What are Food Composition Analysis?

Food composition analysis determines the nutrient content of food and feed rapidly and accurately. It covers near-infrared and mid-infrared analysers, bomb calorimeters, refractometers, enzymatic analysers and salt analysers for moisture, fat, protein, sugar, energy and sodium in raw materials and finished products.

6 models of Food Composition Analysis

The 6 models below are current configurations; specifications are confirmed on quotation.

Near-Infrared Food Composition Analyzer

近红外食品成分分析仪

  • FCA-0001
  • Food Composition Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Wavelength range:
850–2500 nm
Measurement mode:
Reflectance and transmission
Analysis time:
30–60 s per sample
Moisture range:
0.5–60 percent
Protein range:
5–90 percent (dry basis)
Fat range:
0.5–60 percent

A near-infrared food composition analyser measures moisture, fat, protein and carbohydrate in grains, powders and liquids by reflectance or transmission spectroscopy. It is the rapid method of choice when a laboratory needs multi-parameter results in under a minute without reagents.

Request a quote
View details

Fourier-Transform Mid-Infrared Milk Analyzer

傅里叶变换中红外乳品分析仪

  • FCA-0002
  • Food Composition Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ISO 9622 method conformity (to be confirmed)
Spectral range:
3000–1000 cm⁻¹
Components measured:
Fat, protein, lactose, total solids, urea
Throughput:
200–600 samples/h
Fat repeatability:
CV ≤ 1 percent
Protein repeatability:
CV ≤ 1 percent
Sample temperature:
38–42 °C

An FT-MIR milk analyser measures fat, protein, lactose, total solids and urea in milk and dairy products from mid-infrared absorption. It is used where milk payments and product standardisation require accurate compositional data at several hundred samples per hour.

Request a quote
View details

Bomb Calorimeter for Food Energy Determination

食品能量测定氧弹量热仪

  • FCA-0003
  • Food Composition Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Working pressure:
25–30 bar oxygen
Bomb volume:
300–350 mL
Sample mass:
0.5–1.5 g pellet
Energy range:
Up to 40 MJ/kg
Repeatability:
≤ 0.2 percent RSD
Temperature resolution:
0.0001 °C

A bomb calorimeter measures the gross energy content of food and feed by combusting a pelleted sample in oxygen and recording the temperature rise of the surrounding water. It provides the calorific value used for energy labelling, feed evaluation and research.

Request a quote
View details

Digital Refractometer for Brix and Sugar Measurement

数字折光仪(白利糖度与糖度测量)

  • FCA-0004
  • Food Composition Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Brix range:
0–95 Brix
Resolution:
0.1 Brix
Accuracy:
±0.2 Brix
Refractive index range:
1.3300–1.5100 nD
Temperature compensation:
10–40 °C automatic
Sample volume:
0.2–0.3 mL

A digital refractometer measures Brix, refractive index and often sugar concentration in beverages, syrups and preserves from the refraction of light in a small sample. It is a simple, rapid tool for concentration control on the production line and in the laboratory.

Request a quote
View details

Automated Enzymatic Food Analyzer

自动化酶法食品分析仪

  • FCA-0005
  • Food Composition Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Detection wavelength:
340 nm, 405–630 nm options
Wavelength accuracy:
±1 nm
Temperature control:
25–37 °C, ±0.2 °C
Throughput:
60–300 tests/h
Sample volume:
10–100 µL
Detection range:
0.1–10 g/L per analyte

An automated enzymatic food analyser quantifies sugars, organic acids, starch, ethanol and other specific analytes using enzyme reactions that are read photometrically. It gives high specificity for labelled nutrients and fermentation control without chromatography.

Request a quote
View details

Salt Content Analyzer for Food

食品盐分分析仪

  • FCA-0006
  • Food Composition Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Measurement principle:
Potentiometric titration or conductivity
Salt range:
0.01–10 percent NaCl
Resolution:
0.01 percent NaCl
Repeatability:
≤ 2 percent RSD
Electrode:
Silver or chloride-selective
Sample preparation:
Homogenise and extract in water

A salt content analyser measures sodium chloride in food and feed by potentiometric titration or conductivity, giving the salt figure used for nutrition labelling, taste control and compliance with regulatory sodium targets.

Request a quote
View details

Compare Food Composition Analysis models

ModelWavelength accuracyInterfaceOperating temperatureThroughputSample volume
Near-Infrared Food Composition AnalyzerFCA-0001±0.5 nmUSB, Ethernet, LIMS export15–35 °C——
Fourier-Transform Mid-Infrared Milk AnalyzerFCA-0002—USB, Ethernet, RS-232—200–600 samples/h10–25 mL per test
Bomb Calorimeter for Food Energy DeterminationFCA-0003—————
Digital Refractometer for Brix and Sugar MeasurementFCA-0004————0.2–0.3 mL
Automated Enzymatic Food AnalyzerFCA-0005±1 nm——60–300 tests/h10–100 µL
Salt Content Analyzer for FoodFCA-0006——15–35 °C——

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Food Composition Analysis work?

Composition analysis instruments rely on physical or chemical properties that change with the concentration of the component of interest. Near-infrared and mid-infrared analysers measure absorbance by O–H, C–H and N–H bonds and convert spectra into concentrations with multivariate calibration models. Bomb calorimeters determine gross energy from the heat released during complete combustion in oxygen. Refractometers measure the refractive index, which rises with dissolved solids such as sugars. Enzymatic analysers use specific enzyme reactions coupled to NADH or colorimetric readouts. Salt analysers use potentiometric or conductivity sensing to measure sodium chloride. All secondary methods must be correlated with reference chemistry for each matrix.

Which Food Composition Analysis variants are available?

  • Near-Infrared Food Composition Analyzer — A near-infrared food composition analyser measures moisture, fat, protein and carbohydrate in grains, powders and liquids by reflectance or transmission spectroscopy.
  • Fourier-Transform Mid-Infrared Milk Analyzer — An FT-MIR milk analyser measures fat, protein, lactose, total solids and urea in milk and dairy products from mid-infrared absorption.
  • Bomb Calorimeter for Food Energy Determination — A bomb calorimeter measures the gross energy content of food and feed by combusting a pelleted sample in oxygen and recording the temperature rise of the surrounding water.
  • Digital Refractometer for Brix and Sugar Measurement — A digital refractometer measures Brix, refractive index and often sugar concentration in beverages, syrups and preserves from the refraction of light in a small sample.
  • Automated Enzymatic Food Analyzer — An automated enzymatic food analyser quantifies sugars, organic acids, starch, ethanol and other specific analytes using enzyme reactions that are read photometrically.
  • Salt Content Analyzer for Food — A salt content analyser measures sodium chloride in food and feed by potentiometric titration or conductivity, giving the salt figure used for nutrition labelling, taste control and compliance with regulatory sodium targets.

How do I choose the right variant?

Choose the technique from the parameter and the accuracy you must report. Near-infrared analysers give the fastest multi-parameter results for grains, powders and liquids, but they depend entirely on the calibration set, so they suit high sample numbers and stable matrices. Mid-infrared milk analysers are the accepted tool for dairy payment and standardisation at several hundred samples per hour. Bomb calorimetry is the only direct energy measurement and remains the reference for feed and labelling energy. Refractometry is simple and robust for sugar, juice and syrup control. Enzymatic analysers provide specificity for sugars, organic acids and starch where rapid kits are not accurate enough. Consider consumable use, calibration transfer and service response when comparing platforms.

Where are Food Composition Analysis used?

Food Composition Analysis are specified in nutrition labelling and specification verification, raw-material acceptance in grain, dairy and feed plants, in-process control of blending and drying, dairy payment and product standardisation, feed energy and nutrient evaluation and product development and recipe benchmarking.

Which standards and certifications apply?

Work with Food Composition Analysis is commonly governed by AOAC Official Methods of Analysis, ISO 12099, ISO 6658, ISO 6496, ISO 2171, ISO 8968 and ISO/IEC 17025. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Infrared analysers need a representative calibration set covering the full range of moisture, fat and protein found in routine samples, and the model must be re-validated after major raw-material changes. Temperature and sample presentation strongly affect spectra, so cups and grinder settings should be controlled. Bomb calorimeters require oxygen of high purity, careful pellet preparation and regular benzoic acid checks. Enzymatic and refractometric methods need clean optics, fresh reagents and control samples. Keep records of reference-method comparisons, and confirm that calibrations, service and spare parts remain available for the life of the instrument.