

Near-Infrared Food Composition Analyzer
近红外食品成分分析仪
- SKU FCA-0001
- Food Composition Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength range | 850–2500 nm |
|---|---|
| Measurement mode | Reflectance and transmission |
| Analysis time | 30–60 s per sample |
| Moisture range | 0.5–60 percent |
| Protein range | 5–90 percent (dry basis) |
| Fat range | 0.5–60 percent |
By Lab Manufacturers China Technical TeamLast reviewed Standards: AOAC Official Methods of Analysis, ISO 12099, ISO 6658
What is the Near-Infrared Food Composition Analyzer?
A near-infrared food composition analyser measures moisture, fat, protein and carbohydrate in grains, powders and liquids by reflectance or transmission spectroscopy. It is the rapid method of choice when a laboratory needs multi-parameter results in under a minute without reagents.
What is the Near-Infrared Food Composition Analyzer?
A near-infrared food composition analyser measures moisture, fat, protein and carbohydrate in grains, powders and liquids by reflectance or transmission spectroscopy. It is the rapid method of choice when a laboratory needs multi-parameter results in under a minute without reagents.
Overview
The analyser illuminates the sample with near-infrared light and measures the reflected or transmitted spectrum, in which absorption bands arise from O–H, C–H and N–H bonds. A chemometric model, built from samples whose composition was determined by reference chemistry, converts the spectrum into quantitative values. Bench systems accept grains, powders, pastes and liquids in cups or through a transport cell, and typical analysis time is 30–60 seconds per sample with minimal consumables. The wavelength range usually spans 850–2500 nm with a monochromator, diode array or Fourier-transform interferometer. Accuracy depends on the calibration set, so instruments are validated against Kjeldahl, Soxhlet and oven methods for the matrices in use.
How does it work?
Composition analysis instruments rely on physical or chemical properties that change with the concentration of the component of interest. Near-infrared and mid-infrared analysers measure absorbance by O–H, C–H and N–H bonds and convert spectra into concentrations with multivariate calibration models. Bomb calorimeters determine gross energy from the heat released during complete combustion in oxygen. Refractometers measure the refractive index, which rises with dissolved solids such as sugars. Enzymatic analysers use specific enzyme reactions coupled to NADH or colorimetric readouts. Salt analysers use potentiometric or conductivity sensing to measure sodium chloride. All secondary methods must be correlated with reference chemistry for each matrix.
What are the key features?
- Wavelength coverage 850–2500 nm for moisture, fat, protein and carbohydrate
- Non-destructive measurement with no reagents or solvent disposal
- Analysis time of 30–60 seconds per sample for high throughput
- Calibration transfer tools for consistent results across instruments
- Rotating sample cup for representative measurement of powders and grains
- Built-in spectral quality checks that flag outliers outside the model range
What are the technical specifications?
A typical near-infrared food composition analyzer configuration offers wavelength range of 850–2500 nm, measurement mode of Reflectance and transmission, analysis time of 30–60 s per sample, moisture range of 0.5–60 percent, protein range of 5–90 percent (dry basis) and fat range of 0.5–60 percent. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Near-Infrared Food Composition Analyzer is used in grain and flour moisture and protein testing, dairy powder composition screening, snack and bakery process control and feed ingredient evaluation. Across the wider Food Composition Analysis class, laboratories also deploy it for nutrition labelling and specification verification, raw-material acceptance in grain, dairy and feed plants and in-process control of blending and drying.
Which standards and certifications apply?
Relevant standards and methods include AOAC Official Methods of Analysis, ISO 12099, ISO 6658, ISO 6496, ISO 2171, ISO 8968 and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Infrared analysers need a representative calibration set covering the full range of moisture, fat and protein found in routine samples, and the model must be re-validated after major raw-material changes. Temperature and sample presentation strongly affect spectra, so cups and grinder settings should be controlled. Bomb calorimeters require oxygen of high purity, careful pellet preparation and regular benzoic acid checks. Enzymatic and refractometric methods need clean optics, fresh reagents and control samples. Keep records of reference-method comparisons, and confirm that calibrations, service and spare parts remain available for the life of the instrument.
How do I select the right Near-Infrared Food Composition Analyzer?
Choose the near-infrared analyser when you process many similar samples and need moisture, fat and protein within a minute, and when you can invest in building and maintaining a calibration set. Specify wavelength range, sample presentation for your matrices and the availability of calibration transfer. In the RFQ, request reference-method correlation studies and a plan for periodic bias correction.
How does it compare with other Food Composition Analysis variants?
Choose the technique from the parameter and the accuracy you must report. Near-infrared analysers give the fastest multi-parameter results for grains, powders and liquids, but they depend entirely on the calibration set, so they suit high sample numbers and stable matrices. Mid-infrared milk analysers are the accepted tool for dairy payment and standardisation at several hundred samples per hour. Bomb calorimetry is the only direct energy measurement and remains the reference for feed and labelling energy. Refractometry is simple and robust for sugar, juice and syrup control. Enzymatic analysers provide specificity for sugars, organic acids and starch where rapid kits are not accurate enough. Consider consumable use, calibration transfer and service response when comparing platforms.
Full specifications
| Wavelength range | 850–2500 nm |
|---|---|
| Measurement mode | Reflectance and transmission |
| Analysis time | 30–60 s per sample |
| Moisture range | 0.5–60 percent |
| Protein range | 5–90 percent (dry basis) |
| Fat range | 0.5–60 percent |
| Wavelength accuracy | ±0.5 nm |
| Calibration approach | Partial least squares regression |
| Sample presentation | Rotating cup, 90 mm diameter |
| Interface | USB, Ethernet, LIMS export |
| Operating temperature | 15–35 °C |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Grain and flour moisture and protein testing
- Dairy powder composition screening
- Snack and bakery process control
- Feed ingredient evaluation
Key features
- Wavelength coverage 850–2500 nm for moisture, fat, protein and carbohydrate
- Non-destructive measurement with no reagents or solvent disposal
- Analysis time of 30–60 seconds per sample for high throughput
- Calibration transfer tools for consistent results across instruments
- Rotating sample cup for representative measurement of powders and grains
- Built-in spectral quality checks that flag outliers outside the model range
Frequently asked questions about Near-Infrared Food Composition Analyzer
Yes. The instrument is a secondary method, so its calibration is built from samples analysed by Kjeldahl, Soxhlet or oven drying. Without enough representative reference samples, results may be biased for new products or seasons.
Many bench models support both modes through interchangeable cups or a flow cell, but the calibration is product-specific. Each matrix needs its own model and its own sample-presentation method, so confirm the range of accessories before purchase.
A useful model normally needs 50 to 200 representative samples spanning the expected range, analysed by reference chemistry over weeks or months. Transferring an existing supplier model to your products shortens the process but still requires verification.
Near-infrared and mid-infrared analysers measure composition in 30 to 60 seconds with no reagents, provided a calibration model for that product has been built and validated against reference chemistry. They are screening and process tools rather than referee methods.
A Brix refractometer measures dissolved solids, mostly sugars, from the refractive index of a clear liquid. It is used for fruit juice, soft drinks, syrups and preserves to check concentration and to control evaporation or blending.
A bomb calorimeter directly measures gross energy by combusting the sample in oxygen. It is the reference for feed energy values and is used where calculated energy from fat, protein and carbohydrate would be inaccurate, such as high-fibre or novel ingredients.
Related models





