Bomb Calorimeter for Food Energy Determination
食品能量测定氧弹量热仪
- SKU FCA-0003
- Food Composition Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Working pressure | 25–30 bar oxygen |
|---|---|
| Bomb volume | 300–350 mL |
| Sample mass | 0.5–1.5 g pellet |
| Energy range | Up to 40 MJ/kg |
| Repeatability | ≤ 0.2 percent RSD |
| Temperature resolution | 0.0001 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: AOAC Official Methods of Analysis, ISO 12099, ISO 6658
What is the Bomb Calorimeter for Food Energy Determination?
A bomb calorimeter measures the gross energy content of food and feed by combusting a pelleted sample in oxygen and recording the temperature rise of the surrounding water. It provides the calorific value used for energy labelling, feed evaluation and research.
What is the Bomb Calorimeter for Food Energy Determination?
A bomb calorimeter measures the gross energy content of food and feed by combusting a pelleted sample in oxygen and recording the temperature rise of the surrounding water. It provides the calorific value used for energy labelling, feed evaluation and research.
Overview
A weighed pellet of dried, homogenised sample is placed in a stainless-steel bomb, which is sealed and filled with oxygen at about 25–30 bar. Ignition by an electrical fuse wire burns the sample completely, and the heat released raises the temperature of a measured water jacket or a solid jacket of known heat capacity. The temperature rise, corrected for fuse wire and acid formation, gives the gross heat of combustion in MJ/kg or kcal/100 g. Modern isoperibol and adiabatic instruments automate filling, firing, temperature logging and calculation, achieving repeatability better than 0.2 percent. Because gross energy includes the energy of combustion of protein and fibre, results are higher than metabolisable energy values used on some feed labels.
How does it work?
Composition analysis instruments rely on physical or chemical properties that change with the concentration of the component of interest. Near-infrared and mid-infrared analysers measure absorbance by O–H, C–H and N–H bonds and convert spectra into concentrations with multivariate calibration models. Bomb calorimeters determine gross energy from the heat released during complete combustion in oxygen. Refractometers measure the refractive index, which rises with dissolved solids such as sugars. Enzymatic analysers use specific enzyme reactions coupled to NADH or colorimetric readouts. Salt analysers use potentiometric or conductivity sensing to measure sodium chloride. All secondary methods must be correlated with reference chemistry for each matrix.
What are the key features?
- Sealed oxygen bomb rated for 25–30 bar working pressure
- Automatic oxygen filling, ignition and temperature logging
- Repeatability better than 0.2 percent on benzoic acid checks
- Pellet press and drying accessories for sample preparation
- Calculation of gross energy in MJ/kg or kcal/100 g
- Software with calibration records and export of results
What are the technical specifications?
A typical bomb calorimeter for food energy determination configuration offers working pressure of 25–30 bar oxygen, bomb volume of 300–350 mL, sample mass of 0.5–1.5 g pellet, energy range of Up to 40 MJ/kg, repeatability of ≤ 0.2 percent RSD and temperature resolution of 0.0001 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Bomb Calorimeter for Food Energy Determination is used in gross energy determination for feed and pet food, energy value verification for nutrition labelling, research on high-fibre and novel ingredients and calorific value of food processing by-products. Across the wider Food Composition Analysis class, laboratories also deploy it for nutrition labelling and specification verification, raw-material acceptance in grain, dairy and feed plants and in-process control of blending and drying.
Which standards and certifications apply?
Relevant standards and methods include AOAC Official Methods of Analysis, ISO 12099, ISO 6658, ISO 6496, ISO 2171, ISO 8968 and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Infrared analysers need a representative calibration set covering the full range of moisture, fat and protein found in routine samples, and the model must be re-validated after major raw-material changes. Temperature and sample presentation strongly affect spectra, so cups and grinder settings should be controlled. Bomb calorimeters require oxygen of high purity, careful pellet preparation and regular benzoic acid checks. Enzymatic and refractometric methods need clean optics, fresh reagents and control samples. Keep records of reference-method comparisons, and confirm that calibrations, service and spare parts remain available for the life of the instrument.
How do I select the right Bomb Calorimeter for Food Energy Determination?
Choose bomb calorimetry when you need a direct, traceable gross energy value rather than one calculated from fat, protein and carbohydrate. Specify bomb volume and sample mass for your typical matrices, and confirm the repeatability you require and the availability of certified benzoic acid. Look for automatic oxygen handling and a fume-exhaust connection to protect the operator.
How does it compare with other Food Composition Analysis variants?
Choose the technique from the parameter and the accuracy you must report. Near-infrared analysers give the fastest multi-parameter results for grains, powders and liquids, but they depend entirely on the calibration set, so they suit high sample numbers and stable matrices. Mid-infrared milk analysers are the accepted tool for dairy payment and standardisation at several hundred samples per hour. Bomb calorimetry is the only direct energy measurement and remains the reference for feed and labelling energy. Refractometry is simple and robust for sugar, juice and syrup control. Enzymatic analysers provide specificity for sugars, organic acids and starch where rapid kits are not accurate enough. Consider consumable use, calibration transfer and service response when comparing platforms.
Full specifications
| Working pressure | 25–30 bar oxygen |
|---|---|
| Bomb volume | 300–350 mL |
| Sample mass | 0.5–1.5 g pellet |
| Energy range | Up to 40 MJ/kg |
| Repeatability | ≤ 0.2 percent RSD |
| Temperature resolution | 0.0001 °C |
| Calibration standard | Benzoic acid, certified |
| Test time | 8–15 min per sample |
| Jacket type | Isoperibol or adiabatic |
| Data output | USB, printer, LIMS export |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Gross energy determination for feed and pet food
- Energy value verification for nutrition labelling
- Research on high-fibre and novel ingredients
- Calorific value of food processing by-products
Key features
- Sealed oxygen bomb rated for 25–30 bar working pressure
- Automatic oxygen filling, ignition and temperature logging
- Repeatability better than 0.2 percent on benzoic acid checks
- Pellet press and drying accessories for sample preparation
- Calculation of gross energy in MJ/kg or kcal/100 g
- Software with calibration records and export of results
Frequently asked questions about Bomb Calorimeter for Food Energy Determination
Gross energy is the total heat released when a sample burns completely, measured directly by bomb calorimetry. Metabolisable energy subtracts energy lost in faeces, urine and gases, so it is lower and is calculated for feed formulations.
The sample is homogenised and dried, then pressed into a pellet of known mass. Liquid or fatty samples may be encapsulated or absorbed on a combustion aid. Consistent preparation is essential because the result is reported per unit mass.
Complete combustion requires an excess of oxygen at elevated pressure so that all carbon and hydrogen are fully oxidised. The bomb is filled to about 25–30 bar, and residual gas is vented safely after each test.
Near-infrared and mid-infrared analysers measure composition in 30 to 60 seconds with no reagents, provided a calibration model for that product has been built and validated against reference chemistry. They are screening and process tools rather than referee methods.
A Brix refractometer measures dissolved solids, mostly sugars, from the refractive index of a clear liquid. It is used for fruit juice, soft drinks, syrups and preserves to check concentration and to control evaporation or blending.
A bomb calorimeter directly measures gross energy by combusting the sample in oxygen. It is the reference for feed energy values and is used where calculated energy from fat, protein and carbohydrate would be inaccurate, such as high-fibre or novel ingredients.