available path, such as 30 mm, for low-concentration tests, since absorbance scales linearly with path length. Keep the final absorbance between 0.1 and 1.0 A, and use matched cells and a reagent blank for best accuracy.
Typically 1,500 to 2,000 hours of use. Switching the lamp off between long gaps extends life, while falling energy at short wavelengths or noisy readings signal it needs replacement. Re-verify wavelength and photometric accuracy afterward.
It measures any analyte that forms a colored complex or absorbs light directly. Typical parameters are ammonia nitrogen, nitrite, nitrate, total phosphorus, COD, residual chlorine, iron, manganese, copper, phenol, sulfate, silica, color and UV254 absorbance.
A water sample is heated with potassium dichromate and sulfuric acid, usually at 150 °C for two hours, oxidizing organics. The photometer then measures the change in chromium color at 600 nm (Cr3+) or 420 nm (Cr6+) and converts it to COD in mg/L by calibration.
A spectrophotometer selects wavelengths continuously, so it can run many methods and verify peaks. A colorimeter uses fixed filters, is simpler and cheaper and works well for a limited set of tests. For multi-method laboratories, a spectrophotometer is the more flexible option.