What are Kjeldahl Systems?

Kjeldahl systems determine nitrogen and protein in food, feed and water by acid digestion, alkaline distillation and titration. The subcategory covers manual and automated digestion blocks, steam distillation units, integrated nitrogen analyzers and micro-Kjeldahl systems used in reference laboratories.

5 models of Kjeldahl Systems

The 5 models below are current configurations; specifications are confirmed on quotation.

Manual Kjeldahl Digestion Block

手动凯氏消解仪

  • KJS-0001
  • Kjeldahl Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Positions:
6–12 tubes
Tube volume:
250 mL or 400 mL
Temperature range:
Ambient to 450 °C
Temperature stability:
±2 °C
Heating block:
Aluminium or graphite
Digestion time:
45–120 min depending on matrix

A manual Kjeldahl digestion block heats digestion tubes in a controlled aluminium block for acid digestion of food and feed samples. It is a simple, low-cost entry into the Kjeldahl method for low-throughput laboratories.

Request a quote
View details

Automated Kjeldahl Digestion Block with Scrubber

带酸雾吸收的自动凯氏消解仪

  • KJS-0002
  • Kjeldahl Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Positions:
12–40 tubes
Tube volume:
250 mL or 400 mL
Temperature range:
Ambient to 450 °C
Temperature stability:
±1 °C
Programmes:
Stored multi-step ramps
Scrubber:
Water, alkali or neutralising solution

An automated Kjeldahl digestion block runs programmed temperature ramps and captures acid fumes in an integrated scrubber. It improves safety and reproducibility for laboratories digesting many food and feed samples each day.

Request a quote
View details

Steam Distillation Unit for Kjeldahl Nitrogen

凯氏氮蒸汽蒸馏装置

  • KJS-0003
  • Kjeldahl Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Distillation capacity:
1–6 tubes per cycle
Alkali dosing:
Automatic, 0–100 mL
Steam rate:
Adjustable, 30–100 percent
Distillation time:
3–6 min per sample
Throughput:
20–40 samples/h
Receiver:
Boric acid or standard acid

A steam distillation unit adds alkali to the digest, distils the released ammonia into a receiver and can titrate it automatically. It is the core of routine Kjeldahl nitrogen and protein determination.

Request a quote
View details

Automated Kjeldahl Nitrogen Analyzer

自动凯氏氮分析仪

  • KJS-0004
  • Kjeldahl Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IQ/OQ documentation (to be confirmed)
Automated steps:
Dosing, digestion, distillation, titration
Digestion temperature:
Up to 420 °C
Cycle time:
4–8 min per sample after digestion
Throughput:
20–60 samples/h
Nitrogen range:
0.1–200 mg N per sample
Repeatability:
RSD ≤ 1 percent

An automated Kjeldahl nitrogen analyzer links digestion, distillation and titration in one controlled workflow and reports nitrogen or protein directly. It suits busy laboratories processing many samples with strict regulatory traceability requirements.

Request a quote
View details

Micro-Kjeldahl Digestion and Distillation System

微量凯氏消解与蒸馏系统

  • KJS-0005
  • Kjeldahl Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Sample mass:
10–100 mg
Tube volume:
50–100 mL
Acid volume:
1–5 mL per sample
Digestion temperature:
Up to 400 °C
Digestion time:
20–60 min
Distillation time:
2–4 min per sample

A micro-Kjeldahl system performs digestion and distillation on small sample masses with proportionally reduced reagent volumes. It suits limited samples, expensive matrices and laboratories aiming to cut their acid waste volumes substantially.

Request a quote
View details

Compare Kjeldahl Systems models

ModelPositionsTube volumeTemperature rangeTemperature stabilityDigestion time
Manual Kjeldahl Digestion BlockKJS-00016–12 tubes250 mL or 400 mLAmbient to 450 °C±2 °C45–120 min depending on matrix
Automated Kjeldahl Digestion Block with ScrubberKJS-000212–40 tubes250 mL or 400 mLAmbient to 450 °C±1 °C30–90 min programmed
Steam Distillation Unit for Kjeldahl NitrogenKJS-0003—————
Automated Kjeldahl Nitrogen AnalyzerKJS-0004—————
Micro-Kjeldahl Digestion and Distillation SystemKJS-0005—50–100 mL——20–60 min

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Kjeldahl Systems work?

The Kjeldahl method converts nitrogen in the sample to ammonium sulfate by heating with concentrated sulfuric acid and a catalyst, usually copper or selenium with potassium sulfate to raise the boiling point. Organic matter is oxidised and the nitrogen is retained as ammonium. The digest is then made alkaline with sodium hydroxide, releasing ammonia, which is steam-distilled into a receiver containing boric acid or a standard acid. The amount of ammonia is determined by titration, and nitrogen content is calculated from the titre. A conversion factor, typically 6.25 for food, 6.38 for milk or 5.7 for wheat flour, converts nitrogen into protein. Blank determinations, catalyst choice and digestion completeness are the main factors that determine accuracy, and the method is the traditional reference for protein content.

Which Kjeldahl Systems variants are available?

  • Manual Kjeldahl Digestion Block — A manual Kjeldahl digestion block heats digestion tubes in a controlled aluminium block for acid digestion of food and feed samples.
  • Automated Kjeldahl Digestion Block with Scrubber — An automated Kjeldahl digestion block runs programmed temperature ramps and captures acid fumes in an integrated scrubber.
  • Steam Distillation Unit for Kjeldahl Nitrogen — A steam distillation unit adds alkali to the digest, distils the released ammonia into a receiver and can titrate it automatically.
  • Automated Kjeldahl Nitrogen Analyzer — An automated Kjeldahl nitrogen analyzer links digestion, distillation and titration in one controlled workflow and reports nitrogen or protein directly.
  • Micro-Kjeldahl Digestion and Distillation System — A micro-Kjeldahl system performs digestion and distillation on small sample masses with proportionally reduced reagent volumes.

How do I choose the right variant?

Choose the scale of the system from your sample numbers and the accuracy you need. Manual digestion blocks with six to twelve positions suit low-throughput laboratories and teaching use but demand careful timing and fume control. Automated digestion blocks add temperature programming, exhaust scrubbing and unattended runs, which improve safety and reproducibility. Steam distillation units with automatic alkali addition and titration cut operator time and variability and are the core of routine Kjeldahl work. Integrated analyzers link digestion, distillation and titration in one workflow and are convenient where many samples are processed daily. Micro-Kjeldahl systems use smaller sample and reagent volumes, which reduces waste and is useful when sample material is limited. Whatever the scale, confirm recovery with reference materials.

Where are Kjeldahl Systems used?

Kjeldahl Systems are specified in reference protein determination in food and feed, milk and dairy nitrogen testing, cereal, flour and grain protein measurement, water, wastewater and soil nitrogen analysis, calibration and validation of rapid protein methods and dispute resolution and referee analysis.

Which standards and certifications apply?

Work with Kjeldahl Systems is commonly governed by ISO 1871, ISO 8968-1, ISO 5983-2, AOAC 2001.11, AOAC 920.87 and ISO/IEC 17025. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Kjeldahl work involves concentrated sulfuric acid, hot sodium hydroxide and noxious fumes, so a fume hood, an exhaust scrubber and acid-resistant surfaces are required, along with gloves, goggles and a face shield. Digestion must be complete and free of charring; adding hydrogen peroxide or using a catalyst mixture helps, and selenium catalysts need careful handling because of toxicity. The distillation apparatus must be steam-tight and conditioned before the first sample to avoid low recoveries, and blank values should be subtracted for each batch. The standard acid and sodium hydroxide solutions need regular standardisation, and titrators should be checked with certified materials. Document temperatures, times, reagent batches and catalyst lots.

Frequently asked questions about Kjeldahl Systems

It is the traditional reference method accepted by pharmacopoeias, food regulations and feed standards, and it is robust across many matrices. Its direct acid digestion step also makes it suitable for referee analysis and for validating faster combustion methods.

Need help specifying Kjeldahl Systems?