Fourier-Transform Mid-Infrared Milk Analyzer — product photo

Fourier-Transform Mid-Infrared Milk Analyzer

傅里叶变换中红外乳品分析仪

  • SKU FCA-0002
  • Food Composition Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ISO 9622 method conformity (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Spectral range3000–1000 cm⁻¹
Components measuredFat, protein, lactose, total solids, urea
Throughput200–600 samples/h
Fat repeatabilityCV ≤ 1 percent
Protein repeatabilityCV ≤ 1 percent
Sample temperature38–42 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: AOAC Official Methods of Analysis, ISO 12099, ISO 6658

What is the Fourier-Transform Mid-Infrared Milk Analyzer?

An FT-MIR milk analyser measures fat, protein, lactose, total solids and urea in milk and dairy products from mid-infrared absorption. It is used where milk payments and product standardisation require accurate compositional data at several hundred samples per hour.

What is the Fourier-Transform Mid-Infrared Milk Analyzer?

An FT-MIR milk analyser measures fat, protein, lactose, total solids and urea in milk and dairy products from mid-infrared absorption. It is used where milk payments and product standardisation require accurate compositional data at several hundred samples per hour.

Overview

The analyser homogenises the milk and passes it through a short optical cell while a Fourier-transform interferometer records the mid-infrared spectrum, typically between 3000 and 1000 cm⁻¹, where fat, protein and lactose show characteristic ester, amide and hydroxyl bands. A DTGS or MCT detector acquires the full spectrum at once, and multivariate calibration converts absorbance into concentrations. Automated versions handle 200–600 samples per hour with programmed rinsing, zeroing and result export. Some models add conductivity or optical modules for somatic cell counting and urea determination. Because the method is secondary, daily zero and calibration checks against reference standards are required, together with periodic comparison to wet chemistry.

How does it work?

Composition analysis instruments rely on physical or chemical properties that change with the concentration of the component of interest. Near-infrared and mid-infrared analysers measure absorbance by O–H, C–H and N–H bonds and convert spectra into concentrations with multivariate calibration models. Bomb calorimeters determine gross energy from the heat released during complete combustion in oxygen. Refractometers measure the refractive index, which rises with dissolved solids such as sugars. Enzymatic analysers use specific enzyme reactions coupled to NADH or colorimetric readouts. Salt analysers use potentiometric or conductivity sensing to measure sodium chloride. All secondary methods must be correlated with reference chemistry for each matrix.

What are the key features?

  • Mid-infrared range 3000–1000 cm⁻¹ covering fat, protein and lactose
  • Throughput of 200–600 samples per hour with automated sampling
  • Homogeniser and heated cell that prevent fat separation in the flow path
  • Automatic zeroing, rinsing and detergent cleaning cycles
  • Optional conductivity module for somatic cell count
  • Result export to milk-payment and LIMS software

What are the technical specifications?

A typical fourier-transform mid-infrared milk analyzer configuration offers spectral range of 3000–1000 cm⁻¹, components measured of Fat, protein, lactose, total solids, urea, throughput of 200–600 samples/h, fat repeatability of CV ≤ 1 percent, protein repeatability of CV ≤ 1 percent and sample temperature of 38–42 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Fourier-Transform Mid-Infrared Milk Analyzer is used in milk payment and quality-based pricing, raw milk intake testing at dairies, standardisation of fat and protein before processing and yoghurt, ice cream and cheese mix control. Across the wider Food Composition Analysis class, laboratories also deploy it for nutrition labelling and specification verification, raw-material acceptance in grain, dairy and feed plants and in-process control of blending and drying.

Which standards and certifications apply?

Relevant standards and methods include AOAC Official Methods of Analysis, ISO 12099, ISO 6658, ISO 6496, ISO 2171, ISO 8968 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and ISO 9622 method conformity; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Infrared analysers need a representative calibration set covering the full range of moisture, fat and protein found in routine samples, and the model must be re-validated after major raw-material changes. Temperature and sample presentation strongly affect spectra, so cups and grinder settings should be controlled. Bomb calorimeters require oxygen of high purity, careful pellet preparation and regular benzoic acid checks. Enzymatic and refractometric methods need clean optics, fresh reagents and control samples. Keep records of reference-method comparisons, and confirm that calibrations, service and spare parts remain available for the life of the instrument.

How do I select the right Fourier-Transform Mid-Infrared Milk Analyzer?

Select an FT-MIR analyser when dairy volume, payment schemes or standardisation targets justify a dedicated high-throughput instrument. Confirm that the calibration set covers your product range, including goat, sheep or buffalo milk if relevant, and that the reference standards and control samples are available locally. Ask for somatic cell and urea options only if you need them.

How does it compare with other Food Composition Analysis variants?

Choose the technique from the parameter and the accuracy you must report. Near-infrared analysers give the fastest multi-parameter results for grains, powders and liquids, but they depend entirely on the calibration set, so they suit high sample numbers and stable matrices. Mid-infrared milk analysers are the accepted tool for dairy payment and standardisation at several hundred samples per hour. Bomb calorimetry is the only direct energy measurement and remains the reference for feed and labelling energy. Refractometry is simple and robust for sugar, juice and syrup control. Enzymatic analysers provide specificity for sugars, organic acids and starch where rapid kits are not accurate enough. Consider consumable use, calibration transfer and service response when comparing platforms.

Full specifications

Full specifications
Spectral range3000–1000 cm⁻¹
Components measuredFat, protein, lactose, total solids, urea
Throughput200–600 samples/h
Fat repeatabilityCV ≤ 1 percent
Protein repeatabilityCV ≤ 1 percent
Sample temperature38–42 °C
Sample volume10–25 mL per test
DetectorDTGS or MCT
CleaningAutomatic rinse and detergent cycle
InterfaceUSB, Ethernet, RS-232

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Milk payment and quality-based pricing
  • Raw milk intake testing at dairies
  • Standardisation of fat and protein before processing
  • Yoghurt, ice cream and cheese mix control

Key features

  • Mid-infrared range 3000–1000 cm⁻¹ covering fat, protein and lactose
  • Throughput of 200–600 samples per hour with automated sampling
  • Homogeniser and heated cell that prevent fat separation in the flow path
  • Automatic zeroing, rinsing and detergent cleaning cycles
  • Optional conductivity module for somatic cell count
  • Result export to milk-payment and LIMS software

Frequently asked questions about Fourier-Transform Mid-Infrared Milk Analyzer

It reports fat, protein, lactose, total solids and often urea in milk and dairy mixes. Somatic cell count and freezing point may be added through optional modules. Calibration is specific to the species and product type being tested.

Request a quotation for the Fourier-Transform Mid-Infrared Milk Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote